C190H

C190H

C190H

Product catalog summary
Overview: The C190H Air Permeability Tester is designed for testing the gas permeability of battery diaphragms, breathable membranes, and related polymer materials, as well as cigarette paper and various papers. It uses a volume method for precise and automatic measurements.
Product Features:
  • Volume Method: Automatically determines gas volume passing through specimens, replacing manual methods. Features high-precision pressure control with accuracy better than 0.01kPa.
  • Three-cell Design: Allows testing of three specimens simultaneously or independently, with a fast test mode reducing total test time to one minute.
  • Automatic Specimen Clamping: Pneumatic clamping for consistent force and better sealing, with anti-pinch design for safety.
  • Intelligent Control: Operated via a 12-inch Windows tablet, featuring a high-end industrial computer for reliability and data security. Supports multi-unit display and optional software functions like multi-level authority management.
Test Principle: Measures the time required for 100mL of air to pass through a diaphragm under specific conditions (temperature, humidity, pressure).
Reference Standards: ISO 5636, TAPPI T460, GB/T 36363-2018, GB/T 458-2008, GB/T 23227, GB/T 12655.
Applications:
  • Basic Applications: Suitable for battery diaphragms, breathable membranes, and related polymers.
  • Extended Applications: Suitable for cigarette paper and other papers (customized).
Technical Parameters:
  • Test Scope: s/100 mL: 30-1500, um/(Pa·s): 0.1-4.
  • Volume Resolution: 0.001 mL, Volume Accuracy: 1%.
  • Pressure Range: 0-2 kPa, Pressure Accuracy: 0.01 kPa.
  • Specimen Size: ≥2” x 2” (6cm×6cm), Thickness: ≤120 Mil (3mm).
  • Gas Specifications: Dry air, user-provided air source.
  • Dimensions: 23.6” H x 19.6” W x 27.5” D, Weight: 40 lbs (18 kg).
Product Configuration:
  • Standard: Includes mainframe, tablet, software, and polyurethane pipe.
  • Options: Air compressor, CFR21Part11, GMP Computer System Requirements, DataShieldTM Data Shield.
Notes: Specifications and appearance may change without notice. The company reserves the right to modify and interpret the product details.
See more

Catalog excerpts

C190H-1

C190H Air Permeability Tester applies volume method, and is professionally applicable to the gas permeability test of battery diaphragm, breathable membrane and related polymer materials, as well as the gas permeability test of cigarette paper and various papers. Product Features Note 1 Volume Method, Fully-automatic & Highly Precise Gas volume passing through the specimen is fully-automatically determined, replacing the traditional manual sliding cylinder gas volume measurement method. Fully-automatic high-precision pressure control technology; the pressure accuracy is better than 0.01kPa. Test pressure can be set freely by software. Three-cell Design, Flexible & Efficient Three-independent-testing-cell design can accomplish tests for threes specimens in a single test. Three-cell independent test and three-cell joint test can be selected freely. Fast test mode is provided, and the total test time of three cells is reduced to 1 minute. Automatic Specimen Clamping, Safe & Labor-saving Pneumatic specimen clamping saves time and labor, with consistent clamping force and better sealing. Anti-pinch design and safer operation. Intelligent Control, Convenient & Reliable 12 inch tablet of Windows system is installed for more convenient control. Embedded unique high-end Labthink industrial computer eliminates system failures caused by computer viruses and ensures operation reliability and data storage security. Core sensor and pneumatic control system are from world-renowned manufacturers, with low failure rate and long service life. Automatic detection of temperature and humidity of test environment; automatic record of the test conditions. The instrument supports multi unit display, such as s/100 mL and um/(Pa· which is applicable to the s), detection requirements of different standards. Software has functions such as multi-level authority management and

 Open the catalog to page 1
C190H-2

Test Principle In the test temperature, humidity and atmospheric pressure, the instrument tests the time required for 100mL air passing through the diaphragm with an area of 6.45cm2 under the pressure of 1.21kPa. Reference Standards Note 1 ISO 5636, TAPPI T460, GB/T 36363-2018, GB/T 458-2008, GB/T 23227, GB/T 12655 Applications Note 1 Basic Applications It is suitable for testing the gas permeability of various materials such as battery diaphragms, breathable membranes and related polymer products Extended Applications It is suitable for testing the gas permeability of cigarette paper and other...

 Open the catalog to page 2
C190H-3

Specimen Thickness Test Area Dry air (air source is provided by the user) Interface Size Table 3: Product Configuration Standard Configuration Options Notes Instrument mainframe, tablet, professional software, and Φ6 mm polyurethane pipe Air compressor, CFR21Part11, GMP Computer System Requirements, DataShieldTM Data ShieldNote 3 Compressed air inlet of the instrument is Φ6 mm polyurethane pipe (with pressure of 87PSI/600 kPa); air source is provided by the user. Note 1: the Reference Standards, Applications and Product Features are subject to the specific information in the "Technical Parameters"....

 Open the catalog to page 3

All Labthink Instruments Co., Ltd. catalogs and technical brochures

  1. C610M

    3  Pages

  2. C690H

    4  Pages

  3. C130H

    4  Pages

  4. COF-P01

    2  Pages

  5. VAC-V2

    3  Pages

  6. C230H (2025)

    4  Pages

  7. C610H

    3  Pages

  8. C206H

    4  Pages

  9. C406H

    5  Pages

  10. C403H

    5  Pages

  11. C 681M

    1  Page

  12. C660B (2025)

    3  Pages

  13. C632M

    3  Pages

  14. C630H

    3  Pages

  15. C620H

    3  Pages

  16. C 640

    4  Pages

  17. C 660M

    3  Pages

  18. C306H (2025)

    4  Pages

  19. C203H

    4  Pages

  20. BTY-B3P

    2  Pages

  21. C360M

    4  Pages

  22. C632B

    3  Pages

  23. C390H

    4  Pages

  24. C360H

    4  Pages

  25. C660M

    3  Pages

  26. C303H

    4  Pages

  27. C106H

    5  Pages

  28. C640

    4  Pages

  29. MXD-02

    2  Pages

  30. CHY-C2A

    2  Pages

  31. C611B

    2  Pages

  32. CH130

    4  Pages

  33. C 631 H

    2  Pages

  34. C660 B

    3  Pages

  35. VAC-VBS

    3  Pages

  36. XYD-15K

    2  Pages

  37. C360

    4  Pages

  38. C631 H

    2  Pages

  39. FST-02

    2  Pages

  40. C681 M

    2  Pages

  41. C230

    4  Pages

  42. C631H

    2  Pages

  43. C612M

    3  Pages

  44. SLY-SI

    2  Pages

  45. C360 M

    4  Pages

  46. C611M

    2  Pages

  47. C330H

    4  Pages

  48. Leak Tester

    3  Pages

  49. Tensile Testers

    19  Pages

  50. FDI-01

    5  Pages

  51. DIN 75201

    2  Pages

  52. Abrasion Test

    2  Pages

  53. Torque Meter

    2  Pages

  54. Leak Detector

    2  Pages

  55. Torque tester

    2  Pages

  56. Impact tester

    2  Pages

  57. Gas Analyzer

    2  Pages

  58. TOQUE TESTER

    1  Page

Archived catalogs

  1. C611M

    2  Pages

  2. C306H

    3  Pages

  3. C230H

    4  Pages

  4. Leak Tester

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.