= Wheels = Min/max temperature alarm = Graphic temperature recorder = Lock= Open door alarm= Broken probe alarm = Power failure alarm = Temperature programmer for thermal cycling RedLine IntroductionՕ AC AUTOCYCLE series legend digital fan-assisted electronic sterilizersΕ WS series natural guided convection laboratory ovens/sterilizers AC AUTOCYCLE ծ series digital fan-assisted electronic sterilizers TO THERMOSTATIC OVEN ծ series digital fan-assisted thermostatic electronic ovens KW.86/AV series dryer-desiccator cabinetՕ KW.86 series cabinet for sterile storage > KW APPARECCHI SCIENTIFICI
Open the catalog to page 2Ovens are basic instruments in any biological and industrial laboratory. They allow a T range between ambient T and 250-300 C , while incubators can reach a max T of around +70аC. Thermostatting. In the ovens , thermostatting can be obtained with different methods of air circulation: natural convection, forced and guided circulation. WS series ovens are with guided circulation, AC, TO, KWAV models are with forced circulation. Analyses at temperatures between ambient T and 300C are carried out in biotechnological research, in the food, pharmaceutical and cosmetic industry, or in all fields that...
Open the catalog to page 3T data recording can be conducted in combination with the electronic video graphic recorder (with the possibility to print the cycle) and RS8-RS communication interface. T stability and uniformity. Thermal stability is obtained with PID control (solid state relay); TO and AC series use the and with l ow thermal power density heating devices and with thermal power regulation by means of SSR AC series standard version is equipped with a programmer, in which the operator can programme and memorize multiple sterilization cycles , through the Economy Switch , in order to obtain three different heating...
Open the catalog to page 4Safety standards adopted are of the highest level and are meant for both product and operator. All RedLine standard models are equipped with an overtemperature device, with probe and regulation independent from the adopted control system , with visual indication panel, in conformity with DIN 12280 standards, class 3.1. Upon request, a dual safety system (for TO and AC series) is also available: an additional digital electronic safety system, that intervenes on the set T, while continuing to adjust it when the alarm is going off. Documentation attached to each oven can be provided upon request...
Open the catalog to page 5Reliability and lifespan. Internal chamber in AISI 304 stainless steel (or AISI 316), for all series, glossy barium construction and same for shelves , in perforated sheet steel, or stainless steel wire. For maximum resistance to corrosion. Internal chamber with rounded External cabinet is in painted sheet steel. edges for easy cleaning and maximum hygiene. ( WS ), or brushed AISI 304 stainless steel ( TO,AC,KW _ AV ); key lock handle for maximum operating security. Low energy consumption, with excellent insulation with natural mineral fibres and/or equivalent and with PID regulation and Economy...
Open the catalog to page 6gasket, in silicone rubber for high T, for maximum security against thermal dissipation from the door and minimum energy consumption Insulation in fibreglass, for maximum thermal protection and minimum energy consumptionAdvanced construction technology structure, in brushed AISI 304 stainless stee 1 8 Economy Switch , in order to obtain three different heating levels, according to the desired temperature control value (set point) for maximum stability of the controlled parameter and minimum energy consumption Supplemental probe for T, RTD Pt100, (optional) l and with internal chamber in AISI...
Open the catalog to page 8Model Externaldimensions (WxDxH) Internaldimensions (WxDxH) Capacity ShelvesN. Range ofadjustment % precisionon set value Power Weight WS 9WS 18 cm. 50x33x30 hcm. 53x35x35 h cm. 28x19x18 hcm. 31x26x23 h 10 l. 19 l. 22 (*) +200C(*) +200аC 2%ѱ 2%(*) Watt. 200 Watt. 400 Kg. 15 Kg. 22 + 5C above ambient T - Power:: 220/50/1 Volt > Model Externaldimensions (WxDxH) Internaldimensions (WxDxH) Capacity Shelves Range ofadjustment Power Weight WS 30WS 60WS 100 WS 140 WS 200 cm. 65x52x52 hcm. 90x52x52 h cm. 71x68x86 hcm. 71x68x104 h cm. 71x68x136 h cm. 31x32x34 hcm. 56x32x34 h cm. 53x46x42 h cm. 53x46x60...
Open the catalog to page 10W107 AC with potentiometric strip-chart recorder >
Open the catalog to page 11W0 AC - W06 AC - W07 AC - W08 AC SERIESThis sterilizer is recommended for all laboratories dealing with devices and products sterilized with hot air: hospitals, analysis laboratories, food and pharmaceutical industries, research centres, etc. STRUCTURE: HEATING: Internal chamber and shelves in glossy AISI 0 stainless steel, external cabinet in brushed AISI 0 stainless steel sheet. Therefore, high mechanical characteristics, good resistance to corrosion and extremely easy cleaning. Each appliance is equipped with racks to position AISI 0 perforated stainless steel shelves (therefore height-adjustable)....
Open the catalog to page 13W0 TO - W06 TO - W07 TO - W08 TO SERIESThis thermostatic oven is particularly recommended for heating and drying tests, thermal treatments and tests of samples ofvarious dimensions. STRUCTURE: HEATING: Internal chamber and shelves in glossy AISI 0 stainless steel, external cabinet in brushed AISI 0 stainless steel sheet metal. Therefore high mechanical characteristics, good resistance to corrosion and extremely easy cleaning. Each appliance is equipped with racks to position AISI 0 perforated stainless steel shelves (therefore height- adjustable). Internal architecture suitable for creation of...
Open the catalog to page 14KW.86/AV > seriesDryer desiccator cabinet KW.86/AV KW.86 KW.86 > seriesSterile storage cabinet 240 size="-2">
Open the catalog to page 15Model Externaldimensions (WxDxH) Internaldimensions (WxDxH) Capacity Shelves Power supply Power(installed) Weight KW.86/AV cm. 110x78x200 h cm. 95x60x150 h 855 l. n.4 V220/Hz. 50 Watt 1250 Kg. 190 T from +5հC above ambient T to +130C and beyond > Model Externaldimensions (WxDxH) Internaldimensions (WxDxH) Capacity Shelves Total supporting surface(bottom included) Power supply Power(installed) Weight KW.86 cm. 105x82x200 h cm. 95x68x185 h 1195 l. n.6 m 4,5 > 2 V220/Hz. 50 Watt 150 Kg. 175 > KW APPARECCHI SCIENTIFICI
Open the catalog to page 166 Pages