automatic Filter
20Pages

{{requestButtons}}

Catalog excerpts

automatic Filter - 1

Application Report KAF (selbstreinigender Filter / automatic Filter / backflush filter) Krone Filter SOLUTIONS IN FILTRATION info@krone-filter.com www.krone-filter.com Kunde / Customer: Aufgabenstellung / Scope of filtration Filtration of impurities: Verunreinigung durch / Filtration of: Durchsatz / Flowrate: Temperature design: Druck / Working press: Rohrleitung / Piping: Filter: Filterfeinheit / Filtration degree: REMARKS: Power Plant in Egypt Filtration of raw Nil riverwater river water 1800-3300 m3/h 0-65 °C 2-4,5 bar DN/NW 24" CS unit with 6,4 mm rubberlining KAF Bernoulli 24" ANSI 150 lbs Carbon Steel with 6,4 mm rubberlining Design acc. ASME VIII Div. 1 with U-Stamp SPS Steuerung/Electronic control panel (PLC) 0,5 mm 2 pcs. With ASME U-Stamp, electric piston drive, 6,4 mm rubberlining

Open the catalog to page 1
automatic Filter - 2

Krone Filter SOLUTIONS IN FILTRATION info@krone-filter.com www.krone-filter.com Stahlwerk / Steel Work Kunde / Customer: Aufgabenstellung / Filtration von Kreislauf Kuhlwasser Scope of filtration: Cooling water filtration Filtration of: Sintering coal Durchsatz / Flowrate: Temperature: Druck / Working press:Rohrleitung / Piping:Filter: KAF Bernoulli DN 80 / NW 80 PN 16Gehause 1.4571 / Housing 316 Ti SPS Steuerung/Electronic control panel (PLC) Filterfeinheit / Filtration degree: 200 micron •A9a-a9-dd-oioe-80-||Dd d>l

Open the catalog to page 2
automatic Filter - 3

Krone Filter SOLUTIONS IN FILTRATION info@krone-filter.com www.krone-filter.com Application Report KAF (selbstreinigender Filter / automatic Filter / backflush filter) Kunde / Customer: Hersteller von Fussboden-Laminat-Platten Aufgabenstellung: Filtration von Kreislaufwasser aus Luftwascher (Spanplatten und Laminatplatten werden geschnitten und die Abluft enthalt grofie Mengen Staube, Spane und Fasern. Diese werden mit Wasser im Luftwascher gebunden). Verunreinigung durch: Laminatreste, Staube und Fasern Druck / Working press: 6 bar Filter: KAF Bernoulli DN 80 PN 16 Gehause 1.4571 SPS...

Open the catalog to page 3
automatic Filter - 4

Application Report info@krone-filter.com www.krone-filter.com KAF (2 units automatic Filter) Laminate production Aufgabenstellung / Scope of filtration: Filtration von Kreislauf Kühlwasser Cooling water filtration Verunreinigung durch / Filtration of: Fasern aus Laminatproduktion Fibres in Laminate production / cooling water Durchsatz / Flowrate: Temperature: Druck / Working press: Rohrleitung / Piping: KAF Bernoulli DN 80 / NW 80 PN 16 Gehäuse 1.4571 / Housing 316 Ti SPS Steuerung/Electronic control panel (PLC) Filterfeinheit / Filtration degree: Kunde / Customer: 08.2010 © by Krone Filter...

Open the catalog to page 4
automatic Filter - 5

Application Report KAF (selbstreinigender Filter / automatic Filter / backflush filter) Krone Filter SOLUTIONS IN FILTRATION info@krone-filter.com www.krone-filter.com Kunde / Customer: Biomasse Kraftwerk/Biomass Power Plant Aufgabenstellung / Filtration von Kuhlturm Kreislauf Kuhlwasser Scope of filtration Cooling tower water filtration Verunreinigung durch / Filtration of: Durchsatz / Flowrate: Temperature design: Druck / Working press: Rohrleitung / Piping: Offene Kuhlturme/Impurities of open cooling towers Gehause GFK/FRP/Housing FRP/GRP SPS Steuerung/Electronic control panel (PLC)...

Open the catalog to page 5
automatic Filter - 6

Application Report KAF (selbstreinigender Filter / automatic filter / backflush filter) Krone Filter SOLUTIONS IN FILTRATION info@krone-filter.com www.krone-filter.com Kunde / Customer: Aufgabenstellung / Scope of filtration Filtration of impurities: Verunreinigung durch / Filtration of: Durchsatz / Flowrate: Temperature design: Druck / Working press: Rohrleitung / Piping: Filter: Filterfeinheit / Filtration degree: REMARKS: QAFCO fertilizer Qatar Chemical Industry raw seawater 800-1000 m3/h 0-65 °C 2-5,5 bar 14" GRP KAF Bernoulli GRP with ASME X approval 1 mm Titanium insert and wetted...

Open the catalog to page 6
automatic Filter - 7

Application Report KAF (selbstreinigender Filter / automatic filter / backflush filter) Krone Filter SOLUTIONS IN FILTRATION info@krone-filter.com www.krone-filter.com Kunde / Customer: Aufgabenstellung / Scope of filtration Filtration of impurities: Verunreinigung durch / Filtration of: Durchsatz / Flowrate: Temperature design: Druck / Working press: Rohrleitung / Piping: Filter: Filterfeinheit / Filtration degree: REMARKS: largest chlor manufacturing company in the world Chemical Industry sewage plant sewage 200-300 m3/h 0-65 °C 2-5,5 bar 8" KAF Bernoulli GRP acc. ASME X SPS...

Open the catalog to page 7
automatic Filter - 8

Application Report info@krone-filter.com www.krone-filter.com KAF (selbstreinigender Filter / automatic Filter / backflush filter) Brauerei Abwasser Recycling Filtration von Abwässern einer Brauerei Verunreinigung durch: Etiketten, Korkenreste, Metall Abrieb, Kunststoffpartikel sowie Reste von Zigarettenfiltern Durchsatz / Flowrate: Temperature: Druck / Working press: Rohrleitung / Piping: KAF Bernoulli DN 80 PN 10/GFK (Gehäusewerkstoff) SPS Steuerung (Zeit und differenzdruckgesteuert) Filterfeinheit / Filtration degree: Kunde / Customer: 08.2010 © by Krone Filter Solutions GmbH, subject to ch

Open the catalog to page 8
automatic Filter - 9

Application Report KAF (selbstreinigender Filter / automatic Filter / backflush filter) Krone Filter SOLUTIONS IN FILTRATION info@krone-filter.com www.krone-filter.com Kunde / Customer: Biomasse Kraftwerk/Biomass Power Plant Aufgabenstellung / Filtration von Kuhlturm Kreislauf Kuhlwasser Scope of filtration Cooling tower water filtration Verunreinigung durch / Offene Kuhlturme Filtration of: Impurities of open cooling towers Durchsatz / Flowrate: Temperature design: Druck / Working press: Rohrleitung / Piping: Gehause GFK/FRP/Housing FRP/GRP SPS Steuerung/Electronic control panel (PLC)...

Open the catalog to page 9
automatic Filter - 10

Krone Filter SOLUTIONS IN FILTRATION info@krone-filter.com www.krone-filter.com Application Report KAF (selbstreinigender Filter / automatic Filter / backflush filter) Kunde / Customer: Aufgabenstellung / Scope of filtration Filtration of impurities: Verunreinigung durch / Filtration of: Durchsatz / Flowrate: Temperature design: Druck / Working press: Rohrleitung / Piping: Filter: Filterfeinheit / Filtration degree: REMARKS: Power Plant in north Africa Filtration of raw seawater river water 1000-1600 m3/h 0-65 °C 5,2-6,5 bar DN/NW 16" CS unit with 6,4 mm rubberlining 4 x KAF Bernoulli 16"...

Open the catalog to page 10

All Krone Filter Solutions GmbH catalogs and technical brochures

  1. KMF

    12 Pages

  2. KRF

    18 Pages

  3. KSF

    14 Pages

  4. KWF

    6 Pages

  5. DP-MAG

    4 Pages

  6. KBF-M

    6 Pages

  7. KDF-V

    12 Pages

  8. KDF-K

    14 Pages

  9. KAF Bernoulli

    14 Pages

  10. KBF

    6 Pages

  11. KDF-K

    6 Pages

  12. KBF