Group: Krohne
Catalog excerpts
The universal 3-beam in-line ultrasonic flowmeter for liquids • Independant of conductivity, viscosity, temperature, density and pressure • No moving or intruding parts, therefore no pressure Loss or wear • Minimal operational and maintenance costs
Open the catalog to page 1Standard solution in the process industry UFM 3030 is a 3-beam ultrasonic flowmeter for liquids. UFM 3030 measures independent of conductivity, viscosity, temperature, density and pressure. • Three beams generate a measurement effectively independent of flow profile • Major performance improvement by applying innovative electronics and digital signal • Optional pressure and temperature inputs for calculation of standardised volumetric flow or mass flow according to API 2540 or customer • Over 20.000 ultrasonic flowmeters installed • Easy to install and operate • No moving or intruding...
Open the catalog to page 2nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn UFM 3030 In-line Ultrasonic process flowmeter family The UFM 3030 liquid process flowmeter consists of a UFS 3000 flow sensor and a flow converter, UFC 030. A UFS 3000 flow sensor can be build together with a UFC 030 flow converter as a compact flowmeter or can be installed separate as a field version. UFC 030 flow converter 1 The flowconverter is fully digital and fitted with a digital signal processor and advanced software for optimal performance 2 For in-depth analysis of application and evaluation of flowmeter performance, the soundcheck...
Open the catalog to page 3UFM 3030 nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn Technical data Versions UFM 3030 K (Compact version) UFC 030 K ultrasonic flow converter directly mounted on the UFS 3000 ultrasonic flow sensor UFM 3030 F (Separate version) UFC 030 F ultrasonic flow converter is remotely mounted from the UFS 3000 ultrasonic flow sensor Performance Measurement functionality Actual volume with simple single stage batching function (standard) Corrected or standardized volume flow rate to API 2540 or customer specified (optional) Customer specified mass flow (requires customer data) (optional) Thermal...
Open the catalog to page 4nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn UFM 3030 Temperature range Process temp. [ºC] min. Ambient temp. [ºC] max. min. max. XT version* -25 220 -40 HT version ** -170 500 -40 65 65 * Up to DN 150/6" only. ** special version on request only Temperature range Process temp. [ºF] min. Ambient temp. [ºF] max. min. max. Compact -13 284 -40 149 Separate -13 356 -40 149 XT version* -13 428 -40 149 HT version** -274 932 -40 149 * Up to DN 150/6" only. ** Special version on request only 4" 5" 6" 8" 10" 12" 14" 16" 18" 20" 24" 28" 32" 36" 100 125 150 200 250 300 350 400 450 500 600 700 800...
Open the catalog to page 5UFM 3030 nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 4" 5" 6" 8" 10" 12" 14" 16" 18" 20" 24" 28" 32" 36" 100 125 150 200 250 300 350 400 450 500 600 700 800 900 2000 80" 3" 80 1800 72" 2,5" 65 1600 64" 2" 50 1400 56" 1,5" 40 DN [mm] 1200 48" 11/4" 32 ASME [inch] 1000 40" 1" 25 Nominal diameter Connection box - Aluminum, polyurethane coated - Stainless steel Transducer window - Stainless steel 1.4408 (AISI 316 L) * Individual external transducer housing. Finish Standard paint, silver Offshore paint system, silver Other paint systems on request. Calibration On 2 points, with water...
Open the catalog to page 6nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn UFM 3030 UFC 030 converter General The converter has a backlit local display with three push buttons. All operation can be done by push button or using a hand-held bar magnet, without opening the converter housing. Applied materials Converter housing - Die-cast aluminum Standard - Stainless steel 316 L (1.4404) Option Finish Standard paint, silver Standard Offshore paint system, silver Option Other paints on request Protection category IP 67 eq. NEMA 6 Standard to IEC 529 Functionality Continuous measurement of actual Standard volume flow...
Open the catalog to page 7UFM 3030 nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn Option Corrected standard volume total in m3, barrels, liters, US Gallons or user defined corrected volume unit, minimum 1 year overflow time Option Calculated mass total in user defined unit, minimum 1 year overflow time Option Analog input in °C, °F, bar or psig Option Thermal power Option Thermal energy totalized Languages - English Standard - German Standard - French Standard Galvanic isolation Standard All inputs and outputs are galvanically isolated from the power supply, but not from each other Optional Namur NE 43,...
Open the catalog to page 8nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn UFM 3030 Standard Actual volume Option Corrected or standardized volume to API 2540 or customer specified Option Customer specified mass (requires customer specific density input) Option Thermal energy measurement Frequency output Pulse rate Standard Continuous measurement of actual volume flow rate Standard Velocity Of Sound (VOS) Standard Transducer signal gain (dB) Standard Pressure or temperature indication based on analog input (1) or (2) Option Corrected or standardized volume flow rate to API 2540 or customer specified Option Customer...
Open the catalog to page 9UFM 3030 nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn Input A2 4...20 mA for temperature Active (using UFC 030 24 V DC power) or passive, Load 58 Ohm Control input Function Option Reset totalizer Option Acknowledge errors Option Force outputs to zero Option Initiate batch (see operating instructions for description of this function) Setting On or Off Connection Input voltage (Uin) Low: Uin < 5 V (off) High: Uin > 15 V (on) Max.: Uin = 32 V 10 www.krohne.com
Open the catalog to page 10nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn UFM 3030 Calculations are based on using spiral wound gaskets Nominal diameter Nominal pressure [inch] Standard material [lbs] Tube Design pressure (bar) Flange 20°C 140°C 180°C 220°C 18" 150 Carbon steel Carbon steel* 19,7 16,2 14,7 20" 150 Carbon steel Carbon steel* 19,7 16,2 14,7 * With carbon steel ASME flanges please note that minimum temperature is limited to -20°C (-4°F). For temperatures down to -25°C (-13°F) other materials are available on request. Design pressure ASME 300 lbs 1" 300 SS 316 L 316 L 51 45,4 44,4 43,1 1 1/4" 300 SS...
Open the catalog to page 13All KROHNE Messtechnik GmbH catalogs and technical brochures
-
LDM system Brochure en
28 Pages
-
Product Overview Brochure
84 Pages
-
OPTITEMP TRA/TCA PLUS
72 Pages
-
TIDALFLUX 2300 F
24 Pages
-
OPTISONIC 8300
40 Pages
-
OPTIBAR LC 1010
20 Pages
-
DWM1000/DWM2000
20 Pages
-
DW 181
28 Pages
-
OPTITEMP TRA-H6X/-C6X
36 Pages
-
Flow measurement
72 Pages
-
HYG.Accessories
24 Pages
-
IFC 050 Handbook
84 Pages
-
IFC 050
32 Pages
-
BATCHFLUX 5500 C
28 Pages
-
AFC 030 Converter
32 Pages
-
AMADAS Analyser Management
4 Pages
-
CALSYS for metering
4 Pages
-
Virtual flow computer
4 Pages
-
OPTIMASS 1000 Marine
2 Pages
-
Optimass 2000
2 Pages
-
OPTIMASS 6000 Marine
2 Pages
-
OPTIFLEX 4300 C Marine
2 Pages
-
OPTIWAVE 8300 C Marine
4 Pages
-
Accessories hygienic instruments
12 Pages
-
C95 CI
4 Pages
-
C95 Digital Panel Meter
4 Pages
-
OPTISONIC 6300 P | 6400
2 Pages
-
Inertisation (VA meters)
2 Pages
-
Unconventional Energy Resources
18 Pages
-
Temperature measurement
40 Pages
-
Brochure Food and Beverages
58 Pages
-
Product Overview
64 Pages
-
BM 500
16 Pages
-
H250 M40
48 Pages
-
OPTIFLUX 1000
24 Pages
-
IFC 100
36 Pages
-
H250 M40
20 Pages
-
SMARTPAT Overview
16 Pages
-
WATERFLUX 3070
24 Pages
-
Temperature Catalogue
148 Pages
-
Gas & Steam Product Overview
5 Pages
-
Pressure Product Overview
32 Pages
-
Water & Wastewater
44 Pages
-
Food Applications
100 Pages
-
OPTITEMP TT 51
2 Pages
-
OPTIWAVE 5200
2 Pages
-
OPTIWAVE 6300
2 Pages
-
ALTOSONIC V12 Highlights
18 Pages
-
Energy (Oil & Gas)
44 Pages
-
VISCOLINE
2 Pages
-
OPTISONIC 7300
2 Pages
-
OPTIFLEX 2200
2 Pages
-
BM 26
2 Pages
-
OPTISONIC 3400
16 Pages
-
OPTIMASS 6400
16 Pages
-
MICRO-SET
12 Pages
-
IFC 100 | IFC 300
9 Pages
-
ALTOSONIC V12
18 Pages
-
Brochure Oil & Gas Industry
40 Pages
-
Brochure Energy Measurement
28 Pages
-
Brochure Energy (Oil and Gas)
44 Pages
-
OPTITEMP TR | TC 100
28 Pages
-
IFC 300 Converter
56 Pages
-
DW 18 SERIES
28 Pages
-
Brochure Bioenergy
12 Pages
Archived catalogs
-
Level Product Overview
50 Pages
-
CARGOMASTER
16 Pages
-
SDA Flap-type Flowmeter
2 Pages
-
DWM 1000 | 2000
20 Pages
-
TR TC
28 Pages