Product catalog summary
Main Applications
  • Used in drainage and disposal systems.
  • Effective for lowering and maintaining groundwater levels.
  • Suitable for draining pits, shafts, and construction sites.
  • Functions as an emergency pump for flooding situations.
Fluids Handled
  • Capable of handling slightly contaminated water.
  • Can manage water with solid particles up to 12 mm.
  • Variant B/BH is designed for water containing sand.
Operating Data
  • Flow rate reaches up to 130 m³/h or 36 l/s.
  • Head capacity is up to 26 m.
  • Fluid temperature can be up to 50°C (standard), 40°C (variant B/BH), and 90°C for short durations.
  • Immersion depth is up to 7 m (standard) and 10 m (variant B/BH).
Design Details
  • Features a fully floodable submersible motor pump.
  • Close-coupled, single-stage design with a vertical discharge nozzle.
  • Materials are coated with anti-corrosive substances.
  • Motor winding complies with IEC 60038 standards.
  • Enclosure is rated at IP68.
Materials
  • Pump casing made of grey cast iron.
  • Impeller options include grey cast iron or Norihard white cast iron (variant BH).
  • Mechanical seal is made of tungsten carbide.
Product Benefits
  • Ready-to-connect for easy installation.
  • Reliable shaft sealing with SiC/SiC mechanical seal.
  • Maintenance-free due to grease-packed bearings.
  • Suitable for sand-containing water (variant B/BH).
Technical Data
  • Available in material variants: Standard, B, BH.
  • Power cable lengths are 10 m (standard) and 20 m (variant B/BH).
Characteristic Curves
  • Performance tolerance adheres to ISO 2548 Class C.
Dimensions
  • Offers various connection options and dimensions for installation.
Accessories
  • Includes check valves, gate valves, and installation accessories.
  • Control units and switchgear are available.
Overview: The document outlines the technical specifications and operational guidelines for the LevelControl Basic 2 control unit, which is designed for dual-pump stations in drainage and wastewater management systems. It details required components, optional features, and operational functions.
Specifications: The LevelControl Basic 2 is suitable for dual-pump stations and requires additional components such as a float switch or a 4-20 mA sensor. It features DOL starting, a manual-0-automatic selector switch, indicator lamps, a control panel, and a high water alert system. The unit includes an integrated alarm buzzer with an 85 dB(A) output and offers optional mains-independent alarm functionality via a rechargeable battery. It also provides voltage measurement, phase monitoring, and motor temperature warning with automatic reset/restart functions.
Dimensions: The control unit is available in two sizes: BC (400 × 281 × 135 mm) and BS (800 × 600 × 200 mm).
Optional Components: Optional components include a master switch for type BC, control cabinet heating for type BS, and various alarm switchgears. These components enhance the functionality and safety of the control unit.
Operational Functions: The LevelControl Basic 2 supports various operational functions such as draining, filling via float switches, pump changeover, peak load operation, and runtime limitation. It also features a 7-segment display for operation and fault indication, multicolour LEDs for pump status, and a volt-free contact for general fault messages.
Alarm and Monitoring: The unit includes alarm equipment with a piezo buzzer, digital input for high water alerts, and volt-free contacts for fault messages. It supports remote acknowledgment and has inputs for float switches and 4-20 mA analog inputs.
Accessories: The document lists various accessories such as float switches, leakage sensors, and rechargeable battery retrofit kits, which are compatible with the LevelControl Basic 2.
Exploded View and Components: An exploded view diagram and a list of components are provided for the Ama-Drainer 80/100, detailing parts such as the volute casing, impeller, mechanical seal, and motor housing.
Conclusion: The LevelControl Basic 2 is a comprehensive control unit for dual-pump stations, offering robust monitoring and control features essential for effective drainage and wastewater management.
See more

Catalog excerpts

Ama-Drainer 80/100-1

Submersible Waste Water Pump Type Series Booklet

 Open the catalog to page 1
Ama-Drainer 80/100-2

Legal information/Copyright Type Series Booklet Ama-Drainer 80/100 All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed for any other purpose, nor otherwise transmitted, published or made available to a third party without the manufacturer's express written consent. Subject to technical modification without prior notice. © KSB SE & Co. KGaA, Frankenthal 12/09/2018

 Open the catalog to page 2
Ama-Drainer 80/100-4

Building Services: Drainage Drainage Pumps / Waste Water Pumps Operating data Operating properties Building Services: Drainage Drainage Pumps / Waste Water Pumps Ama-Drainer 80/100 Main applications ■ Drainage ■ Disposal ■ Drainage systems ■ Lowering groundwater levels ■ Maintaining groundwater levels ■ Draining of pits, shafts, etc. ■ Building site drainage ■ Construction pit drainage ■ Emergency pump in the event of flooding Fluids handled Standard design ■ Slightly contaminated water ■ Solid particles with a particle size of up to 12 mm Variant B/BH ■ Water containing sand Design details Design ■...

 Open the catalog to page 4
Ama-Drainer 80/100-5

Building Services: Drainage Drainage Pumps / Waste Water Pumps Shaft seal ■ Pump end: 1 mechanical seal ■ Drive end: 1 mechanical seal ■ Liquid reservoir between the seals for cooling and lubrication Impeller type ■ Open multi-vane impeller Bearings ■ Maintenance-free ■ Grease-packed rolling element bearings sealed for life Electrical connection Ama-Drainer (B/BH) 80 for DOL starting: ■ Ama-Drainer pump sets for 3~400 V are supplied ready to be plugged in as standard. The scope of supply includes a power cable, CEE plug, phase inverter, phase sequence indicator, equipment-on lamp, fault indicator...

 Open the catalog to page 5
Ama-Drainer 80/100-6

Building Services: Drainage Drainage Pumps / Waste Water Pumps Overview of product features / selection tables Table of fluids handled The table of fluids handled is a selection aid for different applications. It serves as guidance and is based on long-standing experience. The data are reference values and are not to be considered generally binding recommendations. They shall not be the basis for warranty claims. Please contact your nearest sales branch for in-depth advice. Table of fluids handled X = standard For improved fire protection in building services. Variant: power supply cables free...

 Open the catalog to page 6
Ama-Drainer 80/100-7

Building Services: Drainage Drainage Pumps / Waste Water Pumps Technical data Free passage Material variants Standard/B/BH Special connection elbow see pump accessories

 Open the catalog to page 7
Ama-Drainer 80/100-8

Building Services: Drainage Drainage Pumps / Waste Water Pumps Characteristic curves Ama-Drainer 80/100; n = 2800 rpm, multi-vane impeller 0 28 Fig. 1: Free passage: Ama-Drainer 80/100 = 12 mm Performance tolerance to ISO 2548 Class C (water under standard conditions)

 Open the catalog to page 8
Ama-Drainer 80/100-9

Building Services: Drainage Drainage Pumps / Waste Water Pumps

 Open the catalog to page 9
Ama-Drainer 80/100-10

Building Services: Drainage Drainage Pumps / Waste Water Pumps Installation example of a dual-pump station 80/100 ND

 Open the catalog to page 10
Ama-Drainer 80/100-11

Building Services: Drainage Drainage Pumps / Waste Water Pumps AccessoriesPump accessories

 Open the catalog to page 11
Ama-Drainer 80/100-12

Building Services: Drainage Drainage Pumps / Waste Water Pumps Control units / switchgear Item Description Motor protection switchgear MSD Float switch Dimensions (H × W × D): E10 E12 100 × 170 × 112 mm LevelControl Basic 2 control unit for singlepump station Required in addition: 1 float switch or 4...20 mA sensor, optionally with master switch DOL starting, with manual-0-automatic selector switch, indicator lamps and control panel, high water alert, integrated alarm buzzer 85 dB(A), optional mains-independent alarm via rechargeable battery, operating hours counter / start-stop cycles per pump,...

 Open the catalog to page 12
Ama-Drainer 80/100-13

Building Services: Drainage Drainage Pumps / Waste Water Pumps Connection to the control station With the exception of MSD, each control unit / switchgear features a volt-free contact for transmitting the general fault message to the control station. Optional components are not EDI-compatible (configurable range). LevelControl Basic 2 control units Symbols key Symbol Optional Control unit feature Not a control unit feature Comparison of functions of single-pump stations and dual-pump stations Feature 400 V: 6-10 A 400 V: 13-18 A Functions Draining Filling via float switch(es) Stand-by pump: 1...

 Open the catalog to page 13
Ama-Drainer 80/100-14

Building Services: Drainage Drainage Pumps / Waste Water Pumps

 Open the catalog to page 14
Ama-Drainer 80/100-15

Building Services: Drainage Drainage Pumps / Waste Water Pumps Alarm switchgears for pumps without ATEX AS 0/AS 1/AS 2/AS 4/AS 5 Item Plastic housing, IP20, H × W × D = 140 × 80 × 57 [mm]. Use float switch, F1 leakage sensor (item E64), M1 alarm contactor or signal relay of control unit as contactor. Alarm switchgearAS 2 29128422 with circuit breaker, acoustic signal transmitter with 85 dB(A), green equipment-on lamp With circuit breaker, acoustic signal transmitter with 85 dB(A), green equipment-on lamp, volt-free contact for hook-up to a control station Plastic housing, IP20, H × W × D = 140...

 Open the catalog to page 15
Ama-Drainer 80/100-16

Building Services: Drainage Drainage Pumps / Waste Water Pumps Control unit / switchgear accessories Overview of control units 4) Not suitable for LevelControl Basic 2.

 Open the catalog to page 16
Ama-Drainer 80/100-17

Building Services: Drainage Drainage Pumps / Waste Water Pumps Exploded view and list of components 550.21 932.32 550.1 Fig. 2: Exploded view List of components Part No. Volute casing Casing insert Inlet ring Suction cover Pump foot Impeller Impeller hub cap Deep groove ball bearing Bearing cover Gasket Profile seal End connector CEE motor protection plug Terminal box cover Terminal clamp Float switch Plug-in sleeve Flat connector Coupling connector Pressure screw Motor housing Stator core pack

 Open the catalog to page 17
Ama-Drainer 80/100-18

Building Services: Drainage Drainage Pumps / Waste Water Pumps

 Open the catalog to page 18
Ama-Drainer 80/100-20

KSB SE & Co. KGaA Johann-Klein-StraGe 9 • 67227 Frankenthal (Germany) Tel. +49 6233 86-0 www.ksb.com

 Open the catalog to page 20

All KSB catalogs and technical brochures

  1. RPH

    2  Pages

  2. HERA-BD

    2  Pages

  3. SISTO-10

    24  Pages

  4. BOA-CVE H

    2  Pages

  5. UPA

    104  Pages

  6. HPK-L

    2  Pages

  7. KWP

    2  Pages

  8. Etachrom L

    2  Pages

  9. Amarex N

    2  Pages

  10. Etaline-R

    2  Pages

  11. BOA-R

    16  Pages

  12. TRIODIS 150

    2  Pages

  13. Etabloc SYT

    2  Pages

  14. Amaclean

    12  Pages

  15. Amacan S

    2  Pages

  16. Amacan P

    2  Pages

  17. Amacan K

    2  Pages

  18. UGS

    12  Pages

  19. ACTELEC EZ SQ

    20  Pages

  20. ACTELEC SQ AUMA

    14  Pages

  21. PumpMeter

    12  Pages

  22. KSB Sonolyzer

    5  Pages

  23. Etachrom L

    40  Pages

  24. Etanorm/Etabloc

    70  Pages

  25. AKG-A/AKGS-A

    12  Pages

  26. Amamix

    2  Pages

  27. Amaprop

    2  Pages

  28. HQ

    2  Pages

  29. BOAX-CBV13

    3  Pages

  30. Magnochem

    2  Pages

  31. Secochem Ex

    2  Pages

  32. Hya-Solo D

    44  Pages

  33. HGB, HGC

    4  Pages

  34. GZ 9

    2  Pages

  35. Etaseco

    2  Pages

  36. SuPremE

    2  Pages

  37. Etanorm

    2  Pages

  38. Etaline

    2  Pages

  39. CTN / -H

    2  Pages

  40. CINCP / CINCN

    2  Pages

  41. CHTD

    2  Pages

  42. CHTC

    2  Pages

  43. Calio S

    2  Pages

  44. AMADS

    2  Pages

  45. YNK

    2  Pages

  46. RHR/RVR

    2  Pages

  47. RHM

    2  Pages

  48. HGC

    2  Pages

  49. RPHb

    2  Pages

  50. MegaCPK

    2  Pages

  51. RPH-V

    2  Pages

  52. RDLO

    2  Pages

  53. Multitec

    2  Pages

  54. INVCP

    2  Pages

Archived catalogs

  1. Riotherm

    4  Pages

  2. PHZ

    15  Pages

  3. Ixo

    4  Pages

  4. UPA

    118  Pages

  5. MR 25 to 1600

    16  Pages

  6. Rio/Rio Z

    32  Pages

  7. Rio-Eco/Z

    24  Pages

  8. LSA-S

    4  Pages

  9. CTN

    4  Pages

  10. VTS

    4  Pages

  11. Trialine

    12  Pages

  12. Trialine Z

    12  Pages

  13. ZJSVA/ ZXSVA

    6  Pages

  14. BOA-RVK

    4  Pages

  15. MN

    4  Pages

  16. HGM

    4  Pages

  17. BOACHEM

    4  Pages

  18. HERA BD

    6  Pages

  19. BOA-H

    2  Pages

  20. BOA-CVE

    16  Pages

  21. Ama-Porter

    24  Pages

  22. Ama-Porter ICS

    16  Pages

  23. MAT-P

    4  Pages

  24. MA

    4  Pages

  25. Amaprop

    4  Pages

  26. Omega / Omega V

    56  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.