Ama-Drainer 80/100
20Pages

{{requestButtons}}

Catalog excerpts

Ama-Drainer 80/100 - 1

Submersible Waste Water Pump Type Series Booklet

Open the catalog to page 1
Ama-Drainer 80/100 - 2

Legal information/Copyright Type Series Booklet Ama-Drainer 80/100 All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed for any other purpose, nor otherwise transmitted, published or made available to a third party without the manufacturer's express written consent. Subject to technical modification without prior notice. © KSB SE & Co. KGaA, Frankenthal 12/09/2018

Open the catalog to page 2
Ama-Drainer 80/100 - 4

Building Services: Drainage Drainage Pumps / Waste Water Pumps Operating data Operating properties Building Services: Drainage Drainage Pumps / Waste Water Pumps Ama-Drainer 80/100 Main applications ■ Drainage ■ Disposal ■ Drainage systems ■ Lowering groundwater levels ■ Maintaining groundwater levels ■ Draining of pits, shafts, etc. ■ Building site drainage ■ Construction pit drainage ■ Emergency pump in the event of flooding Fluids handled Standard design ■ Slightly contaminated water ■ Solid particles with a particle size of up to 12 mm Variant B/BH ■ Water containing sand Design details...

Open the catalog to page 4
Ama-Drainer 80/100 - 5

Building Services: Drainage Drainage Pumps / Waste Water Pumps Shaft seal ■ Pump end: 1 mechanical seal ■ Drive end: 1 mechanical seal ■ Liquid reservoir between the seals for cooling and lubrication Impeller type ■ Open multi-vane impeller Bearings ■ Maintenance-free ■ Grease-packed rolling element bearings sealed for life Electrical connection Ama-Drainer (B/BH) 80 for DOL starting: ■ Ama-Drainer pump sets for 3~400 V are supplied ready to be plugged in as standard. The scope of supply includes a power cable, CEE plug, phase inverter, phase sequence indicator, equipment-on lamp, fault...

Open the catalog to page 5
Ama-Drainer 80/100 - 6

Building Services: Drainage Drainage Pumps / Waste Water Pumps Overview of product features / selection tables Table of fluids handled The table of fluids handled is a selection aid for different applications. It serves as guidance and is based on long-standing experience. The data are reference values and are not to be considered generally binding recommendations. They shall not be the basis for warranty claims. Please contact your nearest sales branch for in-depth advice. Table of fluids handled X = standard For improved fire protection in building services. Variant: power supply cables...

Open the catalog to page 6
Ama-Drainer 80/100 - 7

Building Services: Drainage Drainage Pumps / Waste Water Pumps Technical data Free passage Material variants Standard/B/BH Special connection elbow see pump accessories

Open the catalog to page 7
Ama-Drainer 80/100 - 8

Building Services: Drainage Drainage Pumps / Waste Water Pumps Characteristic curves Ama-Drainer 80/100; n = 2800 rpm, multi-vane impeller 0 28 Fig. 1: Free passage: Ama-Drainer 80/100 = 12 mm Performance tolerance to ISO 2548 Class C (water under standard conditions)

Open the catalog to page 8
Ama-Drainer 80/100 - 9

Building Services: Drainage Drainage Pumps / Waste Water Pumps

Open the catalog to page 9
Ama-Drainer 80/100 - 10

Building Services: Drainage Drainage Pumps / Waste Water Pumps Installation example of a dual-pump station 80/100 ND

Open the catalog to page 10
Ama-Drainer 80/100 - 11

Building Services: Drainage Drainage Pumps / Waste Water Pumps AccessoriesPump accessories

Open the catalog to page 11
Ama-Drainer 80/100 - 12

Building Services: Drainage Drainage Pumps / Waste Water Pumps Control units / switchgear Item Description Motor protection switchgear MSD Float switch Dimensions (H × W × D): E10 E12 100 × 170 × 112 mm LevelControl Basic 2 control unit for singlepump station Required in addition: 1 float switch or 4...20 mA sensor, optionally with master switch DOL starting, with manual-0-automatic selector switch, indicator lamps and control panel, high water alert, integrated alarm buzzer 85 dB(A), optional mains-independent alarm via rechargeable battery, operating hours counter / start-stop cycles per...

Open the catalog to page 12
Ama-Drainer 80/100 - 13

Building Services: Drainage Drainage Pumps / Waste Water Pumps Connection to the control station With the exception of MSD, each control unit / switchgear features a volt-free contact for transmitting the general fault message to the control station. Optional components are not EDI-compatible (configurable range). LevelControl Basic 2 control units Symbols key Symbol Optional Control unit feature Not a control unit feature Comparison of functions of single-pump stations and dual-pump stations Feature 400 V: 6-10 A 400 V: 13-18 A Functions Draining Filling via float switch(es) Stand-by pump:...

Open the catalog to page 13
Ama-Drainer 80/100 - 14

Building Services: Drainage Drainage Pumps / Waste Water Pumps

Open the catalog to page 14
Ama-Drainer 80/100 - 15

Building Services: Drainage Drainage Pumps / Waste Water Pumps Alarm switchgears for pumps without ATEX AS 0/AS 1/AS 2/AS 4/AS 5 Item Plastic housing, IP20, H × W × D = 140 × 80 × 57 [mm]. Use float switch, F1 leakage sensor (item E64), M1 alarm contactor or signal relay of control unit as contactor. Alarm switchgearAS 2 29128422 with circuit breaker, acoustic signal transmitter with 85 dB(A), green equipment-on lamp With circuit breaker, acoustic signal transmitter with 85 dB(A), green equipment-on lamp, volt-free contact for hook-up to a control station Plastic housing, IP20, H × W × D =...

Open the catalog to page 15
Ama-Drainer 80/100 - 16

Building Services: Drainage Drainage Pumps / Waste Water Pumps Control unit / switchgear accessories Overview of control units 4) Not suitable for LevelControl Basic 2.

Open the catalog to page 16
Ama-Drainer 80/100 - 17

Building Services: Drainage Drainage Pumps / Waste Water Pumps Exploded view and list of components 550.21 932.32 550.1 Fig. 2: Exploded view List of components Part No. Volute casing Casing insert Inlet ring Suction cover Pump foot Impeller Impeller hub cap Deep groove ball bearing Bearing cover Gasket Profile seal End connector CEE motor protection plug Terminal box cover Terminal clamp Float switch Plug-in sleeve Flat connector Coupling connector Pressure screw Motor housing Stator core pack

Open the catalog to page 17
Ama-Drainer 80/100 - 18

Building Services: Drainage Drainage Pumps / Waste Water Pumps

Open the catalog to page 18
Ama-Drainer 80/100 - 20

KSB SE & Co. KGaA Johann-Klein-StraGe 9 • 67227 Frankenthal (Germany) Tel. +49 6233 86-0 www.ksb.com

Open the catalog to page 20

All KSB catalogs and technical brochures

  1. RPH

    2 Pages

  2. Amamix

    2 Pages

  3. HERA-BD

    2 Pages

  4. SISTO-10

    24 Pages

  5. BOA-CVE H

    2 Pages

  6. UPA

    104 Pages

  7. HPK-L

    2 Pages

  8. KWP

    2 Pages

  9. Etachrom L

    2 Pages

  10. Amarex N

    2 Pages

  11. Etaline-R

    2 Pages

  12. BOA-R

    16 Pages

  13. TRIODIS 150

    2 Pages

  14. Etabloc SYT

    2 Pages

  15. Amaclean

    12 Pages

  16. Amacan S

    2 Pages

  17. Amacan P

    2 Pages

  18. Amacan K

    2 Pages

  19. UGS

    12 Pages

  20. ACTELEC EZ SQ

    20 Pages

  21. PumpMeter

    12 Pages

  22. Etachrom L

    40 Pages

  23. AKG-A/AKGS-A

    12 Pages

  24. Amamix

    2 Pages

  25. Amaprop

    2 Pages

  26. HQ

    2 Pages

  27. BOAX-CBV13

    3 Pages

  28. Magnochem

    2 Pages

  29. Secochem Ex

    2 Pages

  30. Hya-Solo D

    44 Pages

  31. HGB, HGC

    4 Pages

  32. GZ 9

    2 Pages

  33. Etaseco

    2 Pages

  34. Etanorm

    2 Pages

  35. Etaline

    2 Pages

  36. CTN / -H

    2 Pages

  37. CHTC

    2 Pages

  38. Calio S

    2 Pages

  39. AMADS

    2 Pages

  40. YNK

    2 Pages

  41. RHR/RVR

    2 Pages

  42. RHM

    2 Pages

  43. HGC

    2 Pages

  44. CHTD

    2 Pages

  45. RPHb

    2 Pages

  46. MegaCPK

    2 Pages

  47. RPH-V

    2 Pages

  48. RDLO

    2 Pages

  49. Multitec

    2 Pages

  50. INVCP

    2 Pages

  51. SuPremE

    2 Pages

Archived catalogs

  1. MR 25 to 1600

    16 Pages

  2. MN

    4 Pages

  3. MA

    4 Pages

  4. MAT-P

    4 Pages

  5. BOA-CVE

    16 Pages

  6. VTS

    4 Pages

  7. BOA-RVK

    4 Pages

  8. HERA BD

    6 Pages

  9. ZJSVA/ ZXSVA

    6 Pages

  10. BOACHEM

    4 Pages

  11. BOA-H

    2 Pages

  12. LSA-S

    4 Pages

  13. HGM

    4 Pages

  14. Trialine

    12 Pages

  15. Trialine Z

    12 Pages

  16. Rio-Eco/Z

    24 Pages

  17. Riotherm

    4 Pages

  18. Rio/Rio Z

    32 Pages

  19. PHZ

    15 Pages

  20. Ixo

    4 Pages

  21. CTN

    4 Pages

  22. UPA

    118 Pages

  23. Ama-Porter

    24 Pages

  24. Ama-Porter ICS

    16 Pages

  25. Amaprop

    4 Pages