Catalog excerpts
Pressure transmitter/Pressure switch PASCAL CSfor food/pharmaceutical/biotechnology, Type series CS2110 Application area ■ Pharmaceutical industry ■ Food industry ■ Biotechnology Features ■ Multifunctional pressure transmitter/pressure switch ■ Hygienic case with no notches or indentations ■ Degree of protection IP 65 ■ 4 digit LED display, can be mirror-imaged by 180° ■ Indication module rotatable by 300° ■ Measuring ranges - 0...100 mbar up to 0...40 bar rel. - 0.1 bar up to 0.6 bar abs. ■ Output signal 4...20 mA, 2-wire technology ■ Accuracy < 0,2 % ■ Easy to program locally (as per VDM standard) ■ Galvanic isolation between transmitter and switching outputs ■ Various process connections with flush mounted diaphragm ■ EAC declaration (upon request) Options ■ Approvals/Certificates - Certificate of measuring equipment for Russian Federation - Material certificate as per EN 10204-3.1 - Calibration certificate as per EN 10204-3.1 - Roughness height rating with inspection certificate acc. to EN 10204-3.1 ■ 2 floating contacts ■ Switching contacts with high switching current (1A) ■ Wetted parts electropolished ■ Electrical connection rotatable by 300° ■ Degree of protection IP 67 ■ Hygienic design Application The pressure transmitter/pressure switch PASCAL CS is suited for measuring the relative and absolute pressures of gases, vapors and liquids. The multifunctional PASCAL CS displays the measurement; outputs a current signal proportional to the pressure. It has two optional contacts. Constructional design / case Design: Hygienic case design, including gasket for seamless design Fully encapsulated electronics unit Material: Stainless steel mat.-no. 1.4301 (304) Indication module: macrolon Pressure com- Aeration via sintered filter pensation: Electrical con- ■ circular connector M12, 4 pin nection: ■ circular connector M12, 8 pin (necessary for devices with switch function) Incl. sealing ring to ensure case is completely sealed Degree of protection per EN 60529: Climatic cate- 4K4H gory per EN 60721 3-4:
Open the catalog to page 1Indication Design: See order details Hygienic design The wetted surfaces made of stainless steel are executed according to EHEDG Doc.8 and ASME BPE SF3 (Code: HY). We guarantee the following surface roughness values: Type: Digit high: Resolution: Accuracy: Temperature-influence: 4 digit, red LED with 7 segments 8.5 mm -9999...9999 digit ± 0,2 % ± 1 digit ± 0,1 %/10K Diaphragm foil: Ra < 0.38 pm Laser welds: Ra < 0.76 pm Turned parts: Ra < 0.76 pm Further versions of hygienic design upon request. Measuring system Sensor: Piezoresistive measuring element System filling:...
Open the catalog to page 2Medium: -20.125° C, short term 140 °C, optional up to 160 °C for 1 h. Higher process temperatures upon request Storage: -40.85 °C Tests and certificates EMC: EMC directives 2014/30/EU ■ EAC declaration upon request ■ Certificate of measuring equipment for Russian Federation Mounting information Mounting position: At choice Calibration position: Vertical Paramerterisation The following parameters can be assigned via 3 keys: Hysteresis functions Hysteresis function Parameterisation see operating instruction BA_060.
Open the catalog to page 38-pin connector (for switching outputs) Explanations (+) plus-side of supply S1/S2 common pin of switching outputs (see below) S1 switching output 1 Dimensions for process temperatures up to 125°C (short period up to 140°C, 1 h) All dimensions are in mm temperature decoupler for process temperatures up to 160°C
Open the catalog to page 4process connection (standard) aseptic screw joint clamp connection collar connection per DIN 32676/ISO 2852 Varivent connection with union nut per DIN 11864-1 type A weld-in adapter see data-sheet D6-037 weld-in adapter see data-sheet D6-037 weld-in adapter see data-sheet D6-037 weld-in adapter see data-sheet D6-037 Clamp connection per DIN 32676 model B (OD, ISO) for pipes per DIN EN ISO 1127 Sanitary pipe connection with union nut per DIN 11851
Open the catalog to page 5LABOM Mess- und Regeltechnik GmbH Im Gewerbepark 13 27798 Hude Germany Phone: +49 4408 804-0 Fax: +49 4408 804-100 e-mail: info@labom.com www.labom.com
Open the catalog to page 6Order code (example): CS2110 - A1086 - N70.1 - T30 - K136 - HY - ... 1 necessary for devices with switching contact 2 further process connections (pressure transmitter) upon request 3 possible for measuring ranges > 250 mbar. For a function calculation and optimim system design it is necessary to specify the operation temperature 4 hygienic design not possible LABOM Mess- und Regeltechnik GmbH Im Gewerbepark 13 27798 Hude Germany Phone: +49 4408 804-0 Fax: +49 4408 804-100 e-mail: info@labom.com www.labom.com
Open the catalog to page 7All LABOM Mess- und Regeltechnik GmbH catalogs and technical brochures
-
Thermowells
4 Pages
-
Heat sink compound
1 Pages
-
IO-LINK GOES HYGIENIC
4 Pages
-
Folder PASCAL Ci4 series
6 Pages
-
Inline unit ASEPTconnect
3 Pages
-
Type series DL3../DL4..
4 Pages
-
Bourdon tube pressure gauge
6 Pages
-
Type series BD32../BD33
3 Pages
-
series DL9014
3 Pages
-
IP 69K
1 Pages
-
Folder_IO-Link
2 Pages
-
Brochure en
6 Pages
-
Bourdon tube pressure gauge
5 Pages
-
TYPE SERIES PH1520
2 Pages
-
TYPE SERIES PA2100
3 Pages
-
TYPE SERIES PH1410
2 Pages
-
TYPE SERIES CI4350
17 Pages
-
TYPE SERIES HP1100
4 Pages
-
TYPE SERIES FA2400
6 Pages
-
TYPE SERIES GA2700
3 Pages
-
TYPE SERIES DA1120
4 Pages
-
TYPE SERIES BA5100 ECONOMIC
3 Pages
-
TYPE SERIES BA4100
4 Pages
-
Movement damping
1 Pages
-
Protection Class IP 69K
1 Pages
-
Diaphragm seals brochure
32 Pages
-
Highlights 2018
2 Pages
-
Short form catalogue
36 Pages
-
LABOM Hygienic brochure
20 Pages