Ama-Drainer 4../5.. - 1

Submersible Waste Water Pump Type Series Booklet

Open the catalog to page 1
Ama-Drainer 4../5.. - 2

Legal information/Copyright Type Series Booklet Ama-Drainer 4../5.. All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed for any other purpose, nor otherwise transmitted, published or made available to a third party without the manufacturer's express written consent. Subject to technical modification without prior notice. © KSB Aktiengesellschaft, Frankenthal 08.01.2016

Open the catalog to page 2
Ama-Drainer 4../5.. - 4

Building Services: Drainage Drainage Pumps/Waste Water Pumps Operating data Operating properties Building Services: Drainage Drainage Pumps/Waste Water Pumps Main applications ■ Drainage ■ Disposal ■ Drainage systems ■ Lowering groundwater levels ■ Maintaining groundwater levels Fluids handled ■ Slightly contaminated water ■ Waste water containing long fibres and stringy material ■ Seawater ■ Swimming-pool water ■ Brackish water ■ Oil emulsions and cutting oils ■ Waste water containing oil Designation Example: Ama-Drainer A 4 22 S D / 10 K Designation key Design details Design ■ Fully...

Open the catalog to page 4
Ama-Drainer 4../5.. - 5

■ Integrated temperature switch ■ 10-metre power cable ■ Shock-proof plug Ama-Drainer /10, /11 and /35 SD ■ Three-phase motor ■ Integrated temperature switch ■ 10-metre power cable ■ CEE plug (3L+PE+N) incl. motor contactor and phase inverter Ama-Drainer /10, /11 and /35 ND ■ Three-phase motor ■ Integrated temperature switch ■ 10-metre power cable with free cable end and protective cap Shaft seal ■ Pump end: 1 bi-directional mechanical seal ■ Drive end: 1 shaft seal ring ■ A lubricant reservoir in-between the seal elements ensures cooling and lubrication. Impeller type ■ Open multi-channel...

Open the catalog to page 5
Ama-Drainer 4../5.. - 7

Selection table The table listing fluids handled is a selection tool for drainage duties. It should be used for orientation and is based on KSB's many years of experience. The data are reference values and should not be considered to be generally binding recommendations. They shall not be the basis for warranty claims. Please contact your nearest KSB sales branch and/or our technical departments for in-depth advice. Table of fluids handled 2) Please contact KSB and provide the relevant analysis as well as the data on temperature and mode of operation

Open the catalog to page 7
Ama-Drainer 4../5.. - 8

Drainage Pumps/Waste Water Pumps

Open the catalog to page 8
Ama-Drainer 4../5.. - 9

Building Services: DrainageDrainage Pumps/Waste Water PumpsTechnical dataMaterial variant A Designation

Open the catalog to page 9
Ama-Drainer 4../5.. - 10

Building Services: Drainage Drainage Pumps/Waste Water Pumps

Open the catalog to page 10
Ama-Drainer 4../5.. - 11

Building Services: Drainage Drainage Pumps/Waste Water Pumps Characteristic curves Ama-Drainer 4../5..; n = 2800 rpm; multi-vane impeller 0 Free passage: 405/407/411/415/422/505/507/511/515 = 10 mm, 522 = 11 mm Performance tolerance to ISO 2548 Class C (water under standard conditions)

Open the catalog to page 11
Ama-Drainer 4../5.. - 12

Building Services: Drainage Drainage Pumps/Waste Water Pumps Ama-Drainer 4..; n = 2800 rpm; F impeller 0 0 Free passage: 405/411/422 = 35 mm Performance tolerance to ISO 2548 Class C (water under standard conditions)

Open the catalog to page 12
Ama-Drainer 4../5.. - 13

Building Services: Drainage Drainage Pumps/Waste Water Pumps Dimensions Outline drawings 4../10 without cooling jacket 5../10K with cooling jacket 4../35 without cooling jacket 522/11 without cooling jacket

Open the catalog to page 13
Ama-Drainer 4../5.. - 14

4.. NE/10 without cooling jacket 522 ND/11 without cooling jacket

Open the catalog to page 14
Ama-Drainer 4../5.. - 15

Building Services: DrainageDrainage Pumps/Waste Water PumpsExamples of stationary installation 522 ND/11 with guide hoop 522 ND/11 with guide wire

Open the catalog to page 15
Ama-Drainer 4../5.. - 16

Building Services: DrainageDrainage Pumps/Waste Water PumpsOutline drawings of single pumps 4..SE/10 without cooling jacket

Open the catalog to page 16
Ama-Drainer 4../5.. - 17

Building Services: Drainage Drainage Pumps/Waste Water Pumps Typical arrangement of dual-pump station 405 ... 422 NE/ND / 505 ... 522 NE/ND E 70

Open the catalog to page 17
Ama-Drainer 4../5.. - 18

Building Services: Drainage Drainage Pumps/Waste Water Pumps Pump accessories 3) (x) = increasing or reducing adapters are required for these nominal diameters

Open the catalog to page 18
Ama-Drainer 4../5.. - 19

Drainage Pumps/Waste Water Pumps 3) (x) = increasing or reducing adapters are required for these nominal diameters

Open the catalog to page 19
Ama-Drainer 4../5.. - 20

Drainage Pumps/Waste Water Pumps 3) (x) = increasing or reducing adapters are required for these nominal diameters

Open the catalog to page 20
Ama-Drainer 4../5.. - 21

Building Services: Drainage Drainage Pumps/Waste Water Pumps Control units and switchgear Valid for all countries except France Dimensions (W x H x D) 100 x 170 x 112 mm CEE motor protection plug, type Hyper4) With integrated motor protection relay, manual-0-automatic selector switch and motor contactor, operation and fault indicator lamps Float switch Dimensions (W x H x D) 100 x 170 x 112 mm Motor protection switchgear MSD With integrated motor protection ✘ relay, manual-0-automatic selector switch and motor ✘ contactor, operation and fault indicator lamps Motor protection switchgear MSE...

Open the catalog to page 21
Ama-Drainer 4../5.. - 22

Drainage Pumps/Waste Water Pumps Optional components are not EDI-compatible (configurable range) Operation with mini control system For operation with mini control systems, separate float switches and appropriate cable lengths must be ordered with Ama-Drainer 405 NE to 415 NE or 505 NE to 515 NE since the float switch directly mounted on the S variant cannot be connected to the mini control system. LevelControl with float switches: Single pump: ■ At least 1 float switch for pump On/Off ■ At least 2 float switches for pump On/Off and high water alert Dual pump: ■ At least 2 float switches...

Open the catalog to page 22
Ama-Drainer 4../5.. - 23

. Valid for all countries except France.

Open the catalog to page 23
Ama-Drainer 4../5.. - 24

Drainage Pumps/Waste Water Pumps

Open the catalog to page 24
Ama-Drainer 4../5.. - 25

Building Services: DrainageDrainage Pumps/Waste Water PumpsControl units and switchgear . Only valid for France! 6) Required for Ama-Drainer ND only

Open the catalog to page 25
Ama-Drainer 4../5.. - 27

Drainage Pumps/Waste Water Pumps

Open the catalog to page 27
Ama-Drainer 4../5.. - 28

Building Services: Drainage Drainage Pumps/Waste Water Pumps Single-pump station Float switch(es) incl. 4...20 mA Dual-pump station Float switch(es) incl. 4...20 mA

Open the catalog to page 28
Ama-Drainer 4../5.. - 30

Building Services: DrainageDrainage Pumps/Waste Water PumpsControl unit/switchgear accessories

Open the catalog to page 30
Ama-Drainer 4../5.. - 31

Building Services: Drainage Drainage Pumps/Waste Water Pumps

Open the catalog to page 31
Ama-Drainer 4../5.. - 32

Building Services: Drainage Drainage Pumps/Waste Water Pumps General assembly drawings with list of components General assembly drawing Ama-Drainer .../10, .../10K,.../35 General assembly drawing of Ama-Drainer .../10, .../10K, .../35 Description Foot/suction cover assembly (for .../35) Pump casing, complete Volute casing Protective casing Suction cover Comprises: Suction cover 162, foot 182, intermediate ring 509 Pump casing 101, joint ring 411, O-ring 412.01, hexagon socket head cap screw 914.01 Volute casing 102, O-ring 412.05, intermediate ring 509 Protective casing 13-16 Suction cover...

Open the catalog to page 32

All KSB S.A.S. - France catalogs and technical brochures

  1. ACTAIR

    8 Pages

  2. BOA-R

    16 Pages

  3. Amaline

    2 Pages

  4. ISORIA

    2 Pages

  5. AMTROBOX

    12 Pages

  6. Ama-Porter

    36 Pages

  7. AKR/AKRS

    12 Pages

  8. AKG-A/AKGS-A

    16 Pages

  9. ACTAIR NG

    28 Pages

  10. ACTELEC

    22 Pages

  11. Amacan S

    2 Pages

  12. Amacan P

    2 Pages

  13. Ama-Porter S

    24 Pages

  14. Amamix

    2 Pages

  15. Amaprop

    2 Pages

  16. Hya-Rain

    2 Pages

  17. CHTR

    8 Pages

  18. Vitalobe ®

    2 Pages

  19. SISTO

    2 Pages

  20. GZ

    2 Pages

  21. CHTC

    2 Pages

  22. NQ

    2 Pages