.book Page 1 Tuesday, March 6, 2012 10:08 AM OPTITEMP TR/TC 100 Technical Datasheet Measuring inserts: TR 100 resistance thermometers and TC 100 thermocouples • Flexible, mineral insulated design • Fully universal • Spring loaded design © KROHNE 03/2012 - 4001019102 - TD OPTITEMP TR/TC 100 R02 en
Open the catalog to page 1PRODUCT FEATURES 1.1 Heavy-duty mineral insulated measuring inserts The OPTITEMP TR/TC 100 measuring inserts are intended for installation in thermometer assemblies and are made using mineral insulated mantle cable. They feature flexibility, superior insulation resistance and a high degree of vibration resistance. The TR 100 version contains a Pt 100 RTD with a characteristic curve according to DIN EN 60751. The TC 100 version features a thermocouple according to DIN EN 60584. Thermocouple measuring inserts come in type "K" or "J", other types are available on request. © Measuring insert...
Open the catalog to page 3• Power Supply • Pharmaceuticals and Food & Beverage Different process connections allow thermometer assemblies to be adapted for use in almost all industrial sectors: • Insertion-type thermometer • Threaded thermometer • Flange thermometer • Weld-in thermometer
Open the catalog to page 4PRODUCT FEATURES Variant with ceramic terminal block Fully sealed solder joints Available with 2, 3, 4, 6 or 8 connection terminals Washer disc with 2 screws, 2 springs and 2 locking Variant with flying wire ends Excepting the following points, the features correspond to those of the version with ceramic • Colour-coded, Teflon-insulated lead wires • Lead wires measuring 50 mm / 1.97" in length for the first measuring point • Lead wires measuring 100 mm / 3.94" in length for the second measuring point Variant with head-mounted transmitter The features correspond to those of the version with...
Open the catalog to page 5DPRODUCT FEATURES All three variants (with terminal block, with flying wire ends, with head-mounted transmitter] are available with the following sheath diameters and sensor types: Sheath diameter 3 mm / 0.12": Available with thin Mineral insulated mantle cable (material 1.4404] Magnesium oxide insulation (MgO] Sheath diameter 6 mm / 0.24": Available with thin Mineral insulated mantle cable (material 1.4404] Magnesium oxide insulation (MgO] Thermocouple measuring insert Available with sheath diameters of 3 mm / 0.12" Mineral insulated mantle cable (Inconel 600 ] Magnesium oxide insulation...
Open the catalog to page 6PRODUCT FEATURES All three variants (with terminal block, with flying wire ends, with head-mounted transmitter] are also available as intrinsically safe measuring inserts. The ATEX marking is: The intrinsically safe measuring inserts always have a sheath diameter of 6 mm / 0.24". The following options are available: • Sensor: 1 x Pt 100 RTD (wire-wound, ceramic) or 1 x thermocouple ("K" or "J"] • Tolerance class A (Pt 100) or 1 (thermocouple] The measuring insert with a resistance thermometer features a temperature-sensitive sensor made from a platinum RTD, whose value at 0 C / +32 F is 100...
Open the catalog to page 7DPRODUCT FEATURES The thermocouple features two electric conductors made from different metals, connected at one end. Each free end is connected to a compensation cable which is then connected to a millivolt meter. This circuitry forms a "thermal circuit". The point at which the two electric conductors connect is called the measuring point and the point at which the compensation cables connect to the conductors of the millivolt meter is called the cold junction. If the measuring point of this thermal circuit is heated up, a small electrical voltage (thermal voltage) can be measured. If,...
Open the catalog to page 82.1 Technical data tables The following data is provided for general applications. If you require data that is more relevant to your specific application, please contact us or your local representative. Additional information (certificates, special tools, software,...] and complete product documentation can be downloaded free of charge from the website (Download Center]. Measuring system Measuring accuracy
Open the catalog to page 9Operating conditions ATEX (pending]
Open the catalog to page 10The following data is provided for general applications. If you require data that is more relevant to your specific application, please contact us or your local representative. Additional information (certificates, special tools, software,...] and complete product documentation can be downloaded free of charge from the website (Download Center]. Measuring system Measuring accuracy Operating conditions ATEX (pending]
Open the catalog to page 112.2 Measuring ranges and tolerances 2.2.1 Measuring insert with Pt100 resistance thermometers Pt100: basic values and tolerances
Open the catalog to page 122.2.2 Measuring insert with type J thermocouples Type J: basic values and tolerances Figure 2-2: Type J tolerances
Open the catalog to page 13TECHNICAL DATA 2.2.3 Measuring insert with type K thermocouples Type K: basic values and tolerances Figure 2-3: Tolerances type K
Open the catalog to page 142.3 Permissible flow speed The maximum permissible flow speed forthe measuring insert depends on its immersion depth and on the density of the product. The greater the immersion depth and the higher the density, If the measuring insert is used in the thermowell, the flow speed is irrelevant. If, however, the flow goes against an unprotected measuring insert, its load must be calculated individually. If this isthe case, the manufacturer will offer further support. 2A Permissible operating pressure The maximum permissible load of the measuring inserts through the static operating pressure The...
Open the catalog to page 15The length of the connection wires is the same (40 mm / 1.58") for both variants (TR and TC 100). Different installation lengths are available on request
Open the catalog to page 16The operator himself bears the sole responsibility for the intended use of the measuring device regarding the suitability and the corrosion resistance of the used materials against the measured fluid. The manufacturer is not liable for any damage resulting from improper use or use for other than the intended purpose. Intended use is when the measuring insert is operated in a suitable thermometer assembly allowing for incorporation of replaceable measuring inserts. In every instance, the sheath length must be adapted to the thermowell. For more information about adjusting the thermowell and...
Open the catalog to page 17All KROHNE Messtechnik GmbH catalogs and technical brochures
-
LDM system Brochure en
28 Pages
-
Product Overview Brochure
84 Pages
-
OPTITEMP TRA/TCA PLUS
72 Pages
-
TIDALFLUX 2300 F
24 Pages
-
OPTISONIC 8300
40 Pages
-
OPTIBAR LC 1010
20 Pages
-
DWM1000/DWM2000
20 Pages
-
DW 181
28 Pages
-
OPTITEMP TRA-H6X/-C6X
36 Pages
-
Flow measurement
72 Pages
-
HYG.Accessories
24 Pages
-
IFC 050 Handbook
84 Pages
-
IFC 050
32 Pages
-
BATCHFLUX 5500 C
28 Pages
-
AFC 030 Converter
32 Pages
-
AMADAS Analyser Management
4 Pages
-
CALSYS for metering
4 Pages
-
Virtual flow computer
4 Pages
-
OPTIMASS 1000 Marine
2 Pages
-
Optimass 2000
2 Pages
-
OPTIMASS 6000 Marine
2 Pages
-
OPTIFLEX 4300 C Marine
2 Pages
-
OPTIWAVE 8300 C Marine
4 Pages
-
Accessories hygienic instruments
12 Pages
-
C95 CI
4 Pages
-
C95 Digital Panel Meter
4 Pages
-
OPTISONIC 6300 P | 6400
2 Pages
-
Inertisation (VA meters)
2 Pages
-
Unconventional Energy Resources
18 Pages
-
Temperature measurement
40 Pages
-
Brochure Food and Beverages
58 Pages
-
Product Overview
64 Pages
-
BM 500
16 Pages
-
H250 M40
48 Pages
-
OPTIFLUX 1000
24 Pages
-
IFC 100
36 Pages
-
H250 M40
20 Pages
-
SMARTPAT Overview
16 Pages
-
WATERFLUX 3070
24 Pages
-
Temperature Catalogue
148 Pages
-
Gas & Steam Product Overview
5 Pages
-
Pressure Product Overview
32 Pages
-
Water & Wastewater
44 Pages
-
Food Applications
100 Pages
-
OPTITEMP TT 51
2 Pages
-
OPTIWAVE 5200
2 Pages
-
OPTIWAVE 6300
2 Pages
-
ALTOSONIC V12 Highlights
18 Pages
-
Energy (Oil & Gas)
44 Pages
-
VISCOLINE
2 Pages
-
OPTISONIC 7300
2 Pages
-
OPTIFLEX 2200
2 Pages
-
BM 26
2 Pages
-
OPTISONIC 3400
16 Pages
-
OPTIMASS 6400
16 Pages
-
MICRO-SET
12 Pages
-
IFC 100 | IFC 300
9 Pages
-
ALTOSONIC V12
18 Pages
-
Brochure Oil & Gas Industry
40 Pages
-
Brochure Energy Measurement
28 Pages
-
Brochure Energy (Oil and Gas)
44 Pages
-
OPTITEMP TR | TC 100
28 Pages
-
IFC 300 Converter
56 Pages
-
DW 18 SERIES
28 Pages
-
Brochure Bioenergy
12 Pages
Archived catalogs
-
Level Product Overview
50 Pages
-
CARGOMASTER
16 Pages
-
SDA Flap-type Flowmeter
2 Pages
-
DWM 1000 | 2000
20 Pages
-
UFM 3030
16 Pages