Overview: This document outlines the specifications and features of the Green ICE series vertical freezers, designed for biological and pharmaceutical storage at temperatures between -20°C and -40°C. It includes models like the Power Plus KBPF-PP and K Freezelab Super_S KFS_NIA.
Specifications: The freezers are available in -40°C and -30°C configurations, featuring advanced refrigeration technology with internal ventilation for temperature uniformity and energy efficiency. They are constructed from pre-enamelled steel and AISI 304 stainless steel, with high-density polyurethane insulation.
Alarm and Monitoring System: Equipped with a comprehensive alarm system, the freezers alert users to high/low temperatures, door openings, and sensor failures. The system logs critical data and is supported by a backup battery for power failures.
Control and Interface: The NEW ICE AGE COMPACT KW CONTROL system provides precise thermoregulation and user-friendly operation, featuring a backlit alphanumeric LCD display for real-time updates and alarm notifications. It supports data logging and PC interfacing via RS 485 and USB ports.
Structural Features: The freezers have a single-body structure with reversible doors, magnetic gaskets, and automatic closing mechanisms. They include adjustable shelves and a pressure-compensation valve for easy door operation, ensuring minimal temperature fluctuations.
Energy Efficiency and Safety: Designed for low energy consumption, the freezers feature NIGHT & DAY mode for energy savings and safety controls to maintain temperature stability during sensor failures.
Additional Features: The InfoTest function allows functional tests on the equipment, and the Service Check feature aids in diagnosing issues. The document highlights the freezers' reliability and adaptability to various conditions.
Alarm Systems: The equipment's alarm system monitors conditions like high/low temperatures, blackouts, and sensor failures, with visual and sound alerts. Detailed data for each alarm event is recorded.
Testing Procedures: Procedures for testing alarms and system components, including buzzer sound and backup systems, are described to ensure functionality without activating the buzzer during registration.
Accessories: Available accessories enhance functionality, including wheel kits, insulated doors, additional shelves, monitoring kits, data loggers, and remote management systems, supporting Installation Qualification (IQ) and Operational Qualification (OQ).
Technical Support and Contact Information: Contact details for KW Apparecchi Scientifici's departments are provided, emphasizing quality commitment and potential product modifications without notice.
Certifications: The company holds certifications like ISO 9001:2008, ISO 13485:2003, OHSAS 18001:2007, and ISO 14001:2004, ensuring compliance with international quality and safety standards.
See more

Catalog excerpts

BlueLine-1

BlueLine K Biological & Pharmacy Freezer series Power Plus KBPF-PP vertical freezers at -40 °C K Freezelab Super_S KFS_NIA series vertical freezers at -30 °C

 Open the catalog to page 1
BlueLine-2

K Biological & Pharmacy Freezer series Power Plus KBPF-PP vertical freezers at -40 °C K Freezelab Super_S KFS_NIA series vertical freezers at -30 °C Green ICE

 Open the catalog to page 2
BlueLine-3

The K FREEZELAB SUPER S e KBPF-PP lines create a new standard for lower-temperature refrigeration (-20 °C up to -40 °C) for laboratories: - highly advanced refrigeration technology with internal ventilation and without defrost problems; low consumption; high T uniformity - 90-mm. insulation with heated gaskets - NIA (New Ice Age Control) electronic digital instruments for maximum safety: essential for demanding users or when the laboratory has a quality certification. The LCD display informs about the system's operation status and temperature. • Backlit alphanumeric LCD display Easy to read,...

 Open the catalog to page 3
BlueLine-4

vertical freezers at -40 °C vertical freezers at -30 °C For the previous conditions, the buzzer is activated in addition to the visual display. It can be muted by pressing the ENTER key. − blackout alarm (or power or network failure) − sensor failure (regulation sensor, evaporator sensor, condenser sensor) − functional failures (defrost timeout, dirty condenser, high condensation temperature, low evaporation temperature, compressor time) For each door open alarm, the controller records the following data: − critical number of door openings/total number of openings/total opening time in min. −...

 Open the catalog to page 4
BlueLine-5

door hinge compensation valve REFRIGERATION: Ventilated refrigeration: this is because of the large volume in the work chamber, but there are minimal T differences in the internal space = max. uniformity of the temperature parameter. The refrigeration system is fully sealed; it uses a circuit with innovative components (copper coils connected to the external walls of the internal chamber) and fluids to obtain, together, maximum cooling reliability and performance; the KBPF600X-PP (-40°C) version has a airtight 1.7 HP compressor with high refrigerating capacity and low noise (value Leq dB (A)...

 Open the catalog to page 5
BlueLine-6

vertical freezers at -40 °C vertical freezers at -30 °C The InfoTest function allows the user to replicate the same test types performed at the factory. InfoTest executes functional tests for the biological freezer, with report printing if necessary, without engaging external devices. This tool is configured in just a few seconds by means of the fast selection of one of the resident programs. Green ICE Special functions Info Test Allows the execution of the functional test, with its potent diagnostic features, on the refrigeration equipment, either during the manufacturing stage or during technical...

 Open the catalog to page 6
BlueLine-7

vertical freezers at -40 °C vertical freezers at -30 °C Alarm with active buzzer and flashing lights: with activation of (remote) alarm relay • High/Low internal temperature alarm, providing a pre-alarm function that, for a time determined by KW, displays the abnormal condition but does not trigger the visual/sound alarm or the remote signalling, in case there is a spontaneous correction of the issue and not to create excessive alarms for the final user. • blackout alarm • critical door opening (door open for a period > max. time) • sensor failure (regulation sensor, evaporator sensor, condenser...

 Open the catalog to page 7
BlueLine-8

vertical freezers at -40 °C vertical freezers at -30 °C KEY TEST Pressing the down arrow key activates the automatic alarm test procedure • Buzzer sound • CO2 or LN2 backup system (with valve activation) • Remote alarm relay (visualises the voltage of the backup battery) • Battery • High temperature alarm • Low temperature alarm • Fixed wheel kit (for KFS-NIA) • 2 counter doors insulated by means of high-density (thickness of 20 mm.) (for KFS-NIA) • Additional internal grilled shelves in chromed steel • Removable (drilled) drawer in AISI 304 stainless steel, mounted on anti-rollover sliding rails...

 Open the catalog to page 8
BlueLine-9

vertical freezers at -40 °C vertical freezers at -30 °C Sofware ColdMaster Pi Is Setup Lingua Infer mazbni Porta Seifale Nome cella Eliminaceto KWAPPARECCHI SCIENTIFIC! • ColdMaster Software Rete Ethernet

 Open the catalog to page 9
BlueLine-10

= min./max temperature alarm Contacts: Managing Director: [email protected] Technical Production Manager: [email protected] Sales Manager: [email protected] Tender Commercial Office: [email protected] International Sales Manager: [email protected] Technical Support & Spare Parts: [email protected] Service line: [email protected] Delivery Office: [email protected] Administration: [email protected] = DATA LOGGER function = energy failure alarm = Alarm broken down probe = Open door alarm = Disaster Ricovery / Safety Control = Temperature recorder KW Apparecchi Scientici, taking into consideration...