Application Area
The diaphragm seal is designed for use in the food, pharmaceutical, and biotechnology industries.
Features
  • Flush-mounted stainless steel diaphragm, laser welded.
  • Volume optimized diaphragm base.
  • EHEDG-certified for hygienic applications.
  • Various system fillings available for different applications.
  • Multiple measuring device connection options: directly welded, screwed, with temperature decoupler, or with capillary.
Options
  • Material certificate according to EN 10204-3.1.
  • Electropolishing of wetted parts for enhanced surface quality.
Technical Data
  • Basic body and diaphragm made of stainless steel (316L).
  • Union nut made of stainless steel (304).
  • Process connection: HYGIENIC Tubus Ø 43.3 mm, diaphragm surface Ø 33 mm, nominal pressure PN 40.
  • Temperature range: -50 to 200 °C.
  • Gasket material: FDA compliant silicone.
Hygienic Design
  • Wetted surfaces comply with EHEDG Doc.8 and ASME BPE SF3 standards.
  • Surface roughness values: Diaphragm foil Ra ≤ 0.38 µm, Laser welds Ra ≤ 0.76 µm, Turned parts Ra ≤ 0.76 µm.
Temperature Error
Detailed error calculation available upon request to optimize the system.
Weight
Approximately 1.0 kg with measuring device connection G1/2.
Order Details
  • Design: HYGIENIC Tubus Ø 43.3 mm.
  • Surface roughness: Hygienic version as per EHEDG Doc.8 and ASME BPE SF3.
  • Basic body material: Stainless steel mat.-no. 1.4404/1.4435 (316L).
  • Diaphragm material: Stainless steel mat.-no. 1.4435 (316L).
  • Gasket: Silicone, FDA compliant, temperature range -50 to 200 °C.
  • Measuring device connection options: Directly welded, screwed, with temperature decoupler, or with capillary.
  • System filling options: Synthetic oil, free of silicone, with specified temperature ranges.
Accessories
  • Weld-in adapter, stainless steel mat.-no. 1.4571 (316Ti), hygienic design.
See more

Catalog excerpts

series DL9014-1

Diaphragm seal for food/pharmaceutical/biotechnologyHYGIENIC Tubus 0 43.3 mm with screwing DN 25, Type series DL9014Features pWT'^0 (eljeoG) Application area ■ Food industry ■ Pharmaceutical industry ■ Biotechnology ■ Flush-mounted separating diaphragm of stainless steel, laser welded ■ Volume optimised diaphragm base ■ EHEDG-certified ■ System fillings for different applications ■ Measuring device connection: - directly welded - directly screwed - with temperature decoupler - with capillary Options ■ Certificates - Material certificate acc. to EN 10204-3.1 ■ Electropolishing (wetted parts) ■ Hygienic design with advanced surface quality Application Suitable for mounting to bourdon tube pressure gauges and pressure transmitters. The diaphragm seal HYGIENIC Tubus is used mainly for dead-zone free pressure measurement. Basic body: Constructional design / case Volume reduced diaphragm base Material: stainless steel mat.-no. 1.4404/1.4435 (316L) Material: stainless steel mat.-no. 1.4301 (304) Flat diaphragm Material wetted Diaphragm: parts: Stainless steel mat.-no. 1.4435 (316L) Basic body: Stainless steel mat.-no. 1.4404/1.4435 (316L) Design: HYGIENIC Tubus: 0 43.3 mm surface: Nominal pres- PN 40 sure: Gasket: Material silicone, FDA compliant Measuring device connection See order details. Material stainless steel mat.-no. 1.4301 (304) System filling See order details; further upon request. Further details about pressure transmission fluids see general technical information TA_038. Hygienic design The wetted surfaces made of stainless steel are executed according to EHEDG Doc.8 and ASME BPE SF3 (Code: HY). We guarantee the following surface roughness values: Diaphragm foil: Ra < 0.38 pm Laser welds: Ra < 0.76 pm Turned parts: Ra < 0.76 pm Further versions of hygienic design upon request. Temperature error In order to optimise the system we provide a detailed error calculation upon request.

 Open the catalog to page 1
series DL9014-2

Weight With measuring device connection G1/2 approx. 1.0 kg Further information about diaphragm seals see general technical information TA 031. directly welded directly screwed temperature decoupler capillary Code: A400 Code: A300 Code:A100 welded Code: B40../B50.. weld-in adapter

 Open the catalog to page 2
series DL9014-3

Order code (example): DL9014 - HY - E7 - G7 - H3 - A400 - L22 - ... 1 for more detailed information about pressure transmission fluids see TA_038. Please state temperature range to allow an accurate calculation of the system. 2 max. media temperature for pressures > 0 bar rel. The temperature range of the used gasket has to be observed. LABOM Mess- und Regeltechnik GmbH Im Gewerbepark 13 27798 Hude Germany Phone: +49 4408 804-0 Fax: +49 4408 804-100 e-mail: [email protected] www.labom.com

 Open the catalog to page 3

Archived catalogs

  1. Brochure en

    6  Pages

  2. IP 69K

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.