Group: Krohne
Catalog excerpts
OPTITEMP TRA/TCA PLUS Technical Datasheet Industrial temperature assemblies with replaceable measuring inserts © KROHNE 06/2023 - 4002043602 TD OPTITEMP TRA/TCA R02 en
Open the catalog to page 1OPTITEMP TRA/TCA PLUS
Open the catalog to page 2OPTITEMP TRA/TCA PLUS 06/2023 - 4002043602 TD OPTITEMP TRA/TCA R02 en www.krohne.com 3
Open the catalog to page 3OPTITEMP TRA/TCA PLUS 1.1 Temperature assemblies for industrial applications Temperature assemblies for advanced requirements with replaceable measuring inserts can be used in various areas in industrial measuring technology. What sets them apart is the process connection and the thermowell version: multipart welded and one-piece bar stock. • Screw-in temperature assemblies without thermowells can be screwed into existing, welded on thermowells or into machine housings. The range includes DIN variants with M18 x 1.5 mm connection threads and ANSI variants with ½" NPT thread connections. •...
Open the catalog to page 4OPTITEMP TRA/TCA PLUS 06/2023 - 4002043602 TD OPTITEMP TRA/TCA R02 en www.krohne.com
Open the catalog to page 5OPTITEMP TRA/TCA PLUS nPRODUCT FEATURES1.2 Options and variants Selected versions of temperature assemblies and process connections The temperature assemblies shown here represent part of our range with the typical process adaptations: threaded, weld-in and flanged TRA-S50 / TCA-S50, screw-in temperature assembly without thermowell according to ANSI Process connections: • V2" NPT Material and diameter: • 1.4404: 0 SCH 40, 021.32 x 2.77 mm or 00.83x0.10" • Nipple-Union-Nipple variant, NUN • Nipple-Nipple variant, NN TRA-T30 / TCA-T30, weld temperature assembly with bar stock thermowell...
Open the catalog to page 6OPTITEMP TRA/TCA PLUS TRA-TF56 / TCA-TF56, flanged temperature assembly with bar stock thermowell according to ANSI PRODUCT FEATURESD TRA-TS54 / TCA-TS54, crew-in temperature assembly with bar stock thermowell according to ANSI Process connections: • V2" NPT, %" NPT • G V2, G % Materials and diameters: • 1.4571 / AISI 316 Ti: 016 and 22 mm or 00.62 and 0.86" • 1.4404 / AISI 316 L: 016 and 22 mm or 00.62 and 0.86" Process connections: • 150 lbs: 1", 1 V2" and 2" acc. ANSI, RF, RTJ 06/2023 - 4002043602 TD OPTITEMP TRA/TCA R02 en www.krohne.com 7
Open the catalog to page 7OPTITEMP TRA/TCA PLUS Thermowell tip designs Straight thermowell tip welded with TF32, TS33 and TS35 and bar stock for TS36, TS37, TS52, TF55 and TW58 Materials and diameters, raw material: • Material 1.4571 / 316 Ti: Ø 9 / 11 / 12 mm or Ø 0.35 / 0.43 / 0.47" • Material 1.4404 / 316 L: Ø 10 / 12 mm or Ø 0.39 / 0.47" Materials and diameters, bar stock: • Material 1.4571 / 316 Ti: Ø17 mm or Ø 0.66" • Material 1.4404 / 316 L: Ø16 / 17 / 19 and 23 mm or Ø0.62 / 0.66 / 0.74 / 0.90" Special features: • High load capacity Conical thermowell tip straight-conical for T30 and TF31 and conical for...
Open the catalog to page 8OPTITEMP TRA/TCA PLUS PRODUCT FEATURESD Measuring insert designs Variant with ceramic terminal block • Fully sealed solder joints • Pt100 connection in 2, 3 and 4-wire connection • Available with 2, 3, 4, 6 or 8 connection terminals • Sheath diameter: 6 + 0 - 0.1 mm • Washer disc with 2 screws, 2 springs and 2 retaining rings Variant with flying wire ends Excepting the following points, the features correspond to those of the version with ceramic terminals: • Colour-coded, Teflon-insulated lead wires • Lead wires measuring 50 mm / 1.97" in length for the first measuring point • Lead wires...
Open the catalog to page 9OPTITEMP TRA/TCA PLUS 1.3 Measuring principle All of the temperature assemblies described here belong to the class known as "contact temperature assemblies". Unlike "radiation temperature assemblies", these temperature assemblies come into direct contact with the medium whose temperature they are to measure. The type of measuring principle depends on the measuring insert sensor that you combine with the transmitter. Two different sensor types are available. Their respective measuring principles are described in the following subsections. 1.3.1 Resistance temperature sensor The measuring...
Open the catalog to page 10OPTITEMP TRA/TCA PLUS 1.3.2 Thermocouples The thermocouple features two electric conductors made from different metals, connected at one end. Each free end is connected to a compensation cable which is then connected to a millivolt meter. This circuitry forms a "thermal circuit". The point at which the two electric conductors connect is called the measuring point and the point at which the compensation cables connect to the conductors of the millivolt meter is called the cold junction. If the measuring point of this thermal circuit is heated up, a small electrical voltage (thermal voltage)...
Open the catalog to page 11OPTITEMP TRA/TCA PLUS 2 TECHNICAL DATA 2.1 Technical data tables • The following data is provided for general applications, if you require data that is more relevant to your specific application, please contact us or your local sales office. • Additional information (certificates, special tools, software,...] and complete product documentation can be downloaded free of charge from the website (Downloadcenter). 12 www.krohne.com 06/2023 - 4002043602 TD OPTITEMP TRA/TCA R02 en
Open the catalog to page 12OPTITEMP TRA/TCA PLUS TECHNICAL DATA 2 Measuring accuracy 06/2023 - 4002043602 TD OPTITEMP TRA/TCA R02 en www.krohne.com 13
Open the catalog to page 13OPTITEMP TRA/TCA PLUS 2 TECHNICAL DATA Materials Weld temperature assembly with Attached using welded sleeves; direct welding is possible starting at extension tube a wall thickness of 20 mm / 0.79". 14 www.krohne.com 06/2023 - 4002043602 TD OPTITEMP TRA/TCA R02 en
Open the catalog to page 14OPTITEMP TRA/TCA PLUS TECHNICAL DATA 2Electrical connections Power supply 06/2023 - 4002043602 TD OPTITEMP TRA/TCA R02 en www.krohne.com 15
Open the catalog to page 15OPTITEMP TRA/TCA PLUS 2 TECHNICAL DATA2.2 Dimensions2.2.1 Cable entry threads Figure 2-1: Cable gland Table 2-1: Dimensions in mm and inch For connection heads with 1/2 NPT threads, there are process connections and cable glands in 1/2 NPT thread versions. Connection heads with 1/2 NPT threads are supplied without cable gland. There are no plans for a combination of M24 x1.5 mm and 1/2 NPT thread. 16 www.krohne.com 06/2023 - 4002043602 TD OPTITEMP TRA/TCA R02 en
Open the catalog to page 16All KROHNE Messtechnik GmbH catalogs and technical brochures
-
LDM system Brochure en
28 Pages
-
Product Overview Brochure
84 Pages
-
TIDALFLUX 2300 F
24 Pages
-
OPTISONIC 8300
40 Pages
-
OPTIBAR LC 1010
20 Pages
-
DWM1000/DWM2000
20 Pages
-
DW 181
28 Pages
-
OPTITEMP TRA-H6X/-C6X
36 Pages
-
Flow measurement
72 Pages
-
HYG.Accessories
24 Pages
-
IFC 050 Handbook
84 Pages
-
IFC 050
32 Pages
-
BATCHFLUX 5500 C
28 Pages
-
AFC 030 Converter
32 Pages
-
AMADAS Analyser Management
4 Pages
-
CALSYS for metering
4 Pages
-
Virtual flow computer
4 Pages
-
OPTIMASS 1000 Marine
2 Pages
-
Optimass 2000
2 Pages
-
OPTIMASS 6000 Marine
2 Pages
-
OPTIFLEX 4300 C Marine
2 Pages
-
OPTIWAVE 8300 C Marine
4 Pages
-
Accessories hygienic instruments
12 Pages
-
C95 CI
4 Pages
-
C95 Digital Panel Meter
4 Pages
-
OPTISONIC 6300 P | 6400
2 Pages
-
Inertisation (VA meters)
2 Pages
-
Unconventional Energy Resources
18 Pages
-
Temperature measurement
40 Pages
-
Brochure Food and Beverages
58 Pages
-
Product Overview
64 Pages
-
BM 500
16 Pages
-
H250 M40
48 Pages
-
OPTIFLUX 1000
24 Pages
-
IFC 100
36 Pages
-
H250 M40
20 Pages
-
SMARTPAT Overview
16 Pages
-
WATERFLUX 3070
24 Pages
-
Temperature Catalogue
148 Pages
-
Gas & Steam Product Overview
5 Pages
-
Pressure Product Overview
32 Pages
-
Water & Wastewater
44 Pages
-
Food Applications
100 Pages
-
OPTITEMP TT 51
2 Pages
-
OPTIWAVE 5200
2 Pages
-
OPTIWAVE 6300
2 Pages
-
ALTOSONIC V12 Highlights
18 Pages
-
Energy (Oil & Gas)
44 Pages
-
VISCOLINE
2 Pages
-
OPTISONIC 7300
2 Pages
-
OPTIFLEX 2200
2 Pages
-
BM 26
2 Pages
-
OPTISONIC 3400
16 Pages
-
OPTIMASS 6400
16 Pages
-
MICRO-SET
12 Pages
-
IFC 100 | IFC 300
9 Pages
-
ALTOSONIC V12
18 Pages
-
Brochure Oil & Gas Industry
40 Pages
-
Brochure Energy Measurement
28 Pages
-
Brochure Energy (Oil and Gas)
44 Pages
-
OPTITEMP TR | TC 100
28 Pages
-
IFC 300 Converter
56 Pages
-
DW 18 SERIES
28 Pages
-
Brochure Bioenergy
12 Pages
Archived catalogs
-
Level Product Overview
50 Pages
-
CARGOMASTER
16 Pages
-
SDA Flap-type Flowmeter
2 Pages
-
DWM 1000 | 2000
20 Pages
-
UFM 3030
16 Pages
-
TR TC
28 Pages