KROHNE► achieve more ► Enhanced repeatability in excess of API Chapter 4, for greater control on metering accuracy ► Quick change-out and no need to re-calibrate your prover ► One model fits all prover pipes from 3 - 36 inches ► Stainless steel wetted parts make the Micro-set suitable for most products
Open the catalog to page 1Micro-setProver Sphere DetectorNo matter how precisely you engineer your prover - and very few in the world can reach our quality - it's the sphere detection that determines the accuracy.Micro-set has all the features you need: ► Proven accuracy & reliability ► Repeatable for the lifetime of the detector ► Robust, durable and hard-wearing ► In service all around the world for over 25 years.
Open the catalog to page 2innovative Concept Micro-set Prover Sphere Detector Micro-set meter prover sphere detectors have shown themselves repeatable and reliable on NGL, butane, propane, rened petroleum products and crude oil. The detectors have performed well on hot, heavy, waxy crude oil and special ushing ports can be incorporated to enable cleaning during shut-down in extreme circumstances. Retrot model for replacing other types of detector KROHNE can manufacture special Micro-set sphere detectors to suit your application. Given detailed dimensional information regarding your existing sphere detector boss KROHNE...
Open the catalog to page 3advanced Performance Designed to perform beyond existing limitations Technical description The Micro-set meter prover sphere detector was originally designed and developed to satisfy a requirement for a 3” ball prover for butane and propane, a requirement which no existing proprietary unit could meet at the time. The Micro-set sphere detector is a mechanically activated position sensor for signalling the passage of a meter prover sphere. The unit is bolted to the prover loop pipe by means of a mounting boss, this allows the Micro-set plunger to protrude through the pipe wall and the prover sphere...
Open the catalog to page 4Proven to work betterCalibration tests Any Micro-set sphere detector that is set correctly using the same setting fixture can be exchanged in a pipe prover without significantly changing the base volume. Calibration tests undertaken by SGS, the international calibration specialists, on a four detector 10" prover loop produced the following results. The total spread of results from the four tests was only 0.0068%.
Open the catalog to page 5useful Options Proven options ensure reliable results under all circumstances The vast majority of detectors supplied are of standard design however there are two optional design enhancements that may be incorporated into both the ANSI 600 and ANSI 1500 models where application conditions are particularly onerous. In situ cleaning/ushing option Where the owing product is a crude oil with a high wax and/or sediment content there is the possibility that the build up of surface deposits within the detector body may prevent proper operation of the detector. Typically the movement of the plunger may...
Open the catalog to page 6better Performance Modernise your existing prover Retrots The Micro-set may be mounted on an existing prover which has been tted with mounting bosses for other detector types. To achieve this, the Micro-set may be supplied with an extended plunger and modied body to aid the direct replacement of the existing detector type. Alternatively the Micro-set can be tted with an extended plunger and an adaptor. Micro-set can be easily tted on site anywhere in th
Open the catalog to page 7Hazardous Area Approval ATEX Approval The Micro-set Sphere Detector is certified EExd IIB T6 and is suitable for use in hazardous areas. This certificate and its schedules may only be reproduced in its entirety and without change. Sira Certification Service Rake Lane, Eccleston, Chester, CH4 9JN, England Tel: +44 ( 0) 1244 670900 Equipment intended for use in Potentially Explosive Atmospheres Directive 94/9/EC Certificate Number: Sira 03ATEX1127X Issue: 2 Equipment: MSDI Micro-Set Sphere Detector Address: 70 Carwood Road Sheffield South Yorkshire S4 7SD UK This equipment and any acceptable variation...
Open the catalog to page 8including all wearing, non-wearing and consumable items
Open the catalog to page 9Pipe diameter Pressure rating ANSI 600# &1500# (higher available on request) Element type Encapsulated reed switch Switch rating Power supply Process connection Mounting boss Plunger hole diameter 20 or 32mm depending on pipe wall thickness Vertical displacement resolution Design pressure Design temperature (process) Design temperature (ambient) Housing: 316 stainless steel Wetted parts: 316 stainless steel O-rings: Viton Electric. Classification Cable entry (to junction box) Hazardous area classification ATEX II2G, EEx‘d‘ IIB T6 ATEX Certificate No: Sira 03ATEX1127X Issue 2 SIRA Certificate - SIRA...
Open the catalog to page 10Setting, Installation, operating and maintenance manual General arrangement drawing (included in above SIOM manual) Certificate of conformity ATEX hazardous area certificate Detector functional test reports, including pressure tests Optional Documentation NACE certification (must be stated at time of order) Junction box hazardous area certificate Junction box IP rating certificate Junction box installation instructions Mounting boss material certificate Options Weld-on pipe-mounting boss Flushing port Retrofit to existing fittings Spare parts kit Junction box PEEK bushes for dry, low lubricity LNG /...
Open the catalog to page 11Flow Meters for Custody Transfer Liquid Flow Metering Systems Gas Flow Metering Systems Wet Gas Metering Systems Provers & Master Meters Flow Computing, Supervisory Software & Analyzer Management Calibration Systems Tank Inventory & Management Systems Analyzer Houses and Shelters Loading & Off-loading Systems Leak Detection and Localisation Systems Revamps & Upgrades Testing, Installation, Commissioning, Service Training Gas Ultrasonic Flow Meters for Custody Transfer Liquid Ultrasonic Flow Meters for Custody Transfer Mass Flow Meters for Custody Transfer Venturis for Wet Gas Metering Prover...