Group: Krohne
Catalog excerpts
Signal converter for electromagnetic flowmeters Electronic revision: ER 3.0.3_ The documentation is only complete when used in combination with the relevant documentation for the flow sensor.
Open the catalog to page 1AH rights reserved. It is prohibited to reproduce this documentation, or any part thereof, without the prior written authorisation of KROHNE Messtechnik GmbH. Subject to change without notice. Copyright 2016 by KROHNE Messtechnik GmbH - Ludwig-Krohne-Str. 5 - 47058 Duisburg (Germany)
Open the catalog to page 2D SAFETY INSTRUCTIONS 1.1 Software history The "Electronic Revision" (ER) is consulted to document the revision status of electronic equipment according to NE 53 for all GDC devices. It is easy to see from the ER whether troubleshooting or larger changes in the electronic equipment have taken place and how that has affected the compatibility.
Open the catalog to page 6SAFETY INSTRUCTIONS D 1.2 Intended use The electromagnetic flowmeters are designed exclusively to measure the flow and conductivity of electrically conductive, liquid media. WARNING! If the device is not used according to the operating conditions (refer to chapter "Technical data"], the intended protection could be affected. INFORMA T/ON! This device is a Group 1, Class A device as specified within CISPR11:2009. It is intended for use in industrial environment. There may be potential difficulties in ensuring electromagnetic compatibility in other environments, due to conducted as well as...
Open the catalog to page 71.4 Safety instructions from the manufacturer 1.4.1 Copyright and data protection The contents of this document have been created with great care. Nevertheless, we provide no guarantee that the contents are correct, complete or up-to-date. The contents and works in this document are subject to copyright. Contributions from third parties are identified as such. Reproduction, processing, dissemination and any type of use beyond what is permitted under copyright requires written authorisation from the respective author and/or the manufacturer. The manufacturer tries always to observe the...
Open the catalog to page 81.4.3 Product liability and warranty The operator shall bear responsibility for the suitability of the device for the specific purpose. The manufacturer accepts no liability for the consequences of misuse by the operator. Improper installation or operation of the devices (systems) will cause the warranty to be void. The respective "Standard Terms and Conditions" which form the basis for the sales contract shall also apply. 1.4.4 Information concerning the documentation To prevent any injury to the user or damage to the device it is essential that you read the information in this document...
Open the catalog to page 91.4.5 Warnings and symbols used Safety warnings are indicated by the following symbols. DANGER! This warning refers to the immediate danger when working with electricity. DANGER! This warning refers to the immediate danger of burns caused by heat or hot surfaces. DANGER! This warning refers to the immediate danger when using this device in a hazardous atmosphere. DANGER! These warnings must be observed without fail. Even partial disregard of this warning can lead to serious health problems and even death. There is also the risk of seriously damaging the device or parts of the operator's...
Open the catalog to page 102.1 Scope of delivery INFORMATION! Inspect the packaging carefully for damages or signs of rough handling. Report damage to the carrier and to the local office of the manufacturer. INFORMATION! Do a check of the packing list to make sure that you have all the elements given in the order. INFORMATION! Look at the device nameplate to ensure that the device is delivered according to your order. Check for the correct supply voltage printed on the nameplate. Figure 2-1: Scope of delivery 1 Device in the version as ordered 2 Bar pencil (to operate the signal converter when the housing is closed)...
Open the catalog to page 112 DEVICE DESCRIPTION 2.2 Device description Electromagnetic flowmeters are designed exclusively to measure the flow and conductivity of electrically conductive, liquid media. Your measuring device is supplied ready for operation. The factory settings for the operating data have been made in accordance with your order specifications. The following versions are available: • Compact version (the signal converter is mounted directly on the flow sensor) • Remote version (electrical connection to the flow sensor via field current and signal cable) Flow sensor
Open the catalog to page 12DEVICE DESCRIPTION 22.4 Nameplates INFORMA T/ON! Look at the device nameplate to ensure that the device is delivered according to your order. Check for the correct supply voltage printed on the nameplate. /- KRDHNE Altometer, Dordrecht Figure 2-3: Example of a nameplate ® Manufacturer 2 Power supply data 3 Electronic version (ER) @ Maximum working pressure © GK/GKL values (flow sensor constants); size (mm/inch); field frequency; protection category; materials of wetted parts 6 Product designation, serial number and manufacturing date
Open the catalog to page 133.1 General notes on installation INFORMATION! Inspect the packaging carefully for damages or signs of rough handling. Report damage to the carrier and to the local office of the manufacturer. INFORMATION! Do a check of the packing list to make sure that you have all the elements given in the order. INFORMATION! Look at the device nameplate to ensure that the device is delivered according to your order. Check for the correct supply voltage printed on the nameplate. Store the device in a dry, dust-free location. Avoid continuous direct sunlight. Store the device in its original packing....
Open the catalog to page 143.6 Mounting of the wall housing, remote version INFORMATION! Assembly materials and tools are not part of the delivery. Use the assembly materials and tools in compliance with the applicable occupational health and safety directives. Figure 3-1: Mounting of the wall housing 1 Prepare the holes with the aid of the mounting plate. For further information refer to Mounting plate, wall version on page 79. 2 Fasten the device securely to the wall with the mounting plate.
Open the catalog to page 15All KROHNE Messtechnik GmbH catalogs and technical brochures
-
LDM system Brochure en
28 Pages
-
Product Overview Brochure
84 Pages
-
OPTITEMP TRA/TCA PLUS
72 Pages
-
TIDALFLUX 2300 F
24 Pages
-
OPTISONIC 8300
40 Pages
-
OPTIBAR LC 1010
20 Pages
-
DWM1000/DWM2000
20 Pages
-
DW 181
28 Pages
-
OPTITEMP TRA-H6X/-C6X
36 Pages
-
Flow measurement
72 Pages
-
HYG.Accessories
24 Pages
-
IFC 050
32 Pages
-
BATCHFLUX 5500 C
28 Pages
-
AFC 030 Converter
32 Pages
-
AMADAS Analyser Management
4 Pages
-
CALSYS for metering
4 Pages
-
Virtual flow computer
4 Pages
-
OPTIMASS 1000 Marine
2 Pages
-
Optimass 2000
2 Pages
-
OPTIMASS 6000 Marine
2 Pages
-
OPTIFLEX 4300 C Marine
2 Pages
-
OPTIWAVE 8300 C Marine
4 Pages
-
Accessories hygienic instruments
12 Pages
-
C95 CI
4 Pages
-
C95 Digital Panel Meter
4 Pages
-
OPTISONIC 6300 P | 6400
2 Pages
-
Inertisation (VA meters)
2 Pages
-
Unconventional Energy Resources
18 Pages
-
Temperature measurement
40 Pages
-
Brochure Food and Beverages
58 Pages
-
Product Overview
64 Pages
-
BM 500
16 Pages
-
H250 M40
48 Pages
-
OPTIFLUX 1000
24 Pages
-
IFC 100
36 Pages
-
H250 M40
20 Pages
-
SMARTPAT Overview
16 Pages
-
WATERFLUX 3070
24 Pages
-
Temperature Catalogue
148 Pages
-
Gas & Steam Product Overview
5 Pages
-
Pressure Product Overview
32 Pages
-
Water & Wastewater
44 Pages
-
Food Applications
100 Pages
-
OPTITEMP TT 51
2 Pages
-
OPTIWAVE 5200
2 Pages
-
OPTIWAVE 6300
2 Pages
-
ALTOSONIC V12 Highlights
18 Pages
-
Energy (Oil & Gas)
44 Pages
-
VISCOLINE
2 Pages
-
OPTISONIC 7300
2 Pages
-
OPTIFLEX 2200
2 Pages
-
BM 26
2 Pages
-
OPTISONIC 3400
16 Pages
-
OPTIMASS 6400
16 Pages
-
MICRO-SET
12 Pages
-
IFC 100 | IFC 300
9 Pages
-
ALTOSONIC V12
18 Pages
-
Brochure Oil & Gas Industry
40 Pages
-
Brochure Energy Measurement
28 Pages
-
Brochure Energy (Oil and Gas)
44 Pages
-
OPTITEMP TR | TC 100
28 Pages
-
IFC 300 Converter
56 Pages
-
DW 18 SERIES
28 Pages
-
Brochure Bioenergy
12 Pages
Archived catalogs
-
Level Product Overview
50 Pages
-
CARGOMASTER
16 Pages
-
SDA Flap-type Flowmeter
2 Pages
-
DWM 1000 | 2000
20 Pages
-
UFM 3030
16 Pages
-
TR TC
28 Pages