Technical Datasheet Mechanical Flow Controller • Mechanical, autonomous flow switches - no power supply needed • For horizontal and vertical pipes from DN 15 up to DN 3000 - and higher • High reliability and repeatability up to 300°C / 570°F
Open the catalog to page 1The Mechanical Flow Controller The DW 18 series of flow controller is ideal for locally indicating the flow of homogenous clean liquids. Adjustable switches generate alarms once switching points are reached. The units are robust. Several variants are available to suit a wide variety of applications. • Proven technology - for more than thirty years • Bistable reed switches, SPDT switches and relays • Optional second limit switch • Switch position can be adjusted under process • High-temperature version (without indicator) for • Housing is removable under process conditions • Optional...
Open the catalog to page 2The DW 181 inline flow controller is suitable for horizontal orvertical pipes. It can have G or NPT threaded connections, sizes ranging from %...2". The measuring tube and connection are made of either bronze or 316 L (1.4404) stainless steel. There are two types of indicator available for this variant: • a linear scale with up to two alarm positions at the top and bottom of the indicator (as shown) or • a dial which has been made specifically for this instrument and tested on a calibration rig. For information on DW 181 flow ranges, please refer to the flow range tables. The DW 182 inline...
Open the catalog to page 3The DW 183 inline flow controller is suitable for horizontal or vertical pipes. It has with flanged connections , sizes ranging from DN 65...DN 200 and 21/4...8". The measuring tube and connection is made of eitherXC 18 (1020) carbon steel or 316 L (1.4404) stainless steel. Carbon steel flanges with nominal diameters bigger than 100 or 4" can have 316 L stainless steel cladding. There are two types of indicator available for this variant: • a linear scale with up to two alarm positions at • a dial (as shown) which has been made specifically for this instrument and tested on a For...
Open the catalog to page 4Indicator options Standard and intrinsically-safe flow switches are equipped with a local indicator. There are two types: O The type G linear indicator is supplied as standard for all vari- ants. Up to two switching points (alarm positions] are indicated at the top and the bottom of the indicator. The switching points are set according to customer order and tested on a calibration rig. Switching points can be changed during operation. 0 The type A dial indicator is optional for the DW 181, DW 182 and DW 183. It has been made specifically for the instrument and tested on a calibration rig....
Open the catalog to page 5ATEX approval: explosion-proof devices The DW 18 explosion-proof (EEx d) flow switch has an aluminium housing without an indicator. It is suitable for use in potentially explosive atmospheres. It is possible to change the switch position under process conditions. A DW 18 with this option is in equipment category The DW 18 high-temperature (HT) flow switch is suitable for operating conditions up to 300°C / 570°F. It does not have an indicator. The switch is sheathed in a PTFE cartridge. It is possible to change the switch position under process conditions.
Open the catalog to page 6Technical data: inline instruments Installation type Inline connection Measurement accuracy Operating conditions
Open the catalog to page 7Installation conditions Process connections
Open the catalog to page 8© Not available for EEx d and HT options. For connection sizes DN <100 or <4" only. © With type A dial only 0 With type A dial only © See flow range tables 0 NPT connections: 316 L (1.4404) stainless steel only © Carbon steel flanges with nominal diameters bigger than 100 mm or 4" can have stainless steel cladding © no indicator available for the EEx d version. EEx approval not available for the high-temperature option. Refer also to the "Switch op- tions" page.
Open the catalog to page 9Technical data: insertion-type instruments Installation type Insertion-type connection for pipe diameters >DN250 or 10" Measurement accuracy Operating conditions
Open the catalog to page 10Installation conditions Process connections Power supply Instrument terminal Refer to the "Switch options" page O No indicator available for the EEx d version. EEx approval not available for the high-temperature option. Refer also to the "Switch op- tions" page.
Open the catalog to page 11Switch options The DW 18 series has a large number of switch and relay options. The DW 18 series can be equipped with either: 1 or 2 SPST (single pole, single throw) switches for standard applications, 1 or 2 SPST switches for high-temperature (HT) applications, 1 SPDT (single pole, double throw) switch, or 1 or 2 DPDT (double pole, double throw) relay amplifiers for higher switching capacities. The normal state of an SPST switch is either N/C, normally closed, or N/0, normally open. N/C switches are closed during operation (closed when flow increases). N/0 switches are open during...
Open the catalog to page 12Power supply O With high-temperature (HT) option. EEx approvals are not available.
Open the catalog to page 13Flow range tables Use the tables that follow for the selection of devices and their flow range. Quote the code given. O only with indicator G
Open the catalog to page 14O only with indicator G
Open the catalog to page 16DW 184 flow velocity ranges O mounting flange size for insertion-type flow controller. For process pipes diameters >250 mm/10" in diameter.
Open the catalog to page 18DW181 non-Ex/Exi side view • The customer must supply cable glands for EEx d-approved flow controllers with Aluminium housings. The standard size for the cable entry is M20 x 1.5. M25 x 1.5 and NPT VA cable entries are also available • Standard and EEx i-approved flow controllers have PG 13.5 cable glands. • High-temperature flow controllers have PG 9 cable glands.
Open the catalog to page 19DW 182 non-Ex / Exi side view
Open the catalog to page 21DW 184 non-Ex/Exi side view O mounting flange size for DW 184 insertion-type flow controller. For process pipe diameters O mounting flange size for DW 184 insertion-type flow controller. For process pipe diameters
Open the catalog to page 24All KROHNE Messtechnik GmbH catalogs and technical brochures
-
LDM system Brochure en
28 Pages
-
Product Overview Brochure
84 Pages
-
OPTITEMP TRA/TCA PLUS
72 Pages
-
TIDALFLUX 2300 F
24 Pages
-
OPTISONIC 8300
40 Pages
-
OPTIBAR LC 1010
20 Pages
-
DWM1000/DWM2000
20 Pages
-
DW 181
28 Pages
-
OPTITEMP TRA-H6X/-C6X
36 Pages
-
Flow measurement
72 Pages
-
HYG.Accessories
24 Pages
-
IFC 050 Handbook
84 Pages
-
IFC 050
32 Pages
-
BATCHFLUX 5500 C
28 Pages
-
AFC 030 Converter
32 Pages
-
AMADAS Analyser Management
4 Pages
-
CALSYS for metering
4 Pages
-
Virtual flow computer
4 Pages
-
OPTIMASS 1000 Marine
2 Pages
-
Optimass 2000
2 Pages
-
OPTIMASS 6000 Marine
2 Pages
-
OPTIFLEX 4300 C Marine
2 Pages
-
OPTIWAVE 8300 C Marine
4 Pages
-
Accessories hygienic instruments
12 Pages
-
C95 CI
4 Pages
-
C95 Digital Panel Meter
4 Pages
-
OPTISONIC 6300 P | 6400
2 Pages
-
Inertisation (VA meters)
2 Pages
-
Unconventional Energy Resources
18 Pages
-
Temperature measurement
40 Pages
-
Brochure Food and Beverages
58 Pages
-
Product Overview
64 Pages
-
BM 500
16 Pages
-
H250 M40
48 Pages
-
OPTIFLUX 1000
24 Pages
-
IFC 100
36 Pages
-
H250 M40
20 Pages
-
SMARTPAT Overview
16 Pages
-
WATERFLUX 3070
24 Pages
-
Temperature Catalogue
148 Pages
-
Gas & Steam Product Overview
5 Pages
-
Pressure Product Overview
32 Pages
-
Water & Wastewater
44 Pages
-
Food Applications
100 Pages
-
OPTITEMP TT 51
2 Pages
-
OPTIWAVE 5200
2 Pages
-
OPTIWAVE 6300
2 Pages
-
ALTOSONIC V12 Highlights
18 Pages
-
Energy (Oil & Gas)
44 Pages
-
VISCOLINE
2 Pages
-
OPTISONIC 7300
2 Pages
-
OPTIFLEX 2200
2 Pages
-
BM 26
2 Pages
-
OPTISONIC 3400
16 Pages
-
OPTIMASS 6400
16 Pages
-
MICRO-SET
12 Pages
-
IFC 100 | IFC 300
9 Pages
-
ALTOSONIC V12
18 Pages
-
Brochure Oil & Gas Industry
40 Pages
-
Brochure Energy Measurement
28 Pages
-
Brochure Energy (Oil and Gas)
44 Pages
-
OPTITEMP TR | TC 100
28 Pages
-
IFC 300 Converter
56 Pages
-
Brochure Bioenergy
12 Pages
Archived catalogs
-
Level Product Overview
50 Pages
-
CARGOMASTER
16 Pages
-
SDA Flap-type Flowmeter
2 Pages
-
DWM 1000 | 2000
20 Pages
-
UFM 3030
16 Pages
-
TR TC
28 Pages