1. Catalogs
  2. Kytola Instruments Oy
  3. KYTOLA OIL LUBRICATION FLOW MONITORING SOLUTIONS
video corpo

KYTOLA OIL LUBRICATION FLOW MONITORING SOLUTIONS
1 /16Pages

KYTOLA OIL LUBRICATION FLOW MONITORING SOLUTIONS

KYTOLA OIL LUBRICATION FLOW MONITORING SOLUTIONS
1 /16Pages

Catalog excerpts

KYTOLA OIL LUBRICATION FLOW MONITORING SOLUTIONS-1

KYTOLA OIL LUBRICATION FLOW MONITORING SOLUTIONS OVAL D2 MEASURING STATION up to 64 measuring channels 100% CORRECT FLOW RATE OVAL GEAR FLOW METERS single or multi-channel blocks STAINLESS STEEL OVAL FLOW INSTALLATION PANEL with or without inlet manifold

 Open the catalog to page 1
KYTOLA OIL LUBRICATION FLOW MONITORING SOLUTIONS-2

KYTOLA OIL LUBRICATION FLOW MONITORING SOLUTIONS MONITORING SOLUTION 1.SR OVAL GEAR FLOW METERS • Single or multi-channel models • Viscosity and temperature independent • Secured lubrication in all situations TOUCHSCREEN DISPLAY • Single or multi-channel models • Flow rate, totalizer and batching • Modbus RTU/Modbus TCP (Ethernet) MEASURING STATION • Flow-rate and multiple flow alarms STAINLESS STEEL • With or without plexiglass door • Mounted on a hood wall or floor stand

 Open the catalog to page 2
KYTOLA OIL LUBRICATION FLOW MONITORING SOLUTIONS-3

KYTOLA OIL LUBRICATION FLOW MONITORING SOLUTIONS THE COMPLETE OIL LUBRICATION FLOW MONITORING SOLUTION VARIABLE AREA OIL FLOW METERS FLOW ALARM MONITORING SYSTEMS OILCOL OIL COLOUR ANALYZERS KVM SUITE CONTROL ROOM SOFTWARE OVAL FLOW PANEL STAINLESS STEEL With or without plexiglass door Mounted on wall or stand-alone Oil supply manifold VARIABLE AREA MEASUREMENT FLOW ALARM MONITORING CONTROL ROOM SOFTWARE Single or multi-tube models Relative scales 20-100% or direct reading scale in required flow unit Low flow alarms 1-48 / 1-30 low flow alarm sensors Individual flow alarms/group alarm Modbus...

 Open the catalog to page 3
KYTOLA OIL LUBRICATION FLOW MONITORING SOLUTIONS-4

FLOW MONITORING SOLUTIONS It is estimated that 40-60% of bearing failures are caused by insufficient lubrication and lubricant contamination. Kytola helps you keep your processes up and running. Save time and money with Kytola oil flow monitoring solutions.

 Open the catalog to page 4
KYTOLA OIL LUBRICATION FLOW MONITORING SOLUTIONS-5

• Lubrication oil flow monitoring • Industrial flow monitoring • Process control • Pulp & Paper mills • Steel mills SECURED, OPTIMIZED AND RELIABLE OPERATION AT ALL TIMES, Avoiding one bearing failure can reimburse the cost of a Kytola lubrication monitoring system

 Open the catalog to page 5
KYTOLA OIL LUBRICATION FLOW MONITORING SOLUTIONS-6

KYTOLA SR OVAL GEAR FLOW METERS Kytola SR Oval gear flow meters measure oil flow rates with 100% reliability. The SR meter is a true positive displacement meter that always shows the correct flow rate on the whole measurement range, regardless of oil temperature and viscosity changes. The SR Oval gear flow meters have a by-pass valve that enables service on the run without need for downtime. They are superior in continuously lubricating the bearing, even if gears jam. FEATURES Several flow ranges from 0.1 - 1 L/min up to 200 L/min Multi-channel models for flow ranges of up to 6 L/min Viscosity...

 Open the catalog to page 6
KYTOLA OIL LUBRICATION FLOW MONITORING SOLUTIONS-7

KLD SMART TOUCH SCREEN DISPLAY The Kytola KLD Smart touchscreen display is designed to monitor and display flow rates and flow alarms measured by Kytola SR oval gear meters or other flow meters with pulse outputs. KLD Smart is conveniently operated using a touchscreen, which enables easy monitoring of flow rates and alarms, and management of settings. FEATURES 1 or 8 channel models Flow measurement Totalizer counter and batching Pulse or mA input Alarm relay Multiple flow units Multiple flow alarm levels Visible indication of alarm type 4-20 mA output Modbus RTU or Modbus TCP (Ethernet) communication...

 Open the catalog to page 7
KYTOLA OIL LUBRICATION FLOW MONITORING SOLUTIONS-8

OVAL D2 MEASURING STATION Kytola Oval D2 Measuring station is designed to monitor oil flow rates measured by SR oval gear flow meters in circulation lubrication systems. The Oval D2 measuring station operates as an independent station and it can be connected to Kytola KVM Suite monitoring software or to customer’s PLC or DCS via Modbus RTU protocol. FEATURES 16, 32, 48 or 64 measuring channels In excess of 100 measuring stations and thousands of measuring points in one serial communication line. Modbus RTU (RS-485 or RS-422) communication USB port for local configuration Display for flow rate,...

 Open the catalog to page 8
KYTOLA OIL LUBRICATION FLOW MONITORING SOLUTIONS-9

PANELS The Oval Flow panels with Oval D2 measuring stations and Kytola SR oval gear flow meters are ideal for oil flow monitoring in large processes where multiple, or even thousands, of lubrication points are used. The panel has a sturdy stainless steel construction, especially designed to withstand the harsh conditions in process industry. FEATURES Stainless steel With or without plexiglass door Mounting on a hood wall or floor mounting stand OIL SUPPLY MANIFOLD FEATURES Stainless steel Connections, shut-off valve, flushing etc. accordhing to customer's requirements

 Open the catalog to page 9
KYTOLA OIL LUBRICATION FLOW MONITORING SOLUTIONS-10

VARIABLEA AREA FLOW METERS Kytola variable area flow meters are cost-efficient flow meters made to withstand harsh industrial conditions. The flow meters provide a visual local flow indication and can be provided with flow alarm sensors. The flow meters come with relative scales 20-100% or direct reading scales in required flow unit. FEATURES Single or multi-channel models with up to 7 flow tubes With or without flow adjustment valve No electric power needed Quick-change tube (selected models) Flow alarm-ready Easy to read even with dark oils Sturdy construction with impact resistant flow tubes...

 Open the catalog to page 10
KYTOLA OIL LUBRICATION FLOW MONITORING SOLUTIONS-11

The Kytola Alarm I/O is a substation which is designed to transmit individual low flow alarms from Kytola variable area oil flow meters to control room. FEATURES For Kytola industrial variable area oil flow meter models VExA, KA and TLA For 1-48 low flow alarm sensors In excess of 100 substations and thousands of measuring points in one serial line Communication with upper level systems Modbus RTU protocol GROUP ALARM AMPLIFIER The Kytola NK alarm amplifier has a common relay output, which is activated and transmits an alarm signal to control room if one or more Kytola variable area flow meters...

 Open the catalog to page 11
KYTOLA OIL LUBRICATION FLOW MONITORING SOLUTIONS-12

OILCOLOIL COLOUR ANALYZER Kytola Oilcol Oil colour analyzer is an online instrument based on visible light absorbance (transmittance) to indicate the ASTM D1500 color value of oil. As the measurement is performed online, the response is continuous and fast, which can be crucial in order to detect sudden changes in oil quality and further to be able to react before any failures of the oil using equipment occur. Timeconsuming and expensive sampling and laboratory analyses are also avoided. FEATURES Online oil colour analyzer ASTM D1500 scale from 0.5 to 8.0 Accuracy ±0.3 (as the ASTM scale step...

 Open the catalog to page 12

All Kytola Instruments Oy catalogs and technical brochures

  1. PRODUCT CATALOG

    24  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.