LevelControl Basic 2
36Pages

{{requestButtons}}

Catalog excerpts

LevelControl Basic 2 - 1

Level Control Unit Type Series Booklet

Open the catalog to page 1
LevelControl Basic 2 - 2

Legal information/Copyright Type Series Booklet LevelControl Basic 2 All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed for any other purpose, nor otherwise transmitted, published or made available to a third party without the manufacturer's express written consent. Subject to technical modification without prior notice. © KSB SE & Co. KGaA, Frankenthal 12/06/2019

Open the catalog to page 2
LevelControl Basic 2 - 4

Pump Switchgear / Control Systems LevelControl Control Units Pump Switchgear / Control Systems LevelControl Control Units ■ Amarex N ■ Amarex KRT ■ CK pump stations (LevelControl Basic 2 included in the scope of supply in some cases) ■ mini-Compacta / Compacta (LevelControl Basic 2 included in the scope of supply) ■ Sewatec / Sewabloc ■ Etaline ■ Etanorm / Etabloc ■ Other pumps on request LevelControl Basic 2 is available in 2 variants: ■ Type Basic Compact (plastic housing) ■ Type Basic Control Cabinet (sheet steel housing) Type Basic Compact (BC) Pump control and monitoring unit with...

Open the catalog to page 4
LevelControl Basic 2 - 5

Pump Switchgear / Control Systems LevelControl Control Units 3) Higher ratings on request.

Open the catalog to page 5
LevelControl Basic 2 - 6

Pump Switchgear / Control Systems LevelControl Control Units Product benefits ▪ Ample connection space allows straightforward connection of pumps and sensors ▪ Reliability provided by detailed information on the display, including key measurement values and parameters as well as "in operation" and general fault indication per pump ▪ Comprehensive functionality for high system availability Selection information Lightning protection ▪ Electrical installations must be protected against overvoltage (binding since 14 December 2018) (see DIN VDE 0100-443 (IEC 60364-4-44:2007/A1:2015, modified)...

Open the catalog to page 6
LevelControl Basic 2 - 7

Pump Switchgear / Control Systems LevelControl Control Units Technical data o The control unit is selected on the basis of the nominal current of the pump. Higher currents and power ratings are available on request. o The standard variant of LevelControl Basic 2 is not suitable for use in IT mains. Variants for IT mains are available on request. 0 For the following special voltages (3~ only) LevelControl Basic 2 can be configured via KSB EasySelect: ■ 208 V, 220 V, 230 V, 380 V, 415 V, 440 V, 460 V, 480 V, 500 V Technical data Technical specifications for sensors 4 float switches / digital...

Open the catalog to page 7
LevelControl Basic 2 - 8

Pump Switchgear / Control Systems LevelControl Control Units Battery life: ▪ Approx. 10 hours when supplying the integrated piezo buzzer 85 dB(A), electronics, and sensors ▪ Approx. 4 hours when supplying external alarm equipment (e.g. horn, alarm combination, or alarm strobe light) Charging time: ▪ Approx. 11 hours (if battery is fully discharged) Dimensions and weights Dimensions and weights Type Nominal current per pump ATEX-compliant version with float

Open the catalog to page 8
LevelControl Basic 2 - 9

Pump Switchgear / Control Systems LevelControl Control Units LevelControl Basic 2 for Ama-Drainer Documented device versions Control units for single-pump station

Open the catalog to page 9
LevelControl Basic 2 - 10

Pump Switchgear / Control Systems LevelControl Control Units

Open the catalog to page 10
LevelControl Basic 2 - 11

Pump Switchgear / Control Systems LevelControl Control Units Ama-Drainer with control unit type BC 1~230 V: Ama-Drainer N 301/302/303, Ama-Drainer N 358, Ama-Drainer NE 4../5.., Ama-Porter NE J203

Open the catalog to page 11
LevelControl Basic 2 - 12

Pump Switchgear / Control Systems LevelControl Control Units Fig. 2: Circuit diagram: Ama-Drainer ND 4.. / 5.

Open the catalog to page 12
LevelControl Basic 2 - 13

Pump Switchgear / Control Systems LevelControl Control Units

Open the catalog to page 13
LevelControl Basic 2 - 14

Pump Switchgear / Control Systems LevelControl Control Units LevelControl Basic 2 for Ama-Porter Documented device variants Control units for single-pump station Size Float switch incl. 4 - 20 mA input Bubbler control Control units for dual-pump station Size Float switch incl. 4 - 20 mA input Bubbler control Functional comparison Symbols key Symbol Digital display of switching points Optional Control unit feature Not a control unit feature Comparison of functions of Ama-Porter single-pump stations and dual-pump stations Dual-pump station DLNO (BC housing) DFNO Functions Draining Filling...

Open the catalog to page 14
LevelControl Basic 2 - 15

Pump Switchgear / Control Systems LevelControl Control Units

Open the catalog to page 15
LevelControl Basic 2 - 16

Pump Switchgear / Control Systems LevelControl Control Units Ama-Porter with control unit type BCAma-Porter NE 1

Open the catalog to page 16
LevelControl Basic 2 - 17

Pump Switchgear / Control Systems LevelControl Control Units

Open the catalog to page 17
LevelControl Basic 2 - 18

Pump Switchgear / Control Systems LevelControl Control Units LevelControl Basic 2 for Amarex N Non-ATEX-compliant versions Documented device versions Control units for single-pump station, non-ATEX-compliant

Open the catalog to page 18
LevelControl Basic 2 - 19

Pump Switchgear / Control Systems LevelControl Control Units

Open the catalog to page 19
LevelControl Basic 2 - 20

Pump Switchgear / Control Systems LevelControl Control Units ATEX-compliant versions o control units are not explosion-proof, which means that they must not be operated in potentially explosive atmospheres. Analog intrinsic safety barriers are required in ATEX-compliant versions for 4 - 20 mA (see Optional components). Selection via KSB EasySelect. Control units for single-pump station, ATEX-compliant version

Open the catalog to page 20
LevelControl Basic 2 - 21

Pump Switchgear / Control Systems LevelControl Control Units 5) Additional intrinsic safety barrier required for high water float switch (see "Optional components")

Open the catalog to page 21
LevelControl Basic 2 - 22

Pump Switchgear / Control Systems LevelControl Control Units Amarex N with control unit type BC Amarex N J203

Open the catalog to page 22
LevelControl Basic 2 - 23

Pump Switchgear / Control Systems LevelControl Control Units LevelControl Basic 2 for Amarex KRT Documented device versions Control units for single-pump station, ATEX-compliant version

Open the catalog to page 23
LevelControl Basic 2 - 24

Pump Switchgear / Control Systems LevelControl Control Units 6) Additional intrinsic safety barrier required for high water float switch (see Optional components) 7) Analog intrinsic safety barriers are required in ATEX-compliant versions for 4 - 20 mA (see Optional components). Selection via KSB EasySelect. 8) Additional intrinsic safety barrier for redundant high water float switch in variants for pneumatic and bubbler control

Open the catalog to page 24
LevelControl Basic 2 - 25

Pump Switchgear / Control Systems LevelControl Control Units Amarex KRT with control unit type BC Fig. 7: Circuit diagram Amarex KRT

Open the catalog to page 25
LevelControl Basic 2 - 26

Pump Switchgear / Control Systems LevelControl Control Units

Open the catalog to page 26

All KSB S.A.S. - France catalogs and technical brochures

  1. ACTAIR

    8 Pages

  2. BOA-R

    16 Pages

  3. Amaline

    2 Pages

  4. ISORIA

    2 Pages

  5. AMTROBOX

    12 Pages

  6. Ama-Porter

    36 Pages

  7. AKR/AKRS

    12 Pages

  8. AKG-A/AKGS-A

    16 Pages

  9. ACTAIR NG

    28 Pages

  10. ACTELEC

    22 Pages

  11. Amacan S

    2 Pages

  12. Amacan P

    2 Pages

  13. Ama-Porter S

    24 Pages

  14. Amamix

    2 Pages

  15. Amaprop

    2 Pages

  16. Hya-Rain

    2 Pages

  17. CHTR

    8 Pages

  18. Vitalobe ®

    2 Pages

  19. SISTO

    2 Pages

  20. GZ

    2 Pages

  21. CHTC

    2 Pages

  22. NQ

    2 Pages

  23. Amacan K

    2 Pages

  24. AmaDS³

    2 Pages

  25. SET 100

    2 Pages

Archived catalogs

  1. Ama-Porter

    36 Pages