TYPE SERIES GA2700-1

Resistance thermometer MiniThermfor general application, Type Series GA270. Features ■ Resistance thermometer for direct temperature measurement on tanks and pipes ■ Compact design ■ High measurement accuracy ■ Output signal: ■ Pt 100, 3-wire technology ■ 4...20 mA, 2-wire technology ■ Fast response ■ Circular connector M12 Options ■ Explosion protection ■ Classification per SIL 2 ■ Output signal 4...20 mA via programmable transmitter ■ Pt 100, 4-wire technology ■ Thermowell with reduced tip 0 4 mm Application area ■ General application The resistance thermometer MiniTherm is suited for tempe- ■ Machinery and tank construction rature measuring in tanks and pipes. Because of its compact ■ Water and wastewater systems design MiniTherm is suitable for use in a great number of ■ Plant engineering technological processes. Mechanical design The Pt 100 is integrated directly into a thermowell. Various types of process connections are available. Electrical connection circular connector with screw connection M12. Further electrical connections upon request. Degree of protection: IP 67 per DIN EN 60529 Temperature detecting element ■ thermowell 0 6 mm option: reduced tip 0 4 mm length see order code. Upon request a calculation for thermowells can be made (for static or dynamic application) with certificate. Measuring resistor 1 x Pt 100, tolerances per class A per DIN EN 60751 Output signal ■ Pt 100, 3- or 4-wire technology (internal connected, see connection diagram) ■ 4...20 mA , 2-wire technology, programmable, option ■ auxiliary power 8.5.36 V DC ■ max. load (U-8.5 V)/0.023 A ■ overrange 3.6.23 mA, infinitily adjustable ■ error signal (following sensor breakage) 3.6.23 mA, infinitily adjustable ■ damping time 0.30 s ■ accuracy at 23 °C < 0.1 % of span temperature effect < 0.13 %/10 °C. Further technical data see type series PA2430, data sheet T4-082-1. Temperature ranges ambient temperature -40...+85 °C allowed storage temperature -40...+85 °C Process connections designs see order code. Gasket is not included ! Further process connections upon request. Operating pressure max. 40 bar Materials wetted parts stainless steel mat.-no. 1.4404 (316L) Functional safety per EN 61508, classification per SIL 2 ; without transmitter, only Response time per DIN EN 60751, test procedure with flowing water (without transmitter) ■ thermowell 6 mm: T 90 = 5.5 s ■ thermowell with reduced tip 4 mm: T 90 = 4.5 s Ex-approval TUV 08 ATEX 554093 X © II 1G Exia IIC T6/T5/T4 © II 2G Ex ib IIC T6/T5/T4 ©II ID Ex iaD 20 T89°C ©II 2D ExibD 21 T129°C U < 30 V I P. < 200 mW i Ci and Li negligible small (not available with transmitter)

 Open the catalog to page 1
TYPE SERIES GA2700-2

design with transmitter process connection diagramed with circular connector Ml2x1

 Open the catalog to page 2
TYPE SERIES GA2700-3

standard option - please give additional specifications for models not listed - LABOM Mess- und Regeltechnik GmbH • Im Gewerbepark 13 • 27798 Hude • Germany Tel. +49 4408 804-0 • Fax +49 4408 804-100 • e-mail: [email protected] • ww

 Open the catalog to page 3

Archived catalogs

  1. Brochure en

    6  Pages

  2. IP 69K

    1  Page

  3. series DL9014

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.