Submersible Motor Pump Type Series Booklet
Open the catalog to page 1Legal information/Copyright Type Series Booklet Ama-Porter All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed for any other purpose, nor otherwise transmitted, published or made available to a third party without the manufacturer's express written consent. Subject to technical modification without prior notice. © KSB Aktiengesellschaft, Frankenthal 05.09.2014
Open the catalog to page 2Building Services: Drainage Drainage Pumps/Waste Water Pumps Building Services: Drainage Drainage Pumps/Waste Water Pumps Ama-Porter Design details Design ■ Fully floodable submersible motor pump ■ Close-coupled design ■ Vertical installation ■ Single-stage Installation types ■ Wet-installed stationary pump sets ■ Wet-installed transportable pump sets Shaft seal Drive end Main applications ■ Drainage systems ■ Water extraction ■ Drainage Fluids handled ■ Grey water ■ Waste water containing long fibres and solid substances ■ Gas-containing fluids ■ Shaft seal ring Pump end ■ 1 bi-directional...
Open the catalog to page 5Building Services: Drainage Drainage Pumps/Waste Water Pumps Coating and preservation Primer and top coat Surface Blasted to SA 2 ’/2 to DIN EN ISO 12944 treatment: Top coat: Two-component high-solid epoxy resin finish (RAL 5002), min. layer thickness = 75 ^m Motor absolutely watertight, also in the event of damage to the cable sheath and core insulation, with individually stripped, tinned and resin-sealed conductors High operating reliability due to dry, pressure-tight and encapsulated squirrel-cage motor, thermal class F Three-phase motor: protected against overheating even under...
Open the catalog to page 6Building Services: Drainage Drainage Pumps/Waste Water Pumps Standard variants 2) Maximum switching frequency: 15 starts per hour 3) Optional: 20 m
Open the catalog to page 7Building Services: Drainage Drainage Pumps/Waste Water Pumps Technical data
Open the catalog to page 8Building Services: Drainage Drainage Pumps/Waste Water Pumps
Open the catalog to page 9Building Services: Drainage Drainage Pumps/Waste Water Pumps Characteristic curves Ama-Porter 5 _ _; n = 2900 rpm; F impeller Characteristic curves to ISO 9906 Class 2A / 3B, below 10 kW to § 4.4.2. The curves refer to the effective motor speed. 0 0
Open the catalog to page 10Building Services: Drainage Drainage Pumps/Waste Water Pumps Ama-Porter 6 _ _; n = 2900 rpm; F impeller Characteristic curves to ISO 9906 Class 2A / 3B, below 10 kW to § 4.4.2. The curves refer to the effective motor speed. 0
Open the catalog to page 11Building Services: Drainage Drainage Pumps/Waste Water Pumps Ama-Porter S 545; n = 2900 rpm; S impeller Characteristic curves to ISO 9906 Class 2A / 3B, below 10 kW to § 4.4.2. The curves refer to the effective motor speed. 0
Open the catalog to page 12Building Services: Drainage Drainage Pumps/Waste Water Pumps Dimensions Ama-Porter 5 _ _, F impeller, transportable wet-installed model 128 Lowest switch-off point Hose inner diameter: 63 mm Ama-Porter 6 _ _, F impeller, transportable wet-installed model 128 Lowest switch-off point Hose inner diameter: 80 mm
Open the catalog to page 13Building Services: Drainage Drainage Pumps/Waste Water Pumps Ama-Porter S 545, S impeller, transportable wet-installed model 128 Lowest switch-off point Hose inner diameter: 63 mm
Open the catalog to page 14Building Services: Drainage Drainage Pumps/Waste Water Pumps Ama-Porter 5__, F impeller, stationary wet-installed model with guide wire/guide hoop, duckfoot bend DN 50/50 Ama-Porter 6__, F impeller, stationary wet-installed model with guide wire/guide hoop, duckfoot bend DN 65/65
Open the catalog to page 15KSB Building Services: Drainage Drainage Pumps/Waste Water Pumps Ama-Porter S 545, S impeller, stationary wet-installed model with guide wire/guide hoop, duckfoot bend DN 50/50 Ama-Porter 5__, F impeller, stationary wet-installed model with guide wire/guide hoop, straight pump foot G 2"
Open the catalog to page 16Building Services: Drainage Drainage Pumps/Waste Water Pumps Ama-Porter 6__, F impeller, stationary wet-installed model with guide wire/guide hoop, straight pump foot G 2%" Ama-Porter S 545, S impeller, stationary wet-installed model with guide wire/guide hoop, straight pump foot G 2"
Open the catalog to page 17Building Services: Drainage Drainage Pumps/Waste Water Pumps Ama-Porter 5 _ _, F impeller, stationary wet-installed model with single guide rail, duckfoot bend DN 50/50 Lowest switch-off point Flange of duckfoot bend Ama-Porter 6 _ _, F impeller, stationary wet-installed model with single guide rail, duckfoot bend DN 65/65 85 Lowest switch-off point
Open the catalog to page 18Building Services: Drainage Drainage Pumps/Waste Water Pumps Ama-Porter S 545, S impeller, stationary wet-installed model with single guide rail, duckfoot bend DN 50/50 ISO 7005 PN 16 DN 50 PN 16 ASME 2” 120 Lowest switch-off point Flange of duckfoot bend Ama-Porter 5 _ _, F impeller, stationary wet-installed model with single guide rail, straight pump foot G 2" 76 Lowest switch-off point
Open the catalog to page 19Building Services: Drainage Drainage Pumps/Waste Water Pumps Ama-Porter 6 _ _, F impeller, stationary wet-installed model with single guide rail, straight pump foot G 2 ½" 12 Lowest switch-off point Ama-Porter S 545, S impeller, stationary wet-installed model with single guide rail, straight pump foot G 2" 76 Lowest switch-off point
Open the catalog to page 20Building Services: Drainage Drainage Pumps/Waste Water Pumps Ama-Porter 5 _ _, F impeller, stationary wet-installed model with twin guide rails, duckfoot bend DN 50/50 Lowest switch-off point Flange of duckfoot bend Ama-Porter 6 _ _, F impeller, stationary wet-installed model with twin guide rails, duckfoot bend DN 65/65 Lowest switch-off point Flange of duckfoot bend
Open the catalog to page 21Building Services: Drainage Drainage Pumps/Waste Water Pumps Ama-Porter S 545, S impeller, stationary wet-installed model with twin guide rails, duckfoot bend DN 50/50 Sump - Ama-Porter 5 _ _/6 _ _, F impeller / Ama-Porter S 545, S impeller
Open the catalog to page 22Building Services: Drainage Drainage Pumps/Waste Water Pumps Information on installation Suggested electrical installation layouts Ama-Porter is available in non-explosionproof design. Ama-Porter 5 _ _ / 6 _ _ E50 E51 E52 E53 Suggested installation layout No. 1 Suggested installation layout No. 2 Suggested installation layout No. 1 Suggested installation layout No. 2
Open the catalog to page 23All KSB S.A.S. - France catalogs and technical brochures
-
ACTAIR
8 Pages
-
BOA-R
16 Pages
-
Amaline
2 Pages
-
Cervomatic EDP.2
30 Pages
-
ISORIA
2 Pages
-
UGS Type Series Booklet
12 Pages
-
AMTROBOX
12 Pages
-
Ama-Porter
36 Pages
-
AKR/AKRS
12 Pages
-
AKG-A/AKGS-A
16 Pages
-
ACTAIR NG
28 Pages
-
LevelControl Basic 2
36 Pages
-
Pumps ı Automation
76 Pages
-
ACTELEC
22 Pages
-
1/4 turn ACTELEC LEA and LEB
4 Pages
-
Ama-Drainer-Box
12 Pages
-
BOA-Control SAR
8 Pages
-
Amacan S
2 Pages
-
Amacan P
2 Pages
-
Ama-Porter 60 Hz
30 Pages
-
Ama-Porter S
24 Pages
-
Ama-Porter CK-Pumpstation
18 Pages
-
Ama-Drainer-Box Mini
2 Pages
-
Ama-Drainer-Box
2 Pages
-
Ama-Drainer N
2 Pages
-
Ama-Drainer 80, 100
20 Pages
-
Ama-Drainer 4../5..
36 Pages
-
Amamix
2 Pages
-
Amaprop
2 Pages
-
Pumps and Automation
68 Pages
-
The Range of Valves
69 Pages
-
Hya-Rain
2 Pages
-
HGC – Boiler feed pump
2 Pages
-
CHTR
8 Pages
-
Amaline – Submersible Pump
2 Pages
-
Sewatec/Sewabloc
2 Pages
-
Vitalobe ®
2 Pages
-
SISTO
2 Pages
-
GZ
2 Pages
-
CHTC
2 Pages
-
NQ
2 Pages
-
Amacan K
2 Pages
-
AmaDS³
2 Pages
-
product description Movitec
2 Pages
-
SET 100
2 Pages
-
Product publication LUVA
8 Pages
-
Product introduction LUS
2 Pages
-
product description_Multitec
2 Pages
-
Tubular Casing Pumps by KSB.
16 Pages
-
HGM – For good reason
4 Pages
-
The Range of Valves 2010
58 Pages
-
Pumps and Automation 2010
54 Pages