Group: Krohne
Catalog excerpts
C 95 CI Digital Panel Meter Integrator/Totalizer Display : ±100 000 pts for the instant value and on 6 digits for the integrator One bi-directional DC current or voltage input ±100mV, ±1V, ±10V, ±300V, ±20mA. Linear input with or without square root extraction and special curve in 20 points (programming in X and Y) Supply for 2 or 3 wire sensor 26 Vdc / 100 mA Integrator function with time basis and programmable conversion factor Totalizer saving in case of power supply cut Bargraph enables quick visualising of the instant or cumulated value, independently from display Current or voltage input Bi-directional ±100mV, ±1V, ±10V, ±300V, ±20mA. LOGIC: 2 insulated LOGIC inputs Analogue output: A: Active current output 0/4-20mA Relay output R: 2 relays Digital output N: Data link RS485 (2 wires) Accuracy 0.05 % of full scale at +25 °C Thermic drift < 150 ppm/°C. Scale overlapping measurable from -5% to +5%. Programmable scale factor Enlarging effect - Square root extraction Special linearisation 20 points. Supply for 2 or 3 wire sensor (current input) 26 VDC (±15%) -25 mA protected from short-circuits. Display blocking Totalizer zero reset / Integration stop and start Tare function Min. and max. zero reset Display change Accuracy 0.1 % in relation to display (at +25°C) Residual drift ≤ 0,2% Admissible load: 0 Ω < Rc < 500 Ω (current) Rc > 2 kΩ (voltage) Programmable scale ratio with enlarging effect on the instant or cumulated value Response time : 40 ms NO-NC contact 8 A...250 V on resistive load Independently programmable Mode pulses : duration 100, 200, ou 400 ms; pulse weight adjustable from 1 to 10 000 Mode alarm : set-point or window on the instant or cumulated value Hysteresis programmable in the display unit Time delay programmable from 0 to 25 s. in 0.1s increases Protocols MODBUS-JBUS data format : integer / double
Open the catalog to page 1Panel Meter C 95CI Technical data Display Instant value on 5 digits (14 mm), ±100 000 points Cumulated value on 6 digits (14 mm), from -100 000 to +1 000 000 points associated with a counter of overstepping (±1000) for a maximum counting from -100 000 000 to +1 000 000 000 points. Led indicating the type of value on display. Features Sampling time Input impedance Drop Rejection rate Insulation 100 ms, 20 ms, 16.6 ms ≥1 MΩ for voltage inputs 0.9 V max. for current input Common mode: 130 dB Mode series: 70 dB 50/60 Hz Inputs / Power Supply: 2,5 kV eff. 50Hz-1min Input / Output: 2,5 kV eff....
Open the catalog to page 2Connectors Fast reading on the display Simulation function Plug-off connectors on rear side for screwed connections (2.5mm², flexible or rigid) Set-point values Input signal electrical value Min. and max. values Overstepping counter Possible simulation of analog output (mode simulation). Simulation of instant or cumulated measure possible : allows validation of the analog output and relay outputs configuration in the system Power supply High Voltage Low Voltage Power draw Protection Front face Case/terminals Standards Complies with standards on emission and on immunity in industr....
Open the catalog to page 3Panel Meter C 95CI Power supply Process input Logic inputs Active current Access code An access code settable from 00000 to 59999 prevents unauthorised programming of indicator, set-points and locks access to some functions. The factory code is 00000. 0-5 6-9 Access to shifted scales No access 0-5 6-9 Access to measure and output simulations No access 0-5 6-9 Access to function “tare” No access 0-5 6-9 Access to fast entering of alarm set-points No access 0-2 3-5 Access to totalizer zero reset menu No access X Codification Output options: A Analog R 2 relays N Digital link (RS 485 2 wires)...
Open the catalog to page 4All KROHNE Messtechnik GmbH catalogs and technical brochures
-
LDM system Brochure en
28 Pages
-
Product Overview Brochure
84 Pages
-
OPTITEMP TRA/TCA PLUS
72 Pages
-
TIDALFLUX 2300 F
24 Pages
-
OPTISONIC 8300
40 Pages
-
OPTIBAR LC 1010
20 Pages
-
DWM1000/DWM2000
20 Pages
-
DW 181
28 Pages
-
OPTITEMP TRA-H6X/-C6X
36 Pages
-
Flow measurement
72 Pages
-
HYG.Accessories
24 Pages
-
IFC 050 Handbook
84 Pages
-
IFC 050
32 Pages
-
BATCHFLUX 5500 C
28 Pages
-
AFC 030 Converter
32 Pages
-
AMADAS Analyser Management
4 Pages
-
CALSYS for metering
4 Pages
-
Virtual flow computer
4 Pages
-
OPTIMASS 1000 Marine
2 Pages
-
Optimass 2000
2 Pages
-
OPTIMASS 6000 Marine
2 Pages
-
OPTIFLEX 4300 C Marine
2 Pages
-
OPTIWAVE 8300 C Marine
4 Pages
-
Accessories hygienic instruments
12 Pages
-
C95 Digital Panel Meter
4 Pages
-
OPTISONIC 6300 P | 6400
2 Pages
-
Inertisation (VA meters)
2 Pages
-
Unconventional Energy Resources
18 Pages
-
Temperature measurement
40 Pages
-
Brochure Food and Beverages
58 Pages
-
Product Overview
64 Pages
-
BM 500
16 Pages
-
H250 M40
48 Pages
-
OPTIFLUX 1000
24 Pages
-
IFC 100
36 Pages
-
H250 M40
20 Pages
-
SMARTPAT Overview
16 Pages
-
WATERFLUX 3070
24 Pages
-
Temperature Catalogue
148 Pages
-
Gas & Steam Product Overview
5 Pages
-
Pressure Product Overview
32 Pages
-
Water & Wastewater
44 Pages
-
Food Applications
100 Pages
-
OPTITEMP TT 51
2 Pages
-
OPTIWAVE 5200
2 Pages
-
OPTIWAVE 6300
2 Pages
-
ALTOSONIC V12 Highlights
18 Pages
-
Energy (Oil & Gas)
44 Pages
-
VISCOLINE
2 Pages
-
OPTISONIC 7300
2 Pages
-
OPTIFLEX 2200
2 Pages
-
BM 26
2 Pages
-
OPTISONIC 3400
16 Pages
-
OPTIMASS 6400
16 Pages
-
MICRO-SET
12 Pages
-
IFC 100 | IFC 300
9 Pages
-
ALTOSONIC V12
18 Pages
-
Brochure Oil & Gas Industry
40 Pages
-
Brochure Energy Measurement
28 Pages
-
Brochure Energy (Oil and Gas)
44 Pages
-
OPTITEMP TR | TC 100
28 Pages
-
IFC 300 Converter
56 Pages
-
DW 18 SERIES
28 Pages
-
Brochure Bioenergy
12 Pages
Archived catalogs
-
Level Product Overview
50 Pages
-
CARGOMASTER
16 Pages
-
SDA Flap-type Flowmeter
2 Pages
-
DWM 1000 | 2000
20 Pages
-
UFM 3030
16 Pages
-
TR TC
28 Pages