Catalog excerpts
Dual process input meterType series PH1410Features Techn. Data ■ Indication and control of flow, level, differential pressure and others ■ 5-digit 0.56" red sunlight readable display ■ 2 input channels, galvanic isolated ■ Supply 2 x 18 V DC, max. 90 mA per channel ■ Input signal 0 to 20 mA or 0 to 10 VDC ■ Optional plug-in cards: 2 or 4 set points, analog output 0/4...20 mA, 0...10 V ■ Math function on 2 input channels, e.g. as diff. indicator ■ Quick programming mode ■ Add up, min-/max values, 16 step liniearization ■ IP 65 sealed front bezel The dual process input meter PH1410 offers many features and performance capabilities to suit a wide range of industrial applications. The meter has the capability to accept two, 0 to 20 or 0 to 10 VDC signals. In addition, a math function can be performed on the two signals. This unit is rated for NEMA 4X/IP65 outdoor use. The optional plug-in output cards allow the opportunity to configure the meter for current applications, while providing easy upgrades for future need. input (range) Sensor inputs impedance max. contin. display compliance overload resolution Display 5 digit, 0.56" (14.2 mm) variable intensity red sunlight readable Units label kit Each meter has a units indicator with backlighting that can be customized using the units label kit. The backlight is controlled in the programming. Power PH1410-A1: 85 to 250 VAC 50/60Hz, 15VA. PH1410-A2: 11 to 36 VDC, 11 W or 24 VAC +/-10%,15 VA. Transmitter power 18 VDC, +/-20%, unregulated, 70 mA max. per input channel Update rates A/D conversion rate: adjustable 5.3 to 105 readings/sec. Step reponse 60 msec. within 99 % of final readent value up to max. 770 msec. Low frequency noise rejection NMR > 60 dB bei 50/60Hz +/-1 % (can be increased with digital filter). Annunciators A programmable display SP1 setpoint alarm 1 is active SP2 setpoint alarm 2 is active SP3 setpoint alarm 3 is active SP4 setpoint alarm 4 is active Keypad 3 programmable function keys, 5 keys total
Open the catalog to page 1Protection IP 65 sealed front bezel El. connection screw-clamp terminals Humidity 0 to 85 % max. RH non-condensing Ambient tmeperature Operating temperature range: 0...+50°C (0 to 45 °C with all three plugin option cards installed) EMC - noise immunity according to EN50082 section 2 - emitted interference according to EN 50081 section 2 for industrial areas, only Weight approx. 295 g (without plug-in options) Scope of delivery panel gasket and mounting clip included Output cards The optional plug-in output cards allow the opportunity to configure the meter for current applications, while...
Open the catalog to page 2All LABOM Mess- und Regeltechnik GmbH catalogs and technical brochures
-
Thermowells
4 Pages
-
Heat sink compound
1 Pages
-
IO-LINK GOES HYGIENIC
4 Pages
-
Folder PASCAL Ci4 series
6 Pages
-
Inline unit ASEPTconnect
3 Pages
-
Type series DL3../DL4..
4 Pages
-
Bourdon tube pressure gauge
6 Pages
-
Type series BD32../BD33
3 Pages
-
series DL9014
3 Pages
-
IP 69K
1 Pages
-
Folder_IO-Link
2 Pages
-
Brochure en
6 Pages
-
Bourdon tube pressure gauge
5 Pages
-
TYPE SERIES PH1520
2 Pages
-
TYPE SERIES PA2100
3 Pages
-
TYPE SERIES CI4350
17 Pages
-
TYPE SERIES HP1100
4 Pages
-
TYPE SERIES FA2400
6 Pages
-
TYPE SERIES GA2700
3 Pages
-
TYPE SERIES DA1120
4 Pages
-
TYPE SERIES BA5100 ECONOMIC
3 Pages
-
TYPE SERIES BA4100
4 Pages
-
Movement damping
1 Pages
-
Protection Class IP 69K
1 Pages
-
Diaphragm seals brochure
32 Pages
-
Highlights 2018
2 Pages
-
Short form catalogue
36 Pages
-
LABOM Hygienic brochure
20 Pages