C 95 Digital Panel Meters Programmable ± 10,000 points The C 95 is one of a series of highly accurate digital panel meters. Each instrument has a highly legible 10,000-point 5-digit red display, whose brightness is ideally suited to use in industrial control rooms. The C 95 is the perfect choice for displaying. Monitoring and transmission of process data from any source in the plant. A simple 4-key touch-button control facilitates programming and subsequent operation. DC current or voltage Bidirectional ±100 mV, ±1 V, ±10 V, ±300 V, 20mA Analog output: 3 types available A1: Active current output 0/4...20 mA • Accuracy 0.1 % in relation to display (at +25°C) • Residual drift ≤ 0.2% • Admissible load: 0 Ω 2 kΩ (voltage) • Programmable scale ratio with enlarging effect • Response time: 40 ms Relay output: 2 types available R: 2 set point relays, independently programmable R4: 4 set point relays, independently programmable • Hysteresis independently programmable from 0 to 100% of set point in the display unit • Temporisation independently programmable from 0 to 25 s in 0.1 s steps • NO-NC contact 8 A - 250 V on resistive load Digital output N: Data link RS485 (2 wires) • Protocols MODBUS-JBUS data format: Integer / double integer • Slave number programmable from 1 to 255 with a rate from 1200 to 19200 Bauds Accuracy 0.05% of full scale at +25 °C Thermal drift < 150 ppm/°C Scale overlapping measurable from -5% to +5% Programmable scale factor Enlarging effect - Square root extraction Special linearisation 20 points Supply for 2 or 3 wire sensor 26 VDC
Open the catalog to page 1Panel Meter C 95 Technical Data Display Approx. 10,000 points (14 mm) Electroluminescent red (green as option) 4 alarm messages -10 000 / +100 000 points (14 mm) (as option); -2 000 / +10 000 points (20 mm) Features Sampling times Input impedance Drop Rejection rate Insulation 100 ms ≥ 1 MΩ for voltage inputs 0.9 V max. for current input Common mode: 130 dB Mode series: 70 dB 50/60 Hz Input / Output: 2.5 kV eff. 50Hz-1min Inputs / Power Supply: 2.5 kV eff., 50 Hz- 1min Zero drift compensation and self-calibration Programmable integration index Allows stabilising display in case of unsteady...
Open the catalog to page 2Approvals Emission and immunity in industrial environment CE EN 50081-2; EN 50082-2 EN 61000-4-2 level 3, EN 61000-4-3 level 3, EN 61000-4-4 level 4, EN 61000-4-6 level 3 According to directive CEM 89-336 Environment Front face protection IP 65 Operating temperature -5...55°C Storage temperature -30°C...+80°C Relative dampness 80% annual average Weight with / without output board 250g / 150g Connection with screwed plug-off connectors (for 2.5 mm² cable, flexible or single strand) Case in self-extinguishing black UL 94 VO ABS Electrical connections Locations of options and combinations Any...
Open the catalog to page 3Access code An access code settable from 0000 to 9999 prevents unauthorised programming of indicator, set points and locks access to some functions. The factory code is 0000. 0-5 6-9 Access to fast entering of alarm set-points No access 0-5 6-9 Access to function “tare” (except t° inputs) No access 0-5 6-9 Access to measurement and output simulations No access 0-5 6-9 Access to shifted scales No access Ordering code Output options: A Analogue R 2 relays R4 4 relays N Digital link (RS 485 2 wires) Power supply: 2 High voltage 3 Low voltage This instrument is designed for industrial...
Open the catalog to page 4All KROHNE Messtechnik GmbH catalogs and technical brochures
-
LDM system Brochure en
28 Pages
-
Product Overview Brochure
84 Pages
-
OPTITEMP TRA/TCA PLUS
72 Pages
-
TIDALFLUX 2300 F
24 Pages
-
OPTISONIC 8300
40 Pages
-
OPTIBAR LC 1010
20 Pages
-
DWM1000/DWM2000
20 Pages
-
DW 181
28 Pages
-
OPTITEMP TRA-H6X/-C6X
36 Pages
-
Flow measurement
72 Pages
-
HYG.Accessories
24 Pages
-
IFC 050 Handbook
84 Pages
-
IFC 050
32 Pages
-
BATCHFLUX 5500 C
28 Pages
-
AFC 030 Converter
32 Pages
-
AMADAS Analyser Management
4 Pages
-
CALSYS for metering
4 Pages
-
Virtual flow computer
4 Pages
-
OPTIMASS 1000 Marine
2 Pages
-
Optimass 2000
2 Pages
-
OPTIMASS 6000 Marine
2 Pages
-
OPTIFLEX 4300 C Marine
2 Pages
-
OPTIWAVE 8300 C Marine
4 Pages
-
Accessories hygienic instruments
12 Pages
-
C95 CI
4 Pages
-
OPTISONIC 6300 P | 6400
2 Pages
-
Inertisation (VA meters)
2 Pages
-
Unconventional Energy Resources
18 Pages
-
Temperature measurement
40 Pages
-
Brochure Food and Beverages
58 Pages
-
Product Overview
64 Pages
-
BM 500
16 Pages
-
H250 M40
48 Pages
-
OPTIFLUX 1000
24 Pages
-
IFC 100
36 Pages
-
H250 M40
20 Pages
-
SMARTPAT Overview
16 Pages
-
WATERFLUX 3070
24 Pages
-
Temperature Catalogue
148 Pages
-
Gas & Steam Product Overview
5 Pages
-
Pressure Product Overview
32 Pages
-
Water & Wastewater
44 Pages
-
Food Applications
100 Pages
-
OPTITEMP TT 51
2 Pages
-
OPTIWAVE 5200
2 Pages
-
OPTIWAVE 6300
2 Pages
-
ALTOSONIC V12 Highlights
18 Pages
-
Energy (Oil & Gas)
44 Pages
-
VISCOLINE
2 Pages
-
OPTISONIC 7300
2 Pages
-
OPTIFLEX 2200
2 Pages
-
BM 26
2 Pages
-
OPTISONIC 3400
16 Pages
-
OPTIMASS 6400
16 Pages
-
MICRO-SET
12 Pages
-
IFC 100 | IFC 300
9 Pages
-
ALTOSONIC V12
18 Pages
-
Brochure Oil & Gas Industry
40 Pages
-
Brochure Energy Measurement
28 Pages
-
Brochure Energy (Oil and Gas)
44 Pages
-
OPTITEMP TR | TC 100
28 Pages
-
IFC 300 Converter
56 Pages
-
DW 18 SERIES
28 Pages
-
Brochure Bioenergy
12 Pages
Archived catalogs
-
Level Product Overview
50 Pages
-
CARGOMASTER
16 Pages
-
SDA Flap-type Flowmeter
2 Pages
-
DWM 1000 | 2000
20 Pages
-
UFM 3030
16 Pages
-
TR TC
28 Pages