Group: Krohne
Catalog excerpts
Flow measurement Product overview
Open the catalog to page 14-5 Product selection 6-7 Overview Technology Icons 8-9 Highlights of the KROHNE devices 10-19 Electromagnetic flowmeters 20-27 Variable area flowmeters KROHNE trademarks: KROHNE measure the facts CalSys CARGOMASTER EcoMATE EGM KROHNE Care M-PHASE OPTIBAR OPTIBATCH OPTIBRIDGE OPTIFLEX OPTIFLUX OPTIMASS OPTISENS OPTISONIC OPTISOUND OPTISWIRL OPTISWITCH OPTISYS OPTIWAVE PipePatrol WATERFLUX SENSOFIT SMARTMAC SMARTPAT 52-59 Differential pressure flow measurement Trademarks of other owners: Amphenol Bluetooth® EtherNet/IP™ FDT Group 70-71 Calibration FOUNDATION™ fieldbus HART® HASTELLOY®...
Open the catalog to page 2KROHNE – your global partner KROHNE is your reliable partner for process instrumentation and automation. As our client, you benefit from our ability to solve your applications with matching measurement solutions; we offer a complete product portfolio, industry specific system solutions and complementary services for instrumentation projects of any size. By having specialised in industrial process measurement since 1921, we have gained an enormous amount of application knowledge in various industries that is integrated into our products, solutions and services. We have truly mastered the...
Open the catalog to page 3The solution for every application KROHNE has unique expertise when it comes to flow measurement. We hold over 1,000 patents relating to flow products and don’t just demonstrate our ability with standard applications but also with applications that are demanding, requiring custom solutions. For us, customer orientation starts as early as research and development. Many of our products which are considered today’s industrial standards, were developed in cooperation with our customers. Today, users around the world benefit from KROHNE innovation: Electromagnetic flowmeters with ceramic liners...
Open the catalog to page 4Product selection Product selection list This table will help you in selecting the right measuring principle for your application Electro- magnetic flowmeters Variable area flowmeters Ultrasonic flowmeters Mass flowmeters Vortex flowmeters Differential pressure flow measurement Flow controllers High flow rates Non-conductive liquids Viscous media Industrial gases High flow rates Slurry, media with solids Emulsions (oil/water) Corrosive liquids (acids, alkalis) Bi-directional measurements Special applications
Open the catalog to page 5Overview Technology Icons Technology Icons To deliver reliable values even under difficult conditions, KROHNE products and solutions use a number of high-end technologies. These are highlighted by the technology icons, each representing a unique and characteristic feature that also generates additional benefit for users: Ceramic durability By implementing oxide ceramic sensors into OPTIFLUX and BATCHFLUX electromagnetic flowmeters as well as ceramic diaphragms into OPTIBAR pressure devices, KROHNE is using a superior material that is permanently resistant to corrosive and abrasive media and...
Open the catalog to page 6Overview Technology Icons transmitter built-in Transmitter built-in The SMARTPAT series of analysis sensors significantly eases the handling of analytical sensors: formerly an external device, the transmitter has now been miniaturised and built into the sensor head, enabling direct 4...20 mA/HART® 7 communication. This reduces the costs of ownership, eases installation and maintenance, and allows for usage in Ex applications (zone 0). computer built-in Flow computer built-in Many KROHNE flowmeters have a built-in flow computer that compensates for the effects of pressure and temperature on...
Open the catalog to page 7Highlights of the KROHNE devices GDC concept: An electronics concept from which everybody benefits MFC 400 for mass flowmeters UFC 400 for ultrasonic flowmeters User-friendliness is traditionally a top priority at KROHNE: whether during installation, commissioning, operation or communication – high-end technology only makes sense if it is simple and convenient for the customer to use. That is why at KROHNE, user-friendliness begins with the electronics. Our development and application engineers have worked for years to develop a comprehensive design known as the General Device Concept – GDC...
Open the catalog to page 8Human Machine Interface (HMI): Simply clever, simply well thought-out User-friendliness begins with selecting the right display and control elements. All devices feature a large, high-contrast display which makes it possible to display plain text information as well as graphic information such as the trend development of the flow. Operation is simple and convenient thanks to a user-friendly interface with four optical buttons. Not only does it look good – it’s also extremely practical. For example, the glass cover which protects the display from dirt and dust does not have to be removed...
Open the catalog to page 9The modular product line Converters IFC 050 C Display/Blind: Basic applications OPTIFLUX 2000 For water and wastewater applications WATERFLUX 3000 For small and large flows without requiring inlets or outlets Flow sensors OPTIFLUX 1000 Sandwich (wafer) device for compact installation OPTIFLUX 5000 sandwich, flange Ceramic measuring tube: maximum media and abrasion resistance and accuracy OPTIFLUX 6000 For hygienic food and pharmaceutical applications OPTIFLUX 4000 For standard and advanced process and custody transfer applications
Open the catalog to page 10OPTIFLUX 7300 C sandwich, flange With non wetted capacitive electrodes and ceramic liner BATCHFLUX 5500 For volumetric filling systems in the beverage industry TIDALFLUX 2300 F For partially filled pipelines, Ex Zone 1 POWERFLUX 4000 For nuclear applications POWERFLUX 5000 For nuclear applications, with ceramic measuring tube WATERFLUX 3070 Battery-powered water meter for district metering and custody transfer OPTICHECK Service tool for in-situ verification of field devices Electromagnetic flowmeters
Open the catalog to page 11Electromagnetic flowmeters Electromagnetic flowmeters Highlights: As early as 1832, Michael Faraday tried to determine the speed of the current in the Thames by measuring the voltage induced in flowing water by the earth’s magnetic field. Electromagnetic flow measurement is based on Faraday’s law of induction. According to this law, a voltage is induced when an electric conductive fluid flows through the magnetic field of an electromagnetic flowmeter. This voltage is proportional to the flow velocity of the medium. •• All KROHNE EMF are wet-calibrated in a direct comparison of volumes ••...
Open the catalog to page 12All KROHNE Messtechnik GmbH catalogs and technical brochures
-
LDM system Brochure en
28 Pages
-
Product Overview Brochure
84 Pages
-
OPTITEMP TRA/TCA PLUS
72 Pages
-
TIDALFLUX 2300 F
24 Pages
-
OPTISONIC 8300
40 Pages
-
OPTIBAR LC 1010
20 Pages
-
DWM1000/DWM2000
20 Pages
-
DW 181
28 Pages
-
OPTITEMP TRA-H6X/-C6X
36 Pages
-
HYG.Accessories
24 Pages
-
IFC 050 Handbook
84 Pages
-
IFC 050
32 Pages
-
BATCHFLUX 5500 C
28 Pages
-
AFC 030 Converter
32 Pages
-
AMADAS Analyser Management
4 Pages
-
CALSYS for metering
4 Pages
-
Virtual flow computer
4 Pages
-
OPTIMASS 1000 Marine
2 Pages
-
Optimass 2000
2 Pages
-
OPTIMASS 6000 Marine
2 Pages
-
OPTIFLEX 4300 C Marine
2 Pages
-
OPTIWAVE 8300 C Marine
4 Pages
-
Accessories hygienic instruments
12 Pages
-
C95 CI
4 Pages
-
C95 Digital Panel Meter
4 Pages
-
OPTISONIC 6300 P | 6400
2 Pages
-
Inertisation (VA meters)
2 Pages
-
Unconventional Energy Resources
18 Pages
-
Temperature measurement
40 Pages
-
Brochure Food and Beverages
58 Pages
-
Product Overview
64 Pages
-
BM 500
16 Pages
-
H250 M40
48 Pages
-
OPTIFLUX 1000
24 Pages
-
IFC 100
36 Pages
-
H250 M40
20 Pages
-
SMARTPAT Overview
16 Pages
-
WATERFLUX 3070
24 Pages
-
Temperature Catalogue
148 Pages
-
Gas & Steam Product Overview
5 Pages
-
Pressure Product Overview
32 Pages
-
Water & Wastewater
44 Pages
-
Food Applications
100 Pages
-
OPTITEMP TT 51
2 Pages
-
OPTIWAVE 5200
2 Pages
-
OPTIWAVE 6300
2 Pages
-
ALTOSONIC V12 Highlights
18 Pages
-
Energy (Oil & Gas)
44 Pages
-
VISCOLINE
2 Pages
-
OPTISONIC 7300
2 Pages
-
OPTIFLEX 2200
2 Pages
-
BM 26
2 Pages
-
OPTISONIC 3400
16 Pages
-
OPTIMASS 6400
16 Pages
-
MICRO-SET
12 Pages
-
IFC 100 | IFC 300
9 Pages
-
ALTOSONIC V12
18 Pages
-
Brochure Oil & Gas Industry
40 Pages
-
Brochure Energy Measurement
28 Pages
-
Brochure Energy (Oil and Gas)
44 Pages
-
OPTITEMP TR | TC 100
28 Pages
-
IFC 300 Converter
56 Pages
-
DW 18 SERIES
28 Pages
-
Brochure Bioenergy
12 Pages
Archived catalogs
-
Level Product Overview
50 Pages
-
CARGOMASTER
16 Pages
-
SDA Flap-type Flowmeter
2 Pages
-
DWM 1000 | 2000
20 Pages
-
UFM 3030
16 Pages
-
TR TC
28 Pages