Application area ■ Shipping ■ Machinery construction ■ Chemical and petrochemical industry ■ General process technology Technical data Constructional design / case Design: High quality case with bajonet ring, material: stainless steel mat.-no. 1.4301 Movement: Scale: Case filling: Labofin Further filling liquids upon request. Case seal: Material gasket: NBR Non-splintering laminated glass. Option: non-splintering plastic (Macrolon) with adjustable reference pointer Stainless steel with compensation Pure aluminium, white with black inscription. Alternatively with marking or fixed reference pointer. Pure aluminium, black with micro adjustment for zero point correction
Open the catalog to page 1Bottom or centre back connection NS 100: Per EN 13190. Ambient temperatures that deviate from EN are to be specified. -20.60 °C Further temperature ranges upon request. without filling: with filling: Process connection Design: ■ rigid temperature detecting element, bottom connection. ■ rigid temperature detecting element, centre back connection. ■ rigid temperature detecting element, adjustable angle stem, latching every 20°. Various process connections can be supplied (see order details). Measuring element Measuring Bourdon tube, dead zone free with noble Temperature sensor Temperature- Diameter...
Open the catalog to page 2Dimensions bottom and centre back connection Temperature detecting element diameter d5, insertion length 11 and active length 12 see order details. For nominal ranges > 160 °C dimension increases by 36 mm.
Open the catalog to page 3Dimensional drawing of process connections for bottom connection, centre back connection and adjustable angle stem
Open the catalog to page 4LABOM Mess- und Regeltechnik GmbH Im Gewerbepark 13 27798 Hude Germany Phone: +49 (0) 4408 804-0 Fax: +49 (0) 4408 804-100 e-mail: [email protected] www.labom.com
Open the catalog to page 51 the active length 12 shall reach the media temperature completely. The insertion length 11 should have adequate size. 2 standard insertion length to be specified in order code, e.g. 0 d5= 6 mm, l1 = 100 mm: order code F6100 3 within the temperature limits according to Ex instruction XA_005 4 not for devices with Ex-protection LABOM Mess- und Regeltechnik GmbH Im Gewerbepark 13 27798 Hude Germany Phone: +49 (0) 4408 804-0 Fax: +49 (0) 4408 804-100 e-mail: [email protected] www.labom.com
Open the catalog to page 64 Pages
4 Pages
3 Pages
6 Pages
20 Pages
32 Pages
2 Pages
4 Pages
3 Pages
4 Pages
3 Pages
6 Pages
4 Pages
17 Pages
2 Pages
3 Pages
2 Pages
5 Pages
6 Pages
2 Pages
1 Page
1 Page
3 Pages
1 Page
3 Pages
4 Pages
1 Page
36 Pages
6 Pages