Product catalog summary
Application Area: The PASCAL Ci4 Delta P differential pressure transmitter is suitable for general process engineering, chemical and petrochemical industries, power generation, environmental engineering, and water/wastewater management.
Features: Key features include a diaphragm seal, simultaneous display of differential and static pressure, high reference accuracy of 0.07%, long-term stability of 0.1% over 5 years, and a nominal range from 100 mbar to 16 bar. It supports a turndown ratio of up to 100:1, is housed in a stainless steel case with IP 65/67 protection, and offers a high-resolution display with comprehensive parameterizing, simulation, and diagnostic functions. Digital communication is supported via the HART protocol.
Options: Options include explosion protection, SIL2 classification, various certificates, and a removable display unit. The device can handle a maximum working pressure of 400 bar upon request.
Technical Data: The transmitter supports a wide range of measuring spans and static pressures, with a minimum permissible static pressure of 5 mbar abs. It is constructed with stainless steel materials, offers various electrical connections, weighs approximately 2.9 kg, and features a laser-marked type plate.
Accuracy and Influence: The device maintains high accuracy under specified conditions, with a reference accuracy of ≤ ± 0.07% for nominal ranges. It accounts for temperature influences and static pressure effects, ensuring reliable performance.
Output and Communication: The transmitter operates on a 4-20 mA signal with HART protocol, supporting linear, inverse, square root, and table functions. It offers a measuring rate of 50 Hz and a resolution of 0.5 µA.
Temperature Ranges: The device operates in ambient temperatures from -40 to 80°C, with media temperatures ranging from -90 to 400°C.
Certifications: The transmitter is ATEX and IECEx approved for explosive environments and complies with EMC standards per EN 61326-1.
Parameterization and Diagnostics: The device allows extensive parameterization, including setting range values, damping, and display configurations. It features diagnostic functions for self-checks and process diagnostics.
Connection and Dimensions: Detailed diagrams and dimensions are provided for various connection types, including capillary and direct connections, with specifications following EN and ASME standards.
Specifications: Detailed specifications for various LABOM products are provided, including remote display and control units, pressure and level transmitters, and diaphragm seals. Key specifications include dimensions, mounting options, material compositions, and pressure ratings. The PASCAL Ci4 Delta P transmitter is highlighted for its high overload protection and various nominal ranges from 100 mbar to 16 bar, with static overload protection up to 160 bar.
Procedures: Instructions for mounting and installation are provided, including wall and pipe-mounting angles and the use of oval flanges. The document specifies the use of stainless steel materials for durability and includes details on electrical connections and cable gland specifications.
Standards and Certifications: Compliance with several standards is referenced, including EN 1092-1, ASME B16.5, and EN 61508 for functional safety. ATEX and IECEx certifications for explosion protection are mentioned, indicating suitability for hazardous environments.
Recommendations: Recommendations include selecting appropriate materials and configurations based on environmental conditions, such as temperature and pressure. The document advises on the use of synthetic oils for system filling and provides options for different ambient temperature ranges.
Additional Features: Optional features include software for level applications, material and calibration certificates, and functional safety classifications. Various process connection variations and diaphragm seal configurations are detailed.
Accessories: Accessories such as mounting angles, oval flanges, and wall brackets are available to complement the main products, facilitating installation and ensuring secure mounting.
See more

Catalog excerpts

TYPE SERIES CI4350-1

Differential pressure and level transmitterPASCAL Ci4 Delta P, highly overload protected,Type series CI4350Features Application area ■ General process engineering ■ Chemical industry ■ Petrochemical industry ■ General process technology ■ Power generation ■ Environmental engineering ■ Water / wastewater ■ Differential pressure transmitter with diaphragm seal ■ Simultaneous display of differential pressure and static pressure ■ Reference accuracy 0.07 % ■ Long-term stability 0,1 % within 5 years ■ Nominal ranges 100 mbar to 16 bar ■ Turndown up to 100:1 ■ Stainless steel case in sturdy design, degree of protection IP 65/67 ■ High-resolution display with intuitive 4-button operation and backlight ■ Comprehensive parameterising functions ■ Comprehensive simulation and diagnostic functions ■ Quick access to device data ■ Development according to SIL2 ■ Maximum working pressure 160 bar ■ Measuring rate up to 50 Hz ■ Output signal 4...20 mA with HART® protocol ■ Media temperature -90.400 °C ■ Configuration memory ■ Digital communication via PDM, FDT/DTM, 375/475 Field Communicator ■ Output functions: linear, invers, square root, table function with up to 64 support points ■ Wetted parts stainless steel ■ EAC declaration (upon request) Options ■ Approvals/Certificates - Explosion protection for gases and dust - Classification per SIL2 (in preparation) - Certificate of measuring equipment for Russian Federation - Material certificate per EN 10204 - Calibration certificate per EN 10204 ■ Operating software LAB4Level for intuitive parameterisation of level measurements ■ Removable display and control unit ■ Degree of protection IP 69K ■ Maximum working pressure 400 bar (upon request) Application The digital differential pressure transmitter PASCAL Ci4 Delta P with diaphragm seal is suitable for pressure measurement of aggressive, high viscous and high-temperature media. Also available as an option is the operating software LAB4Level that allows the measuring of filling height, filling volume and filling weight (mass).

 Open the catalog to page 1
TYPE SERIES CI4350-2

Measuring ranges Up to a turndown of 100:1 the measuring span can be freely selected. Nominal range Minimum permissible static pressure: 5 mbar abs (at reference conditions) Constructional design / case Design: Material case: Material front cover: Gaskets: Degree of protection per EN 60529: Climatic category per EN 60721 3-4: Vibration resistance per EN 61298-3: Material window: Two-chamber case, continously rotatable by ± 170° Case surface blasted ■ Stainless steel mat.no. 1.4301/1.4305 (304/303) ■ Stainless steel mat.no. 1.4404 (316L) ■ Stainless steel mat.no. 1.4305 (303) ■ Stainless steel...

 Open the catalog to page 2
TYPE SERIES CI4350-3

Calibration position: Temperature influence of ambient temperature: Configuration memory: Long-term drift: Refer to nominal range ■ High-resolution graphic display with backlight ■ 4-button operation ■ Freely configurable display modes ■ continuously rotatable by ± 170 (detent every 90°) ■ Optional: Remote display and control unit, can be used up to 10 m away from measuring point ■ All parameterisation data can be copied from the device into the configuration memory in the display module. The data is permanently stored there, even in the event of power failure. ■ The parameters can be transferred simply...

 Open the catalog to page 3
TYPE SERIES CI4350-4

Temperature ranges Turndown: Damping: Measuring rate: 2-wire technology Lower limit Upper limit Lower alarm current Upper alarm current Current limitation Operational availability Response time tg0 at current output Digitale communication Communication via: ■ Siemens PDM ■ Pactware or compatible systems (FDT/DTM) ■ 375 / 475 Field Communicator ■ linear ■ inverse response ■ by square root ■ table function with up to 64 support points max. 100:1 0.999.9 s selectable in steps of 0.1 s 50 Hz Current 3.55.21.5 mA selectable in steps sensing func. of 0.001 mA Load R: R < (U-12V DC)/0.022 A [Q]...

 Open the catalog to page 4
TYPE SERIES CI4350-5

1The static pressure will be displayed as absolute pressure by default, adjusted to 0 bar abs.

 Open the catalog to page 5
TYPE SERIES CI4350-6

Diagnostic functions Output (2-wire): 4...20 mA Circular connector M12 x 1 Data sheet D4-071-4 Rev. 1E8

 Open the catalog to page 6
TYPE SERIES CI4350-7

Electrical connection cable gland Capillary connection double-sided (see order code variation A) Capillary connection plus-sided (see order code variation B)

 Open the catalog to page 7
TYPE SERIES CI4350-8

Direct connection plus-sided with distance tube (see order code variation C) Direct connection plus-sided with distance tube, capillary connection minus-sided (see order code variation D) Process connections Cell diaphragm seal Dimensions (mm) following ASME B 16.5 Optionally available with extended diaphragm

 Open the catalog to page 8
TYPE SERIES CI4350-9

Optionally available with extended diaphragm

 Open the catalog to page 9
TYPE SERIES CI4350-10

Remote display and control unit (Type series MC1140) Mounting angle for wall and pipe-mounting (Type series MM1500) Oval flange (Type series MC1060) All dimensions are in mm Data sheet D4-071-4 Rev. 1E8

 Open the catalog to page 10
TYPE SERIES CI4350-11

1 requires front cover of stainless steel 2 not for devices with Ex marking LABOM Mess- und Regeltechnik GmbH Im Gewerbepark 13 27798 Hude Germany Phone: +49 4408 804-0 Fax: +49 4408 804-100 e-mail: [email protected] www.labom.com

 Open the catalog to page 11
TYPE SERIES CI4350-12

LABOM Mess- und Regeltechnik GmbH Im Gewerbepark 13 27798 Hude Germany Phone: +49 4408 804-0 Fax: +49 4408 804-100 e-mail: [email protected] www.labom.com

 Open the catalog to page 12
TYPE SERIES CI4350-13

LABOM Mess- und Regeltechnik GmbH Im Gewerbepark 13 27798 Hude Germany Phone: +49 4408 804-0 Fax: +49 4408 804-100 e-mail: [email protected] www.labom.com

 Open the catalog to page 13
TYPE SERIES CI4350-14

Prozessanschluss Variante C: Direct connection plus-sided with distance tube Diaphrag seal plus-sided LABOM Mess- und Regeltechnik GmbH Im Gewerbepark 13 27798 Hude Germany Phone: +49 4408 804-0 Fax: +49 4408 804-100 e-mail: [email protected] www.labom.com

 Open the catalog to page 14
TYPE SERIES CI4350-15

Prozessanschluss Variante D: Direct connection plu-sided with distance tube, capillary connection minus-sided Diaphragm seal plus-sided LABOM Mess- und Regeltechnik GmbH Im Gewerbepark 13 27798 Hude Germany Phone: +49 4408 804-0 Fax: +49 4408 804-100 e-mail: [email protected] www.labom.com

 Open the catalog to page 15
TYPE SERIES CI4350-16

LABOM Mess- und Regeltechnik GmbH Im Gewerbepark 13 27798 Hude Germany Phone: +49 4408 804-0 Fax: +49 4408 804-100 e-mail: [email protected] www.labom.com

 Open the catalog to page 16

Archived catalogs

  1. Brochure en

    6  Pages

  2. IP 69K

    1  Page

  3. series DL9014

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.