Group: Krohne
Catalog excerpts
► Gain control of your fuel consumption Product overview I Systems for monitoring of fuel consumption and bunkering
Open the catalog to page 1Payback through reliable and accurate measurements Dependable measurements can give potential for significant savings in fuel consumption. Additional parameters such as measurement errors, leakage, pressure loss and maintenance should also be taken into consideration to achieve increased efficiency. Gain control of your fuel consumption The EcoMATE® system is offering reliability in measurement accuracy, as well as maintenance free operation during a long life onboard. Software provides easy-to-understand monitoring and automated reporting functions. KROHNE Skarpenord - the marine center of...
Open the catalog to page 2What can the EcoMATE® system do for you? EcoMATE® software An EcoMATE® system can be set up for monitoring of fuel consumption and/or bunkering onboard ships. Based on our robust and accurate flowmeters we can offer: • Fuel consumption monitoring Monitoring and reporting of fuel consumption measured in the supply (and return) line to main engine and other consumers onboard The EcoMATE® software provides easy to understand monitoring and reporting of consumption of fuel and bunker received. All relevant data is logged and stored in the system database. At any time, the operator may view...
Open the catalog to page 3Smooth sailing with EcoMATE® onboard Fuel consumption monitoring at a glance • Monitoring of momentary fuel consumption • Monitoring of momentary fuel consumption pr. distance, longitudinal water speed • Momentary CO2 and SOx emissions • Accumulated total fuel consumption and emissions for currant voyage Shift-over detection: The OPTIMASS flowmeters will automatically measure and report a change in liquid density and temperature. This may be used for documenting a shiftover from HFO (sulphuric) to MDO/MGO. EcoMATE® - Fuel consumption monitoring Accurate measurements and monitoring of your...
Open the catalog to page 4Quantity and quality is always under control Bunkering verification at a glance • Verification of total amount (mass) and density of bunker received through the bunker line • Trend for mass flow, density and temperature • Density deviation alarm Warning messages: The system can generate warnings and alarms when a certain proportion of gas bubbles is exceeded. EcoMATE® - Bunkering verification OPTIMASS 2000 - The first choice for verifying bunkering operations • Direct measurement of fuel mass flow, density and temperature Fuel oil costs represent the biggest share of a vessel’s total...
Open the catalog to page 5OPTIMASS Coriolis mass flowmeters Coriolis measuring principle Highlights OPTIMASS flowmeters • One flowmeter allows multiple measured values: mass flow - density - temperature • The mass of a product does not change with pressure, temperature or viscosity • The measurement is not affected by flow profile - no requirement for straight inlet/outlet sections • High accuracy • Fully welded maintenance free measuring tubes in stainless steel Coriolis mass flowmeters have significant advantages over other flow measurement methods as they directly measures mass flow, liquid density and process...
Open the catalog to page 6KROHNE Skarpenord’s marine world wide network of support Sales Agents Service Stations For more information and offers/quotes, do not hesitate to contact us Head office KROHNE Skarpenord Stromtangveien 21 NO-3950 Brevik, NORWAY Tel: +47 35 56 12 20 Fax: +47 35 56 12 21 support@krohne.no Service Stations and Sales Agents The current list of all KROHNE Skarpenord Service Stations and Sales Agents can be found at: www.krohne-skarpenord.com
Open the catalog to page 7All KROHNE Messtechnik GmbH catalogs and technical brochures
-
LDM system Brochure en
28 Pages
-
Product Overview Brochure
84 Pages
-
OPTITEMP TRA/TCA PLUS
72 Pages
-
TIDALFLUX 2300 F
24 Pages
-
OPTISONIC 8300
40 Pages
-
OPTIBAR LC 1010
20 Pages
-
DWM1000/DWM2000
20 Pages
-
DW 181
28 Pages
-
OPTITEMP TRA-H6X/-C6X
36 Pages
-
Flow measurement
72 Pages
-
HYG.Accessories
24 Pages
-
IFC 050 Handbook
84 Pages
-
IFC 050
32 Pages
-
BATCHFLUX 5500 C
28 Pages
-
AFC 030 Converter
32 Pages
-
AMADAS Analyser Management
4 Pages
-
CALSYS for metering
4 Pages
-
Virtual flow computer
4 Pages
-
OPTIMASS 1000 Marine
2 Pages
-
Optimass 2000
2 Pages
-
OPTIMASS 6000 Marine
2 Pages
-
OPTIFLEX 4300 C Marine
2 Pages
-
OPTIWAVE 8300 C Marine
4 Pages
-
Accessories hygienic instruments
12 Pages
-
C95 CI
4 Pages
-
C95 Digital Panel Meter
4 Pages
-
OPTISONIC 6300 P | 6400
2 Pages
-
Inertisation (VA meters)
2 Pages
-
Unconventional Energy Resources
18 Pages
-
Temperature measurement
40 Pages
-
Brochure Food and Beverages
58 Pages
-
Product Overview
64 Pages
-
BM 500
16 Pages
-
H250 M40
48 Pages
-
OPTIFLUX 1000
24 Pages
-
IFC 100
36 Pages
-
H250 M40
20 Pages
-
SMARTPAT Overview
16 Pages
-
WATERFLUX 3070
24 Pages
-
Temperature Catalogue
148 Pages
-
Gas & Steam Product Overview
5 Pages
-
Pressure Product Overview
32 Pages
-
Water & Wastewater
44 Pages
-
Food Applications
100 Pages
-
OPTITEMP TT 51
2 Pages
-
OPTIWAVE 5200
2 Pages
-
OPTIWAVE 6300
2 Pages
-
ALTOSONIC V12 Highlights
18 Pages
-
Energy (Oil & Gas)
44 Pages
-
VISCOLINE
2 Pages
-
OPTISONIC 7300
2 Pages
-
OPTIFLEX 2200
2 Pages
-
BM 26
2 Pages
-
OPTISONIC 3400
16 Pages
-
OPTIMASS 6400
16 Pages
-
MICRO-SET
12 Pages
-
IFC 100 | IFC 300
9 Pages
-
ALTOSONIC V12
18 Pages
-
Brochure Oil & Gas Industry
40 Pages
-
Brochure Energy Measurement
28 Pages
-
Brochure Energy (Oil and Gas)
44 Pages
-
OPTITEMP TR | TC 100
28 Pages
-
IFC 300 Converter
56 Pages
-
DW 18 SERIES
28 Pages
-
Brochure Bioenergy
12 Pages
Archived catalogs
-
Level Product Overview
50 Pages
-
CARGOMASTER
16 Pages
-
SDA Flap-type Flowmeter
2 Pages
-
DWM 1000 | 2000
20 Pages
-
UFM 3030
16 Pages
-
TR TC
28 Pages