The document introduces the SoFie™ stop flow controller and Laura™ software package by LabLogic, designed to enhance radiochemical measurement. It highlights the system's ability to achieve the lowest limits of detection in the industry, offering a fully automated and compliant solution for radiochemical analysis.

Key Features
  • Accurate counting of low DPM samples with automated, unattended operation.
  • Compatible with all radiochemical detectors, eliminating the need for post-run collection and preparation.
  • Single point control for the complete system, preventing loss of volatile or thermolabile analytes.
  • GxP compliant Laura™ software package with security, audit trail, and electronic signatures.

Specifications
  • Low DPM Measurement: 5-20 DPM/PEAK for 14C, 10-40 DPM/PEAK for 3H.
  • Supported Detectors: β-RAM® Series and other leading detectors.
  • Settable Functions: Fraction Size, Counting Time, Flush/Clean Cycle, Counting Windows.
  • Power Requirements: 110/220v, 50/60 Hz, CE Certified.
  • Dimensions: 17cm x 17cm x 26cm deep, Weight: 5kg.
  • PC Requirements for Laura™: Pentium IV at 1GHz or better, 256 Mb RAM minimum, Windows® OS.

Operational Benefits
  • Replaces time-consuming Liquid Scintillation Counting with optimized counting time in the radiochemical detector flow cell.
  • Eliminates the need for fraction collection and LSC to achieve desired limits of detection.
  • Allows for single point control without the need for additional method development.

Multi-Vendor Compatibility
The Laura™ software package supports over 100 HPLC modules, radiochemical detection, and liquid handling options, ensuring regulatory compliance for pharmaceutical and research organizations.

Conclusion
The SoFie™ and Laura™ system by LabLogic offers a comprehensive solution for radiochemical measurement, providing enhanced detection capabilities, regulatory compliance, and operational efficiency.
See more

Catalog excerpts

SoFie?-1

Enhanced detection for Radiochemical Measurement Accurate counting of low DPM samples Automated analysis, completely unattended operation Lowest Limits of Detection for Radiochemical Measurement Compatible with all radiochemical detectors Single point control for the complete system Prevents loss of volatile or thermolabile analytes Eliminates post run collection, preparation and recounting • No requirement of exporting LSC data for analysis • GxP Compliant Laura™ software package The combination of HPLC separations and Radiochemical detection has been taken to a new level by LabLogic. Analysts can now achieve the lowest Limits of Detection in the industry with the SoFie™ stop flow controller and Laura™ software package. A fully automated system designed, supported and maintained by one company is now available from LabLogic, the leaders in radiochemical detection. SoFie™ is part of the family of LabLogic instruments covering a wide range of analytical tools and software packages which are designed specifically for the handling, measurement and reporting of radionuclides in a wide range of sample types. LabLogic is a lot more than a provider of equipment as we realise that Regulatory Compliance and Validation Services are also required by our customers. Because we are committed to the world of radioactivity we understand customer needs and provide specifically tailored services to meet the ever changing needs of our users. SoFie™, through the industry standard Laura™ software suite, offers Security, Audit Trail and Electronic Signatures which help LabLogic users meet and exceed their compliance requirements.

 Open the catalog to page 1
SoFie?-2

Simplicity SoFie replaces the requirement of time consuming and expensive Liquid Scintillation Counting of low level radionuclides. By using the optimised counting time in the radiochemical detector flow cell, the combination of the SoFie controller module and Laura software allows the radiochemical measurement to be entirely at the threshold and measurement level required by the user. With SoFie the radiochemist simply initiates a Batch analysis and the system does the rest. ™ Low DPM Measurement Typical results are: 5-20 DPM/PEAK For 14C Single Point Control With SoFie there is no requirement...

 Open the catalog to page 2

All Lablogic Systems catalogs and technical brochures

  1. Logi-CHROM

    3  Pages

  2. wiper series

    8  Pages

  3. Scan-RAM

    5  Pages

  4. Tracer-QC™

    5  Pages

  5. Beta-RAM

    8  Pages

  6. Flow-Count

    2  Pages

  7. SoFie™

    2  Pages

  8. Posi-RAM

    4  Pages

  9. β-RAM®

    4  Pages

  10. Chameleon V

    4  Pages

Archived catalogs

  1. Scan-RAM

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.