Options ■ Approvals/Certificates - Explosion protection (ATEX) for mechanical devices - Certificate of measuring equipment for Russian Federation - Calibration certificate as per EN 10204 ■ Case with liquid filling ■ Connection to zone 0 with thermowells (upon request) Application These thermometers are suitable for use outdoors and in aggressive environments. The devices can also be supplied with additional liquid damping for use in extreme conditions. Suitable thermowells see product group T5. Application area ■ Shipping ■ Machinery construction ■ Chemical and petrochemical industry ■ General process technology Technical data Constructional design / case High quality case with bajonet ring, material: stainless steel mat.-no. 1.4301 (304) Nominal size: NS 100 or NS 160 Filling: For damping the whole measuring system. Depending on measuring range: Labofin (from -40 °C...100 °C) or silicone oil (from -110 °C...250 °C) Case seal: Material gasket: NBR Window: Non-splintering laminated glass. Option: Non-splintering plastic (Macrolon) Pointer shaft: Stainless steel mat.-no. 1.4571 (316Ti), with plastic bearing With highly flexible joint helix for thermometers with adjustable angel stem Scale: Pure aluminium, white with black inscription Pointer: Pure aluminium, black with adjustment for zero point correction
Open the catalog to page 1Bottom connection NS 100: without filling: without filling: approx. 0.8 kg with filling: approx. 1.5 kg Nominal range Nominal range -40 °C...500 °C (EN 13190): (with restrictions also 600 °C), see order details. Further nominal ranges from -110 °C up to 600 °C (no normal range) upon request. Temperature ranges Ambient: Per EN 13190. Ambient temperatures that deviate from EN are to be specified. without filling: approx. 0.9 kg with filling: approx. 1.0 kg -20.60 °C Further temperature ranges upon request. Process connection Design: ■ rigid temperature detecting element,...
Open the catalog to page 2Dimensions bottom connection The sensitive portion I2 shall reach the media temperature completely. The insertion length l1 should have adaquate size.
Open the catalog to page 3The sensitive portion I2 shall reach the media temperature completely. The insertion length l1 should have adaquate size. shanks, fixed shanks
Open the catalog to page 4LABOM Mess- und Regeltechnik GmbH Im Gewerbepark 13 27798 Hude Germany Phone: +49 (0) 4408 804-0 Fax: +49 (0) 4408 804-100 e-mail: info@labom.com www.labom.com
Open the catalog to page 5Order code (example): FA2300 - A2524 - D1107 - F6 - ... 1 nominal range or measuring range not available with case filling 2 standard insertion length to be specified in order code, e.g. 0 d5= 6 mm, l1 = 100 mm: order code F6100 3 within the temperature limits according to Ex instruction XA_005 4 not for devices with Ex-protection LABOM Mess- und Regeltechnik GmbH Im Gewerbepark 13 27798 Hude Germany Phone: +49 (0) 4408 804-0 Fax: +49 (0) 4408 804-100 e-mail: info@labom.com www.labom.com
Open the catalog to page 6All LABOM Mess- und Regeltechnik GmbH catalogs and technical brochures
-
Thermowells
4 Pages
-
Heat sink compound
1 Pages
-
IO-LINK GOES HYGIENIC
4 Pages
-
Folder PASCAL Ci4 series
6 Pages
-
Inline unit ASEPTconnect
3 Pages
-
Type series DL3../DL4..
4 Pages
-
Bourdon tube pressure gauge
6 Pages
-
Type series BD32../BD33
3 Pages
-
series DL9014
3 Pages
-
IP 69K
1 Pages
-
Folder_IO-Link
2 Pages
-
Brochure en
6 Pages
-
Bourdon tube pressure gauge
5 Pages
-
TYPE SERIES PH1520
2 Pages
-
TYPE SERIES PA2100
3 Pages
-
TYPE SERIES PH1410
2 Pages
-
TYPE SERIES CI4350
17 Pages
-
TYPE SERIES HP1100
4 Pages
-
TYPE SERIES GA2700
3 Pages
-
TYPE SERIES DA1120
4 Pages
-
TYPE SERIES BA5100 ECONOMIC
3 Pages
-
TYPE SERIES BA4100
4 Pages
-
Movement damping
1 Pages
-
Protection Class IP 69K
1 Pages
-
Diaphragm seals brochure
32 Pages
-
Highlights 2018
2 Pages
-
Short form catalogue
36 Pages
-
LABOM Hygienic brochure
20 Pages