video corpo

Type series DL3../DL4..

Type series DL3../DL4..

Type series DL3../DL4..

Product catalog summary
Application Area
Diaphragm seals are primarily used in the food, pharmaceutical, and biotechnology industries for pressure measurement without dead zones.
Features
  • Flush-mounted stainless steel diaphragm, laser welded.
  • Volume optimized diaphragm base.
  • Clamp connection compliant with DIN 32676 and EHEDG certified.
  • Various system fillings for different applications.
  • Multiple measuring device connection options: directly welded, screwed, with temperature decoupler, or with capillary.
Options
  • Material certificate according to EN 10204-3.1.
  • Electropolishing of wetted parts.
  • Hygienic design with advanced surface quality.
  • Special materials available upon request.
Technical Data
  • Construction: Volume reduced diaphragm base made of stainless steel (1.4404/1.4435).
  • Diaphragm: Flat, made of stainless steel (1.4435).
  • Process Connection: Clamp connection per DIN 32676 and ISO 2852.
  • Hygienic Design: Wetted surfaces comply with EHEDG Doc.8 and ASME BPE SF3, with specific surface roughness values guaranteed.
Temperature Error
Detailed error calculation available upon request to optimize the system.
Installation Instructions
Operation outside permissible nominal pressure range requires suitable clamping rings. Refer to DIN 32676 for temperature resistance.
Dimensions and Weight
Detailed dimensions and weights for various clamp connections are provided in tables, specifying nominal diameter (DN), pressure (PN), and other relevant measurements.
Order Details
Includes various diaphragm seal types and configurations, with options for surface roughness, measuring device connections, capillary lengths, and system fillings. Additional features like material certificates and electropolishing are available.
See more

Catalog excerpts

Type series DL3../DL4..-1

Diaphragm seal clamp connection per DIN 32676, ISO 2852 Type series DL3../DL4.. Application area ■ Food industry ■ Pharmaceutical industry ■ Biotechnology Features ■ Flush-mounted separating diaphragm of stainless steel, laser welded ■ Volume optimised diaphragm base ■ Clamp connection per DIN 32676 with EHEDG certificate ■ System fillings for different applications ■ Measuring device connection: - directly welded - directly screwed - with temperature decoupler - with capillary Options ■ Certificates - Material certificate acc. to EN 10204-3.1 ■ Electropolishing (wetted parts) ■ Hygienic design with advanced surface quality ■ Special materials upon request Application Suitable for mounting to bourdon tube pressure gauges and pressure transmitters. The diaphragm seal with clamp connection is used mainly for dead-zone free pressure measurement. Constructional design Basic body: Volume reduced diaphragm base Material: stainless steel mat.-no. 1.4404/1.4435 (316L) Diaphragm: Flat diaphragm Material wetted Diaphragm: parts: Stainless steel mat.-no. 1.4435 (316L) Further materials upon request Basic body: Stainless steel mat.-no. 1.4404/1.4435 (316L) Process connection Design: Clamp connection per: ■ DIN 32676 ■ ISO 2852 Nominal pressure/ See table nominal width: The sealing is not included in the scope of delivery. Measuring device connection See order details. Material stainless steel mat.-no. 1.4301 (304) System filling See order details; further upon request. Further details about pressure transmission fluids see general technical information TA_038. Hygienic design The wetted surfaces made of stainless steel are executed according to EHEDG Doc.8 and ASME BPE SF3. In case of choosing the additional feature HY, we guarantee the following surface roughness values: Diaphragm foil: Ra < 0.38 pm Further versions of hygienic design upon request. Data sheet D5-026_2019-04_10.00 Page 1/4 LABOM Mess- und Regeltechnik GmbH Im Gewerbepark 13 27798 Hude Germany Hotline: +49 4408 804-444 Fax: +49 4408 804-100 e-mail: [email protected] www.labom.com

 Open the catalog to page 1
Type series DL3../DL4..-2

Temperature error In order to optimise the system we provide a detailed error calculation upon request. Weight See table. Installation instructions For diaphragm seals with clamp design an operation outside the permissible nominal pressure range is only permitted when using suitable clamping rings. Please note DIN 32676 on temperature resistance. Further information about diaphragm seals see general technical information TA_031. Measuring device connection Data sheet D5-026_2019-04_10.00 Diaphragm seal

 Open the catalog to page 2
Type series DL3../DL4..-3

Clamp connection per DIN 32676 model A (metric) for pipes per EN 10357 (DIN 11850) Clamp connection per DIN 32676 model B (OD/ISO) for pipes per DIN EN ISO 1127 Data sheet D5-026_2019-04_10.00 Diaphragm seal

 Open the catalog to page 3
Type series DL3../DL4..-4

Order code (example): DL3200 - A4007 - L22 - ... 1 aseptic connection per Sudmo upon request 2 EHEDG certified only in connection with hygienic design (order code option HY) 3 EHEDG certificate valid only if gaskets are used that are listed in the "EHEDG position paper" 4 for more detailed information about pressure transmission fluids see TA_038. Please state temperature range to allow an accurate calculation of the system. 5 max. media temperature for pressures > 0 bar rel. Data sheet D5-026_2019-04_10.00 Diaphragm seal

 Open the catalog to page 4

Archived catalogs

  1. Brochure en

    6  Pages

  2. IP 69K

    1  Page

  3. series DL9014

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.