Overview: The RDLO Axially Split Volute Casing Pump is designed for handling various types of water, including pure, raw, industrial, and seawater. It is suitable for applications in water works, irrigation, drainage pumping stations, power stations, industrial water supply, petrochemical industry, marine and offshore engineering, and seawater desalination.
Key Features:
  • High Operating Reliability: The pump features a double volute casing and a double-entry impeller, minimizing radial and axial forces on the bearings, ensuring a calculated operating life of at least 100,000 hours.
  • Low Maintenance Costs: Solid bearing brackets, a rigid shaft, and corrosion-resistant materials contribute to low vibrations and extended service life of components such as bearings, seals, and coupling.
  • Service-Friendly Design: The self-centering upper casing and pre-loaded rotor allow for easy assembly and maintenance, with accessible internal components.
  • Reliable Sealing: A solid casing split flange ensures effective sealing between the upper and lower casing halves.
Compliance: The pump complies with Directive 94/9/EC ATEX 100a, suitable for use in potentially explosive atmospheres (II 2G c T1-T5).
Materials: The pump is constructed from various materials, including grey cast iron, nodular cast iron, duplex cast steel, CrNi steel, bronze, and Cr steel, with options for other materials upon request.
Technical Data:
  • Pump Sizes: DN 350 – 700 (14 – 28 inches)
  • Flow Rate: Up to 10,000 m3/h (44,030 gpm)
  • Discharge Head: Up to 240 m (787 ft)
  • Operating Pressure: Up to 25 bar (363 psi)
  • Temperature: Up to 80°C (176°F), with options for up to 140°C (284°F) on request
See more

Catalog excerpts

RDLO-1

RDLO – Axially split Volute Casing Pump Applications: For handling pure, raw and industrial water as well as seawater in ■ Water works ■ Irrigation and drainage pumping stations ■ Power stations ■ Industrial water supply ■ General applications in the petrochemical industry ■ Marine and offshore engineering ■ Seawater desalination More information: www.ksb.com/products

 Open the catalog to page 1
RDLO-2

RDLO – Axially split Volute Casing Pump 1 High operating reliability The self-centring upper part of the casing and the preloaded rotor enable cover and rotor assembly without impeller (compensating the axial forces) the bearings any further adjustments. For maintenance, the cover‘s only experience a minimum load. The calculated hexagon head bolts are completely removed from the operating life L10 for all sizes is at least 100,000 hours. casing. The casing split flange can therefore be cleaned easily and thoroughly, and the inside of the pump is freely accessible. The combination of solid bearing...

 Open the catalog to page 2

All KSB catalogs and technical brochures

  1. RPH

    2  Pages

  2. HERA-BD

    2  Pages

  3. SISTO-10

    24  Pages

  4. BOA-CVE H

    2  Pages

  5. UPA

    104  Pages

  6. HPK-L

    2  Pages

  7. KWP

    2  Pages

  8. Etachrom L

    2  Pages

  9. Amarex N

    2  Pages

  10. Etaline-R

    2  Pages

  11. BOA-R

    16  Pages

  12. TRIODIS 150

    2  Pages

  13. Etabloc SYT

    2  Pages

  14. Amaclean

    12  Pages

  15. Amacan S

    2  Pages

  16. Amacan P

    2  Pages

  17. Amacan K

    2  Pages

  18. UGS

    12  Pages

  19. ACTELEC EZ SQ

    20  Pages

  20. ACTELEC SQ AUMA

    14  Pages

  21. PumpMeter

    12  Pages

  22. KSB Sonolyzer

    5  Pages

  23. Etachrom L

    40  Pages

  24. Etanorm/Etabloc

    70  Pages

  25. AKG-A/AKGS-A

    12  Pages

  26. Amamix

    2  Pages

  27. Amaprop

    2  Pages

  28. HQ

    2  Pages

  29. BOAX-CBV13

    3  Pages

  30. Magnochem

    2  Pages

  31. Secochem Ex

    2  Pages

  32. Hya-Solo D

    44  Pages

  33. HGB, HGC

    4  Pages

  34. GZ 9

    2  Pages

  35. Etaseco

    2  Pages

  36. SuPremE

    2  Pages

  37. Etanorm

    2  Pages

  38. Etaline

    2  Pages

  39. CTN / -H

    2  Pages

  40. CINCP / CINCN

    2  Pages

  41. CHTD

    2  Pages

  42. CHTC

    2  Pages

  43. Calio S

    2  Pages

  44. AMADS

    2  Pages

  45. YNK

    2  Pages

  46. RHR/RVR

    2  Pages

  47. RHM

    2  Pages

  48. HGC

    2  Pages

  49. RPHb

    2  Pages

  50. MegaCPK

    2  Pages

  51. RPH-V

    2  Pages

  52. Multitec

    2  Pages

  53. INVCP

    2  Pages

Archived catalogs

  1. Riotherm

    4  Pages

  2. PHZ

    15  Pages

  3. Ixo

    4  Pages

  4. UPA

    118  Pages

  5. MR 25 to 1600

    16  Pages

  6. Rio/Rio Z

    32  Pages

  7. Rio-Eco/Z

    24  Pages

  8. LSA-S

    4  Pages

  9. CTN

    4  Pages

  10. VTS

    4  Pages

  11. Trialine

    12  Pages

  12. Trialine Z

    12  Pages

  13. ZJSVA/ ZXSVA

    6  Pages

  14. BOA-RVK

    4  Pages

  15. MN

    4  Pages

  16. HGM

    4  Pages

  17. BOACHEM

    4  Pages

  18. HERA BD

    6  Pages

  19. BOA-H

    2  Pages

  20. BOA-CVE

    16  Pages

  21. Ama-Porter

    24  Pages

  22. Ama-Porter ICS

    16  Pages

  23. MAT-P

    4  Pages

  24. MA

    4  Pages

  25. Amaprop

    4  Pages

  26. Omega / Omega V

    56  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.