Group: Krohne
Catalog excerpts
Technical Datasheet Electromagnetic Flow Switch and Flow Meter • For measuring electrically-conductive liquids, pastes and slurries • Optional digital display • No moving parts, maintenance-f
Open the catalog to page 1The electromagnetic flow controller The DWM 1000 electromagnetic flow switch and the DWM 2000 electromagnetic flow meter monitor the flow of electrically-conductive liquids, pastes and slurries. The DWM 1000 uses an induced voltage converted into a switching signal. The DWM 2000 uses an induced voltage converted into a 4...20 mA current output that is proportional to the flow velocity. Highlights • DIP switch for setting full-scale value • Zero calibration button removes zero drift • Long version available for pipes larger than 400 mm / 16" in diameter • Optional ball valve for long version...
Open the catalog to page 2Variants DWM 1000 The DWM 1000 flow switch is an insertion-type, two wire system. The switching point is adjustable over a full-scale range of 0.1...9.9 m/s or 0.3...32.5 ft/s. Amplifier relays are also available for a selection of AC and DC voltages. A welding socket is supplied as standard for welding the DWM 1000 directly onto process pipes. It is suitable for pipe diameters DN50...400. An optional spool piece can be used to install the instrument without a welding operation. DWM 2000 The DWM 2000 flow meter is an insertion-type instrument. Full scale range is a adjustable from 1...8 m/s...
Open the catalog to page 3Options LCD Indicator The DWM 2000 D flow meter is equipped with a two-line, 16-character LCD. It indicates flow velocity on the first line and flow rate on the second. It can also be used to calibrate the DWM 2000 onsite. This can be retrofitted to all DWM 2000 variants, except those with the IP68 stainless steel housing option. IP68 stainless steel housing The IP68 stainless steel housing has been designed for immersed applications. It is a sealed unit and all calibration is carried out before delivery. DWM 1000 and 2000 instruments with the IP68 stainless steel housing option can also be...
Open the catalog to page 4Spooling piece Spooling pieces are available for pipe diameters DN25...50 or 1...2". These have a standard length of 200 mm / 7.9". FT Tuchenhagen connection An option developed for hygienic applications. Tuchenhagen VARIVENT® housings are supplied on demand with DWM 1000 FT and 2000 FT instruments.
Open the catalog to page 5Flow meter with 4…20 mA output For monitoring flow velocity in pipes or open channels User interface Options None; 2-line LCD indicator with 4-button keypad Interface languages English, French or German Display units, 1st line Display units, 2nd line (optional) ±5% of the measured value (± 2% if calibrated onsite) Measurement accuracy Repeatability Accuracy Reference temperature Reference pressure 1013 mbar abs. ±20 mbar / 14.69 psig ±0.29 psig Reference relative humidity Full-scale range 8%, when flow velocity decreas
Open the catalog to page 6Operating conditions Ambient temperature Process temperature without stainless steel housing (IP68) option with stainless steel housing (IP68) option Max. allowable operating pressure Electrical conductivity Protection category acc. to EN 60529 standard variant with long sensor option with stainless steel housing (IP68) option Installation conditions Minimum inlet run 10 x nominal diameter, depending on the flow profile 5 x nominal diameter, depending on the flow profile Pipe material Electrically conductive materials, refer to the handbook for other materials
Open the catalog to page 7Materials Housing without stainless steel housing (IP68) option Aluminium with epoxy finish with stainless steel housing (IP68) option Sensor casing Sensor insulation Ceramic (Zirconium oxide) Welding sleeve for T-mounting Spool piece (option) Safety chain, for long sensor option Zinc-plated steel Isolation valve (option) Nickel-plated brass Tuchenhagen connection (option) Cable entry Nickel-plated brass Gasket, sensor Gasket, connection Klingerit (without asbestos) Gasket, housing cover Gasket, Tuchenhagen connection (option) Process connections with standard fitting G 1A; Screw-on welding...
Open the catalog to page 8Instrument terminal Relay options for instrument terminal Power consumption Protective earthing load 1 Cable entry Cable tightening capacity Length of cable for stainless steel housing (IP68) option Time constant Power supply Input and output Output signal Options Options Spooling piece, see also "Process connections" IP 68 stainless steel housing; Long sensor, 500 mm / 20" length; Long sensor, 1000 mm / 40" length (up to 3 m / 10 ft on request) Welding socket G 1½ isolation valve, for long sensor option NPT 1½ process connection adapter, for G 1½ isolation valve Relay - Digital indicator C...
Open the catalog to page 9Dimensions and Weight Standard sub-variants 1 DWM 1000 or DWM 2000 with optional welding socket 2 DWM 2000 D (with LCD indicator) with optional welding socket 3 DWM 1000 or DWM 2000 with spool piece for inline connection • PG13.5 cable glands are supplied as standard • LCD indicators can be retrofitted to all DWM 2000s with aluminium housings
Open the catalog to page 10Standard sub-variants without spool piece: Dimensions and Weight in mm and kg Dimensions [mm] a Without LCD indicator Standard sub-variants without spool piece: Dimensions and Weight in inches and lbs Dimensions [inches] a Standard sub-variants with spool piece: Dimensions and Weight in mm and kg Dimensions [mm] ND With spool piece, PN40 With spool piece, ANSI 150 lbs With spool piece, ANSI 300 lbs Standard sub-variants with spool piece: Dimensions and Weight in inches and lbs Dimensions [inches] ND With spool piece, PN40 With spool piece, ANSI 150 lbs With spool piece, ANSI 300 lbs
Open the catalog to page 11Long sub-variants 1 DWM 1000 L or DWM 2000 L with safety chain, optional G 1½ isolation valve and optional welding socket or NPT 1½ adaptor 2 DWM 2000 L with LCD indicator, safety chain, optional G 1½ isolation valve and optional welding socket or NPT 1½ adaptor • PG13.5 cable glands are supplied as standard • A safety chain is supplied as standard with DWM 1000 L and DWM 2000 L instruments • LCD indicators can be retrofitted to all DWM 2000s with aluminium housings
Open the catalog to page 12All KROHNE Messtechnik GmbH catalogs and technical brochures
-
LDM system Brochure en
28 Pages
-
Product Overview Brochure
84 Pages
-
OPTITEMP TRA/TCA PLUS
72 Pages
-
TIDALFLUX 2300 F
24 Pages
-
OPTISONIC 8300
40 Pages
-
OPTIBAR LC 1010
20 Pages
-
DW 181
28 Pages
-
OPTITEMP TRA-H6X/-C6X
36 Pages
-
Flow measurement
72 Pages
-
HYG.Accessories
24 Pages
-
IFC 050 Handbook
84 Pages
-
IFC 050
32 Pages
-
BATCHFLUX 5500 C
28 Pages
-
AFC 030 Converter
32 Pages
-
AMADAS Analyser Management
4 Pages
-
CALSYS for metering
4 Pages
-
Virtual flow computer
4 Pages
-
OPTIMASS 1000 Marine
2 Pages
-
Optimass 2000
2 Pages
-
OPTIMASS 6000 Marine
2 Pages
-
OPTIFLEX 4300 C Marine
2 Pages
-
OPTIWAVE 8300 C Marine
4 Pages
-
Accessories hygienic instruments
12 Pages
-
C95 CI
4 Pages
-
C95 Digital Panel Meter
4 Pages
-
OPTISONIC 6300 P | 6400
2 Pages
-
Inertisation (VA meters)
2 Pages
-
Unconventional Energy Resources
18 Pages
-
Temperature measurement
40 Pages
-
Brochure Food and Beverages
58 Pages
-
Product Overview
64 Pages
-
BM 500
16 Pages
-
H250 M40
48 Pages
-
OPTIFLUX 1000
24 Pages
-
IFC 100
36 Pages
-
H250 M40
20 Pages
-
SMARTPAT Overview
16 Pages
-
WATERFLUX 3070
24 Pages
-
Temperature Catalogue
148 Pages
-
Gas & Steam Product Overview
5 Pages
-
Pressure Product Overview
32 Pages
-
Water & Wastewater
44 Pages
-
Food Applications
100 Pages
-
OPTITEMP TT 51
2 Pages
-
OPTIWAVE 5200
2 Pages
-
OPTIWAVE 6300
2 Pages
-
ALTOSONIC V12 Highlights
18 Pages
-
Energy (Oil & Gas)
44 Pages
-
VISCOLINE
2 Pages
-
OPTISONIC 7300
2 Pages
-
OPTIFLEX 2200
2 Pages
-
BM 26
2 Pages
-
OPTISONIC 3400
16 Pages
-
OPTIMASS 6400
16 Pages
-
MICRO-SET
12 Pages
-
IFC 100 | IFC 300
9 Pages
-
ALTOSONIC V12
18 Pages
-
Brochure Oil & Gas Industry
40 Pages
-
Brochure Energy Measurement
28 Pages
-
Brochure Energy (Oil and Gas)
44 Pages
-
OPTITEMP TR | TC 100
28 Pages
-
IFC 300 Converter
56 Pages
-
DW 18 SERIES
28 Pages
-
Brochure Bioenergy
12 Pages
Archived catalogs
-
Level Product Overview
50 Pages
-
CARGOMASTER
16 Pages
-
SDA Flap-type Flowmeter
2 Pages
-
DWM 1000 | 2000
20 Pages
-
UFM 3030
16 Pages
-
TR TC
28 Pages