KFCE series horizontal freezers at -20 °C -30 °C Elite line
Open the catalog to page 1KFCE series horizontal freezers at -20 °C -30 °C Elite line
Open the catalog to page 2KFCE series horizontal freezers at -20 °C -30 °C Elite line KW offers this new series, featured by a wide range of volumes and a well-type structure characterized by an exceptional 100-mm. insulation thickness. This allows long preservation times in case of blackout. The fully sealed execution of the refrigerating circuit and the use of airtight compressors make these freezers a very silent and reliable option, even in critical environmental conditions. The materials and the fluids being used are all environmentally friendly, and particular attention is paid to problems dealing with the...
Open the catalog to page 3KFCE series horizontal freezers at -20 °C -30 °C Elite line KW distributes the KFCE line with two possible control systems, known by the initials SLC (Silver Line Control) and NIA (New Ice Age). The new control GLC (Golden Line Control) will take the place of SLC (see GLC release) Keyboard and display 4–key keyboard with menu structure and LED display, 2+1/2 digits with automatic digital point (between -19.9 °C and +19.9 °C), marked; perfectly visible with natural or artificial light from any angle. • SLC (Silver Line Control) system Electronic digital thermoregulator specific for...
Open the catalog to page 4KFCE series horizontal freezers at -20 °C -30 °C Elite line Visual alarms: SENSOR ALARMS In case of temperature alarm breakdown or failure. TEMPERATURE ALARM If, for any reason, the temperature starts increasing or decreasing until it falls outside the allowed range (configured with respect to the defined set point), the internal timer is activated (configurable alarm delay, 30 minutes by default but the value can be modified upon customer request); after this period the TEMPERATURE ALARM activates both visual and sound (BUZZER) alerts, and at the same time activates the remote alarm...
Open the catalog to page 5= min./max temperature alarm Contacts: Managing Director: management@kwkw.it Technical Production Manager: technician@kwkw.it Sales Manager: sales@kwkw.it Tender Commercial Office: commerciale@kwkw.it International Sales Manager: expdpt@kwkw.it Technical Support & Spare Parts: assistenza@kwkw.it Service line: service@kwkw.it Delivery Office: delivery@kwkw.it Administration: administration@kwkw.it = DATA LOGGER function = energy failure alarm = Alarm broken down probe = Open door alarm = Disaster Ricovery / Safety Control = Temperature recorder KW Apparecchi Scientici, taking into...
Open the catalog to page 6All KW catalogs and technical brochures
-
WPLR series
6 Pages
-
WRC series
3 Pages
-
SLC series
6 Pages
-
Catalog bloodline
15 Pages
-
BloodLine
8 Pages
-
model WPFD - WSCFD
10 Pages
-
KFT series
4 Pages
-
AC series / TO series
8 Pages
-
Model BBR 400CX 2D
4 Pages
-
Containers
4 Pages
-
BlueLine - IFM series
6 Pages
-
Climate Chamber series
6 Pages
-
KW.86 series
4 Pages
-
Incubator CO2 series
4 Pages
-
BlueLine
10 Pages
-
HS series
18 Pages
-
K.130 A/C series
6 Pages
-
GreenLine KW series
4 Pages
-
WS series
4 Pages
-
GreenLine WI series
4 Pages
-
Cold room series
10 Pages
-
RedLine - AC series
8 Pages
-
ServiceLine
32 Pages
-
BluLine: Low Temperature
176 Pages
Archived catalogs
-
GreenLine
40 Pages