MIX

MIX

MIX

Product catalog summary

Overview

This document presents technical specifications and features of La Fonte's filtration and pump systems, focusing on the MIX series filter units and associated components. It highlights product options, construction materials, operational principles, and available accessories.

Product Options and Accessories

  • Valves and Controls: Suction valve (a), discharge valve (m), by-pass valve between pump and filter (b), active carbon treatment system valves (c), valve between pump and filter (v), pressure gauge (g).
  • Additional Features: Pre-coat system (t), wheels (w), safe security system (s), splashproof ring (r), splashproof ring with interlock sensor (i).
  • Pump Types: Magnetic drive pumps, vertical pumps, cartridges and discs filter pumps.
  • Other Products: Active carbon columns, precious metals recovery systems (resin and electrolytic), demineralizers, oil skimmers.

Filter Units - MIX Series

The MIX series offers multiprocess filtration and purification systems designed for galvanic bath applications. Key features include:

  • Construction primarily from polypropylene for chemical resistance and mechanical strength.
  • C-PVC lids ensure perfect sealing of the filter chamber.
  • Interchangeable filter media: filter paper (0.4 to 4 m² area), cartridges (0.9 to 15 m² area), pleated washable cartridges, and discs.
  • Large filter areas extend operation time between maintenance.
  • Pre-coat tanks facilitate organic purification by allowing active carbon powder to obstruct the filter chamber, enabling clean and easy operations, self-priming, and direct addition of products from the pump.

Pumps

Two main pump types are used:

  • Magnetic Drive Pumps: Provide leak-free operation due to their operating principle, made from thermoplastic materials inert to most chemicals, compliant with CE directives ensuring quality and safety.
  • Mechanical Seal Pumps: Also available as an option.

Technical Specifications Table Summary

The document includes detailed tables listing MIX series models with parameters such as:

  • Plate dimensions and number (e.g., Ø 130 mm x 35 plates).
  • Cartridge sizes and quantities.
  • Filter area in square meters.
  • OILSORB volume in liters.
  • Pump models and power ratings (kW).
  • Maximum pump flow rates (m³/h).
  • Overall dimensions of standard versions (mm).

These specifications allow selection of appropriate filter units based on filtration area, flow rate, and physical size requirements.

Construction and Materials

  • Extensive use of polypropylene ensures chemical resistance and mechanical durability.
  • C-PVC lids provide secure sealing to prevent leaks.
  • Thermoplastic materials used in pumps contribute to chemical inertness.

Operational Benefits and Recommendations

  • Magnetic drive pumps are recommended for leak-free, reliable operation.
  • Pre-coat tanks simplify active carbon treatment and improve filtration efficiency.
  • Interchangeable filter media provide flexibility to adapt filtration to specific galvanic bath requirements.
  • Compliance with CE directives ensures safety and quality standards.

Contact and Manufacturer Information

La Fonte Srl
P.le Cocchi, 6 - 21040 Vedano Olona (VA), Italy
Tel: +39 0332 402168
Fax: +39 0332 402169
Website: www.lafonte.eu
Email: [email protected]

Disclaimer

La Fonte reserves the right to modify product specifications without prior notice as part of its continuous improvement policy.

See more

Catalog excerpts

MIX-1

Suction valve Discharge valve By-pass between pump/filter Active carbon treatment system valves Pressure gauge Valve between pump and filter Pre coat system Wheels Safe security system Splashproof Ring Splashproof Ring with interlock sensor OTHER PRODUCTION • • • • • Magnetic drive pumps Vertical pumps Cartridges and discs filter pumps Active carbon columns Precious metals recovery (by resin and electrolytic system) • Demineralizers • Oil scream It is the policy of la fonte always to improve its products, we reserve the right to alter specifications at any time without prior notice. P.le Cocchi, 6 - 21040 Vedano Olona (VA) Italy Tel. +39 0332 402168 - Fax +39 0332 402169 www.lafont

 Open the catalog to page 1
MIX-2

MULTIPROCESS FILTRATION AND PURIFICATION SYSTEM FILTER CHAMBER PRE-COAT TANK (DOSAGE) Extensive use of polypropylene provides an excellent resistance and mechanical strength, C-PVC lid assures the perfect closing and sealing of the filter. Many different sizes and the possibilty to use interchangeable filter paper and cartridges guarantee an excellent filtration in all circumstances. The large filter area (filter paper 0,4 ÷ 4 m2 - filter cartridges 0,9 ÷15 m 2 ) increases the operation time of the filter pump. The great versatility of the filter unit offers to the operator the possibility to...

 Open the catalog to page 2
MIX-3

PRE-COAT TANK (DOSAGE) The great versatility of the filter unit offers to the operator the possibility to choose between different kinds of filtration or purification with the same unit : • Process filter paper can be replaced by cartridges by simply changing the filter pack situated inside the filter. • The different kinds of filtration and purification (paper, meraklon cartridges washable pleated cartridges ) permit to choose the appropiate system for every galvanic bath filtration. Galvanic bath organic purification happens when the filter chamber is obstructed with active carbon powder. Pre-coat...

 Open the catalog to page 3
MIX-4

• a : Suction valve • m : Discharge valve • b : By-pass between pump/filter • c : Active carbon treatment system valves • g : Pressure gauge • v : Valve between pump and filter • t : Pre coat system • w : Wheels • s : Safe security system • r : Splashproof Ring • i : Splashproof Ring with interlock sensor • Magnetic drive pumps • Vertical pumps • Cartridges and discs filter pumps • Active carbon columns • Precious metals recovery (by resin and electrolytic system) • Demineralizers • Oil scream It is the policy of la fonte always to improve its products, we reserve the right to alter specifications...

 Open the catalog to page 4

All La Fonte catalogs and technical brochures

  1. EVT30

    2  Pages

  2. evm 8

    1  Page

  3. evt 25

    1  Page

  4. evt 12

    1  Page

  5. EVT4

    2  Pages

  6. DEPUR

    2  Pages

  7. BX15 - BX26

    2  Pages

  8. MCB - BX05

    2  Pages

  9. O3

    2  Pages

  10. evt 7

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.