Digital transmitter for temperature lO-Link,for resistance thermometers, Type series PA2530 Application area ■ Pharmaceutical industry ■ Food industry ■ Biotechnology ■ General process technology Features ■ Digital transmitter for temperature with IO-Link V1.1 output signal ■ Data transmission rate COM 3 (230.4 kBaud) ■ Accuracy < 0.1 % ■ Input Pt100 per EN 60751 ■ Nominal range -50...260 °C ■ 2 switching outputs maximum Application The temperature transmitter PA2530 with mit IO-Link is suitable for hygienic temperature measurement in connection with the following resistance thermometers ■ MiniTherm, Type series GA27 (see data sheet T4-014, T4-015 and T4-017) ■ Clamp-on, Type series GA2610 (see data sheet T4-028) Due to its compact design the transmitter fulfils the hygienic requirements of plant and machinery engineering. Constructional design case Design: Hygienic case design Material: Stainless steel mat.-no. 1.4301 (304) Electrical Circular connector M12 (4 pin) Signal: IO-Link device 1.1 (downward compatible to V 1.0) Data transfer rate COM 3 (230,4 kBaud) Min. cycle time: 2 ms ■ 1 switching output ■ Optional: 2 switching outputs Properties switching output Characteristic temperature linear Switching functions configurable: Switching current: ■ Hysteresis function or frame function ■ Normally closed or normally opened contact ■ Output PNP/High-side or NPN/Low-side < 100 mA per output Voltage drop at < 2 V switching transistor: Short-circuit yes (locked) proof: Output Accuracy: < ± 0.1 %, referred to nominal range Temperature < 0.0025 %/K referred to nominal influence range and adjustment point (25°C ± 5 K) Reverse polari- yes ty protected:

Open the catalog to page 1
Digital transmitter for temperature IO-Link - 2

Hysteresis for hysteresis function: for frame function: Fixed settings (symmetrical; ± 0,25 % of the measuring range) switch-off delay: Supply voltage Functional 18...32 V DC * area lO-Link: Functional 9,6...32 V DC * area 2 output signals Nominal 24 V DC voltage: * The auxiliary energy of the pressure sensor must meet SELV requirements; optionally, an energy-limited current circuit according to section 9.3 of EN 610610-1 and UL 61010-1 can be used. Current consumption: In idle mode: < 12 mA (at nominal voltage) lO-Link: < 20 mA (at nominal voltage) 2 switching < 200 mA (at nominal voltage)...

Open the catalog to page 2
Digital transmitter for temperature IO-Link - 3

LABOM Mess- und Regeltechnik GmbH Im Gewerbepark 13 27798 Hude Germany Phone: +49 4408 804-0 Fax: +49 4408 804-100 e-mail: info@labom.com www.labom.com

Open the catalog to page 3
Digital transmitter for temperature IO-Link - 4

Transmitter for temperature IO-Link, for resistance thermometers Type series PA2530 LABOM Mess- und Regeltechnik GmbH Im Gewerbepark 13 27798 Hude Germany Phone: +49 4408 804-0 Fax: +49 4408 804-100 e-mail: info@labom.com www.labom.com