Group: Krohne
Catalog excerpts
.backup.book Page 1 Thursday, September 9, 2010 1:21 PM IFC 300 Technical Datasheet Signal converter for electromagnetic flowmeters • Diagnostics: Process and device diagnostics, accuracy check • One signal converter for all applications • Exceeds requirements of VDI / VDE 2650 and NAMUR NE 107 The documentation is only complete when used in combination with the relevant documentation for the sensor. © KROHNE 09/2010 - 4000295603 - TD IFC 300 R06 en
Open the catalog to page 1Product features .backup.book Page 4 Thursday, September 9, 2010 1:21 PM 1 PRODUCT FEATURES IFC 300 1.1 The signal converter with the highest performance The electromagnetic signal converter IFC 300 is designed to measure the flow velocity, conductivity, volume and mass flow of electrically conductive liquid media. The signal converter can be combined with any measuring sensor, making it very widely used. In terms of available housing versions, there is a compact variant, in which the signal converter is connected to the measuring sensor, as well as the field, wall-mounted and 19"...
Open the catalog to page 4.backup.book Page 5 Thursday, September 9, 2010 1:21 PM PRODUCT FEATURES 1 IFC 300 Highlights • High measuring accuracy and long-term stability : ±0.15% of measured value ± 1 mm/s • Optimal zero point stability independent from product properties • Superior process reliability thanks to standard integrated diagnostics: testing of device functions, check for compliance with specifications and application testing • Available inputs and outputs: Current output (incl. HART®), pulse/frequency output, status output, control input and current input • Suitable for both partially filled and fully...
Open the catalog to page 5.backup.book Page 6 Thursday, September 9, 2010 1:21 PM 1 PRODUCT FEATURES IFC 300 1.2 Options and variants Modular converter concept The electromagnetic signal converter IFC 300 comes in different variants and gives the highest performance for all applications you can think of. From networking in the water & wastewater industry to blending in the chemical industry, from batching in the food & beverage industry to transport in the paper & pulp industry. And not to forget all of the other applications where the flow of electrically conductive liquids is to be measured. The different versions...
Open the catalog to page 6.backup.book Page 7 Thursday, September 9, 2010 1:21 PM PRODUCT FEATURES 1 IFC 300 Remote design in various versions The signal converter in the wall-mounted housing is generally used when it is difficult to access the measuring point or when ambient conditions do not allow the use of the compact version. (signal converter in wall-mounted housing) The signal converter in the 19" rack-mounted housing is typically built into the central control room, away from the harsh ambient conditions that can be present at the measuring point. (signal converter in 19" rack-mounted housing (28 TE))...
Open the catalog to page 7.backup.book Page 8 Thursday, September 9, 2010 1:21 PM 1 PRODUCT FEATURES IFC 300 Diagnostics A part of the standard functionality is the comprehensive diagnosis, which consists of three different testing series. Testing the device function Checking the microcontroller, memory and outputs. Out-of-spec diagnosis Online and cyclical verification to determine whether the measuring device is still within its specifications regarding accuracy and linearity. Application testing The detection of potential problems such as gas bubbles, electrode deposits, low conductivity, liner damage, faulty...
Open the catalog to page 8.backup.book Page 9 Thursday, September 9, 2010 1:21 PM PRODUCT FEATURES 1 IFC 300 1.4 Measuring principle An electrically conductive fluid flows inside an electrically insulated pipe through a magnetic field. This magnetic field is generated by a current, flowing through a pair of field coils. Inside of the fluid, a voltage U is generated: U=v*k*B*D in which: v = mean flow velocity k = factor correcting for geometry B = magnetic field strength D = inner diameter of flow meter The signal voltage U is picked off by electrodes and is proportional to the mean flow velocity v and thus the flow...
Open the catalog to page 9Technical data .backup.book Page 10 Thursday, September 9, 2010 1:21 PM 2 TECHNICAL DATA IFC 300 2.1 Technical data • The following data is provided for general applications. If you require data that is more relevant to your specific application, please contact us or your local representative. • Additional information (certificates, special tools, software,...) and complete product documentation can be downloaded free of charge from the website (Download Center). Measuring system Measuring principle Faraday's law of induction Application range Continuous measurement of current volume flow,...
Open the catalog to page 10.backup.book Page 11 Thursday, September 9, 2010 1:21 PM TECHNICAL DATA 2 IFC 300 Options Outputs / inputs Current (incl. HART®), pulse, frequency and/or status output, limit switch and/or control input or current input (depending on the I/O version) Totalizer 2 (optional 3) internal counters with a max. of 8 counter places (e.g. for counting volume and/or mass units) Verification Integrated verification, diagnostic functions: measuring device, process, measured value, empty pipe detection, stabilization Communication interfaces Foundation Fieldbus, Profibus PA and DP, Modbus, HART® Display...
Open the catalog to page 11.backup.book Page 12 Thursday, September 9, 2010 1:21 PM 2 TECHNICAL DATA IFC 300 Operating conditions Temperature Process temperature Refer to technical data for the measuring sensor. Ambient temperature Depending on the version and combination of outputs. It is a good idea to protect the converter from external heat sources such as direct sunlight as higher temperatures reduce the life cycle of all electronic components. -40…+65°C / -40…+149°F Ambient temperatures below -25°C / -13°F, may affect the readability of the display. Storage temperature -50…+70°C / -58…+158°F Pressure Medium...
Open the catalog to page 12.backup.book Page 13 Thursday, September 9, 2010 1:21 PM TECHNICAL DATA 2 IFC 300 Materials Signal converter housing Standard Version C and F: die-cast aluminium (polyurethane coated) Version W: polyamide - polycarbonate Version R (28 TE): Aluminium, stainless steel and aluminium sheet, partially polyester-coated Version R (21 TE): Aluminium and aluminium sheet, partially polyester-coated Option Versions C and F: Stainless steel 316 L (1.4408) Measuring sensor For housing materials, process connections, liners, grounding electrodes and gaskets, refer to technical data for the measuring...
Open the catalog to page 13All KROHNE Messtechnik GmbH catalogs and technical brochures
-
LDM system Brochure en
28 Pages
-
Product Overview Brochure
84 Pages
-
OPTITEMP TRA/TCA PLUS
72 Pages
-
TIDALFLUX 2300 F
24 Pages
-
OPTISONIC 8300
40 Pages
-
OPTIBAR LC 1010
20 Pages
-
DWM1000/DWM2000
20 Pages
-
DW 181
28 Pages
-
OPTITEMP TRA-H6X/-C6X
36 Pages
-
Flow measurement
72 Pages
-
HYG.Accessories
24 Pages
-
IFC 050 Handbook
84 Pages
-
IFC 050
32 Pages
-
BATCHFLUX 5500 C
28 Pages
-
AFC 030 Converter
32 Pages
-
AMADAS Analyser Management
4 Pages
-
CALSYS for metering
4 Pages
-
Virtual flow computer
4 Pages
-
OPTIMASS 1000 Marine
2 Pages
-
Optimass 2000
2 Pages
-
OPTIMASS 6000 Marine
2 Pages
-
OPTIFLEX 4300 C Marine
2 Pages
-
OPTIWAVE 8300 C Marine
4 Pages
-
Accessories hygienic instruments
12 Pages
-
C95 CI
4 Pages
-
C95 Digital Panel Meter
4 Pages
-
OPTISONIC 6300 P | 6400
2 Pages
-
Inertisation (VA meters)
2 Pages
-
Unconventional Energy Resources
18 Pages
-
Temperature measurement
40 Pages
-
Brochure Food and Beverages
58 Pages
-
Product Overview
64 Pages
-
BM 500
16 Pages
-
H250 M40
48 Pages
-
OPTIFLUX 1000
24 Pages
-
IFC 100
36 Pages
-
H250 M40
20 Pages
-
SMARTPAT Overview
16 Pages
-
WATERFLUX 3070
24 Pages
-
Temperature Catalogue
148 Pages
-
Gas & Steam Product Overview
5 Pages
-
Pressure Product Overview
32 Pages
-
Water & Wastewater
44 Pages
-
Food Applications
100 Pages
-
OPTITEMP TT 51
2 Pages
-
OPTIWAVE 5200
2 Pages
-
OPTIWAVE 6300
2 Pages
-
ALTOSONIC V12 Highlights
18 Pages
-
Energy (Oil & Gas)
44 Pages
-
VISCOLINE
2 Pages
-
OPTISONIC 7300
2 Pages
-
OPTIFLEX 2200
2 Pages
-
BM 26
2 Pages
-
OPTISONIC 3400
16 Pages
-
OPTIMASS 6400
16 Pages
-
MICRO-SET
12 Pages
-
IFC 100 | IFC 300
9 Pages
-
ALTOSONIC V12
18 Pages
-
Brochure Oil & Gas Industry
40 Pages
-
Brochure Energy Measurement
28 Pages
-
Brochure Energy (Oil and Gas)
44 Pages
-
OPTITEMP TR | TC 100
28 Pages
-
DW 18 SERIES
28 Pages
-
Brochure Bioenergy
12 Pages
Archived catalogs
-
Level Product Overview
50 Pages
-
CARGOMASTER
16 Pages
-
SDA Flap-type Flowmeter
2 Pages
-
DWM 1000 | 2000
20 Pages
-
UFM 3030
16 Pages
-
TR TC
28 Pages