OPTITEMP TRA/TCA PLUS Technical Datasheet Industrial temperature assemblies with replaceable measuring inserts © KROHNE 06/2023 - 4002043602 TD OPTITEMP TRA/TCA R02 en

Open the catalog to page 1
OPTITEMP TRA/TCA PLUS - 2

OPTITEMP TRA/TCA PLUS

Open the catalog to page 2
OPTITEMP TRA/TCA PLUS - 3

OPTITEMP TRA/TCA PLUS 06/2023 - 4002043602 TD OPTITEMP TRA/TCA R02 en www.krohne.com 3

Open the catalog to page 3
OPTITEMP TRA/TCA PLUS - 4

OPTITEMP TRA/TCA PLUS 1.1 Temperature assemblies for industrial applications Temperature assemblies for advanced requirements with replaceable measuring inserts can be used in various areas in industrial measuring technology. What sets them apart is the process connection and the thermowell version: multipart welded and one-piece bar stock. • Screw-in temperature assemblies without thermowells can be screwed into existing, welded on thermowells or into machine housings. The range includes DIN variants with M18 x 1.5 mm connection threads and ANSI variants with ½" NPT thread connections. •...

Open the catalog to page 4
OPTITEMP TRA/TCA PLUS - 5

OPTITEMP TRA/TCA PLUS 06/2023 - 4002043602 TD OPTITEMP TRA/TCA R02 en www.krohne.com

Open the catalog to page 5
OPTITEMP TRA/TCA PLUS - 6

OPTITEMP TRA/TCA PLUS nPRODUCT FEATURES1.2 Options and variants Selected versions of temperature assemblies and process connections The temperature assemblies shown here represent part of our range with the typical process adaptations: threaded, weld-in and flanged TRA-S50 / TCA-S50, screw-in temperature assembly without thermowell according to ANSI Process connections: • V2" NPT Material and diameter: • 1.4404: 0 SCH 40, 021.32 x 2.77 mm or 00.83x0.10" • Nipple-Union-Nipple variant, NUN • Nipple-Nipple variant, NN TRA-T30 / TCA-T30, weld temperature assembly with bar stock thermowell...

Open the catalog to page 6
OPTITEMP TRA/TCA PLUS - 7

OPTITEMP TRA/TCA PLUS TRA-TF56 / TCA-TF56, flanged temperature assembly with bar stock thermowell according to ANSI PRODUCT FEATURESD TRA-TS54 / TCA-TS54, crew-in temperature assembly with bar stock thermowell according to ANSI Process connections: • V2" NPT, %" NPT • G V2, G % Materials and diameters: • 1.4571 / AISI 316 Ti: 016 and 22 mm or 00.62 and 0.86" • 1.4404 / AISI 316 L: 016 and 22 mm or 00.62 and 0.86" Process connections: • 150 lbs: 1", 1 V2" and 2" acc. ANSI, RF, RTJ 06/2023 - 4002043602 TD OPTITEMP TRA/TCA R02 en www.krohne.com 7

Open the catalog to page 7
OPTITEMP TRA/TCA PLUS - 8

OPTITEMP TRA/TCA PLUS Thermowell tip designs Straight thermowell tip welded with TF32, TS33 and TS35 and bar stock for TS36, TS37, TS52, TF55 and TW58 Materials and diameters, raw material: • Material 1.4571 / 316 Ti: Ø 9 / 11 / 12 mm or Ø 0.35 / 0.43 / 0.47" • Material 1.4404 / 316 L: Ø 10 / 12 mm or Ø 0.39 / 0.47" Materials and diameters, bar stock: • Material 1.4571 / 316 Ti: Ø17 mm or Ø 0.66" • Material 1.4404 / 316 L: Ø16 / 17 / 19 and 23 mm or Ø0.62 / 0.66 / 0.74 / 0.90" Special features: • High load capacity Conical thermowell tip straight-conical for T30 and TF31 and conical for...

Open the catalog to page 8
OPTITEMP TRA/TCA PLUS - 9

OPTITEMP TRA/TCA PLUS PRODUCT FEATURESD Measuring insert designs Variant with ceramic terminal block • Fully sealed solder joints • Pt100 connection in 2, 3 and 4-wire connection • Available with 2, 3, 4, 6 or 8 connection terminals • Sheath diameter: 6 + 0 - 0.1 mm • Washer disc with 2 screws, 2 springs and 2 retaining rings Variant with flying wire ends Excepting the following points, the features correspond to those of the version with ceramic terminals: • Colour-coded, Teflon-insulated lead wires • Lead wires measuring 50 mm / 1.97" in length for the first measuring point • Lead wires...

Open the catalog to page 9
OPTITEMP TRA/TCA PLUS - 10

OPTITEMP TRA/TCA PLUS 1.3 Measuring principle All of the temperature assemblies described here belong to the class known as "contact temperature assemblies". Unlike "radiation temperature assemblies", these temperature assemblies come into direct contact with the medium whose temperature they are to measure. The type of measuring principle depends on the measuring insert sensor that you combine with the transmitter. Two different sensor types are available. Their respective measuring principles are described in the following subsections. 1.3.1 Resistance temperature sensor The measuring...

Open the catalog to page 10
OPTITEMP TRA/TCA PLUS - 11

OPTITEMP TRA/TCA PLUS 1.3.2 Thermocouples The thermocouple features two electric conductors made from different metals, connected at one end. Each free end is connected to a compensation cable which is then connected to a millivolt meter. This circuitry forms a "thermal circuit". The point at which the two electric conductors connect is called the measuring point and the point at which the compensation cables connect to the conductors of the millivolt meter is called the cold junction. If the measuring point of this thermal circuit is heated up, a small electrical voltage (thermal voltage)...

Open the catalog to page 11
OPTITEMP TRA/TCA PLUS - 12

OPTITEMP TRA/TCA PLUS 2 TECHNICAL DATA 2.1 Technical data tables • The following data is provided for general applications, if you require data that is more relevant to your specific application, please contact us or your local sales office. • Additional information (certificates, special tools, software,...] and complete product documentation can be downloaded free of charge from the website (Downloadcenter). 12 www.krohne.com 06/2023 - 4002043602 TD OPTITEMP TRA/TCA R02 en

Open the catalog to page 12
OPTITEMP TRA/TCA PLUS - 13

OPTITEMP TRA/TCA PLUS TECHNICAL DATA 2 Measuring accuracy 06/2023 - 4002043602 TD OPTITEMP TRA/TCA R02 en www.krohne.com 13

Open the catalog to page 13
OPTITEMP TRA/TCA PLUS - 14

OPTITEMP TRA/TCA PLUS 2 TECHNICAL DATA Materials Weld temperature assembly with Attached using welded sleeves; direct welding is possible starting at extension tube a wall thickness of 20 mm / 0.79". 14 www.krohne.com 06/2023 - 4002043602 TD OPTITEMP TRA/TCA R02 en

Open the catalog to page 14
OPTITEMP TRA/TCA PLUS - 15

OPTITEMP TRA/TCA PLUS TECHNICAL DATA 2Electrical connections Power supply 06/2023 - 4002043602 TD OPTITEMP TRA/TCA R02 en www.krohne.com 15

Open the catalog to page 15
OPTITEMP TRA/TCA PLUS - 16

OPTITEMP TRA/TCA PLUS 2 TECHNICAL DATA2.2 Dimensions2.2.1 Cable entry threads Figure 2-1: Cable gland Table 2-1: Dimensions in mm and inch For connection heads with 1/2 NPT threads, there are process connections and cable glands in 1/2 NPT thread versions. Connection heads with 1/2 NPT threads are supplied without cable gland. There are no plans for a combination of M24 x1.5 mm and 1/2 NPT thread. 16 www.krohne.com 06/2023 - 4002043602 TD OPTITEMP TRA/TCA R02 en

Open the catalog to page 16

All KROHNE Messtechnik GmbH catalogs and technical brochures

  1. OPTISONIC 8300

    40 Pages

  2. DW 181

    28 Pages

  3. IFC 050

    32 Pages

  4. C95 CI

    4 Pages

  5. BM 500

    16 Pages

  6. H250 M40

    48 Pages

  7. OPTIFLUX 1000

    24 Pages

  8. IFC 100

    36 Pages

  9. H250 M40

    20 Pages

  10. WATERFLUX 3070

    24 Pages

  11. VISCOLINE

    2 Pages

  12. BM 26

    2 Pages

  13. OPTISONIC 3400

    16 Pages

  14. OPTIMASS 6400

    16 Pages

  15. MICRO-SET

    12 Pages

  16. ALTOSONIC V12

    18 Pages

  17. DW 18 SERIES

    28 Pages

Archived catalogs

  1. CARGOMASTER

    16 Pages

  2. UFM 3030

    16 Pages

  3. TR TC

    28 Pages