Overview: This document outlines the technical specifications and operational guidelines for KW APPARECCHI SCIENTIFICI's AC series sterilizers and TO series ovens, including contact information for company departments.
AC Series Sterilizers: These sterilizers use forced air convection, with a temperature range from +5°C above ambient to +300°C, maintaining stability within ±1°C. They come in various sizes and capacities, featuring potentiometric strip-chart recorders and optional double doors for sterile area separation.
TO Series Ovens: Operating similarly to the AC series, these ovens also use forced air convection and reach up to +300°C. They are designed for heating, drying tests, thermal treatments, and sample testing, with electronic digital PID regulation for precise temperature control.
Structure and Materials: Both series are made with glossy AISI stainless steel for internal chambers and brushed AISI stainless steel for external cabinets, offering mechanical strength, corrosion resistance, and easy cleaning. Centrifugal blowers ensure optimal air flow and temperature uniformity.
Thermoregulation and Controls: A PID digital electronic microprocessor regulates temperature, ensuring stability without overshoot or undershoot. Safety features include an overtemperature protection thermostat and operational alarms.
Heating and Cooling: Heating is provided by stainless steel tubular elements with low thermal density, and an economy switch allows for different heating levels. Natural cooling is achieved with a sterile filter to prevent contamination.
Accessories and Options: Accessories include adjustable valves, additional shelves, digital recorders, and probes for external connections. The equipment supports IQ and OQ qualifications and ISO calibration certification services.
Applications: The AC series is recommended for use in hospitals, analysis labs, food and pharmaceutical industries, and research centers. The TO series is suitable for heating and drying tests and thermal treatments.
See more

Catalog excerpts

RedLine - AC series-1

AC series electronic digital fan-assisted sterilizers TO series electronic thermostatic digital fanassisted ovens

 Open the catalog to page 1
RedLine - AC series-2

Contact us: Managing director: [email protected] Production and technician office: [email protected] Sales management: [email protected] Tenders and export office : [email protected] Export support: [email protected] Service and support: [email protected] [email protected] Logistics and shipments: [email protected] Administration office: [email protected]

 Open the catalog to page 2
RedLine - AC series-3

SurrtiHiu the rl ^sfc'irw .j,-1 cif^ji.-H'if - rjiifi fvrla r^uaJifu' Jr. prrHmfanml.iiitS? srxrjrriJJ Jlimmli iJifMzu iL-Jta <Jmi^iJir fl Sifhuiirrfl Otitow /* QrMirli ci^inifl: I'ftijfrfMriiiHV, jii'iiiiiir/iiur1. I'l'JNf.'ii-i, i■ —1'~ri■ rir■ i Jf iiyyrim" I"JJ i Beirut Hid f rr\r/j"i'r uiMrsHiirr |>LT r^j tiii'frtttori rii Titerca.fiinuafir. osptltalic iirifujilrir.

 Open the catalog to page 3
RedLine - AC series-4

AC series electronic digital fan-assisted sterilizers W107 AC with potentiometric strip-chart recorder TO series electronic thermostatic digital fan-assisted ovens W104 TO open

 Open the catalog to page 4
RedLine - AC series-5

AC AUTOCYCLE ® series fan-assisted digital electronic sterilizers External dimensions (WxDxH) Internal dimensions (WxDxH) Nominal power Empty weight Forced air convection operation Working range: from +5°C above ambient T to +300°C MAXIMUM TEMPERATURE +300°C T stability: ≤±1°C compared to all set point values. Temperatura Temp. Example of sterilizing cycle with hot air Esempio di ciclo di sterilizzazione ad aria calda (programmato con AUTOCYCLE®) (programmed with AUTOCYCLE®) SetSet point (sterilization T) point (T di sterilizzazione) For all AC models, KW offers D/version, or with double door,...

 Open the catalog to page 5
RedLine - AC series-6

AC AUTOCYCLE ® series fan-assisted digital electronic sterilizers W104 AC - W106 AC - W107 AC - W108 AC SERIES This sterilizer is recommended for all laboratories dealing with devices and products sterilized with hot air: hospitals, analysis laboratories, food and pharmaceutical industries, research centres, etc. STRUCTURE: Internal chamber and shelves in glossy AISI 304 stainless steel, external cabinet in brushed AISI 304 stainless steel sheet. Therefore, high mechanical characteristics, good resistance to corrosion and extremely easy cleaning. Each appliance is equipped with racks to position...

 Open the catalog to page 6
RedLine - AC series-7

TO THERMOSTATIC OVEN series electronic thermostatic digital fan-assisted ovens W104 TO - W106 TO - W107 TO - W108 TO SERIES This thermostatic oven is particularly recommended for heating and drying tests, thermal treatments and tests of samples of various dimensions. STRUCTURE: Internal chamber and shelves in glossy AISI 304 stainless steel, external cabinet in brushed AISI 304 stainless steel sheet metal. Therefore high mechanical characteristics, good resistance to corrosion and extremely easy cleaning. Each appliance is equipped with racks to position AISI 304 perforated stainless steel shelves...

 Open the catalog to page 7
RedLine - AC series-8

Contact us: Managing director: [email protected] Production and technician office: [email protected] Sales management: [email protected] Tenders and export office : [email protected] Export support: [email protected] Service and support: [email protected] [email protected] Logistics and shipments: [email protected] Administration office: [email protected] = Min/max temperature alarm = Power failure alarm = Broken probe alarm = Open door alarm = Temperature programmer for thermal cycling = Graphic temperature recorder • RedLine Introduction • AC AUTOCYCLE ® series legend digital fan-assisted...

 Open the catalog to page 8

Archived catalogs

  1. GreenLine

    40  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.