Group: Krohne
Catalog excerpts
Intelligent solutions for the water and wastewater industry
Open the catalog to page 1From space, our earth is a blue planet with seemingly vast water resources. However, only 2.5 % of this water is usable fresh water. At the same time, the increase in global population and rapid industrialization put enormous demands on the natural water resources. Water is becoming rare in the future. Against this backdrop, it is clear how important it is to man and industry to have an efficient, high-capacity potable water supply and to have eco-friendly wastewater treatment for the planet as well as for thew development of entire regions. At the same time, the increasing competition in...
Open the catalog to page 3KROHNE - 90 years of experience Company founded as LUDWIG KROHNE & SOHN in Duisburg, Germany, production of variable area flowmeters for measuring the flow of air, gases and The beginning of manufacturing mechanical Level indicators for measuring Liquids in tanks and containers The first electromagnetic flowmeter (EMF) for water, The first EMF with pulsed direct current field excitation/automatic zero point offset for the water The first ultrasonic flowmeter for water, district The first non-analog, but frequency-based electronics for EMFs for improved flow measurement of wastewater and...
Open the catalog to page 4The first microprocessor-based electronics for cost- optimized manufacturing of EMFs for the water and wastewater industry The first EMF with capacitative pickup and without contacting the measuring electrodes with the medium for measuring such things as aliphatic sludges The first radar level meter (FMCW - microwaves) for process tanks and digestion towers The first straight tube Coriolis device for determining mass flow rate and density of polymers, methanol, activated carbon, sludge, etc. The first electromagnetic flowmeter with integrated capacitive level measurement for partially...
Open the catalog to page 58 Waterworks The Haltern waterworks – Responsible for the Rhine, Ruhr and Münsterland Water catchment Water treatment Pretreatment Aereatation/ Degassing Dosage Level Pressure Flow Conductivity Temperature Level Conductivity Pressure O2 Pressure Level NO3 pH Flow Temperature pH pH Level Pressure Flow Ultra-violet Infiltration Flocculation/ Sedimentation Flow Pressure Flow
Open the catalog to page 8The waterworks in the Westphalian town of Haltern Gelsenwasser AG, one of the Largest providers of potable water in Germany. With an annual delivery of around 105 million m3 of water, it ranks among the largest of its kind in Europe. The service area includes more than 20 communities of the northern Ruhr district and Munsterland. A total of a million people, including commerce and industry are reliably supplied with potable water and service water by the waterworks. 24 hours a day, 365 days a year. The Haltern waterworks is situated in a hydrogeologically favorable location, which owes its...
Open the catalog to page 9The well house - 100 % certainty, The untreated water is abstracted in the waterworks via groundwater wells or bank filtration wells and from dams and other types of surface water. A large number of waterworks have decided on the OPTIFLUX electro- magnetic flowmeter for monitoring the delivery rate into the well houses. And for good reason: because, compared to conventional mechanical Waltman meters, OPTIFLUX offers key advantages. There is the significantly lower pressure loss, for example, which has a positive effect on the power consumption of the pumps. Or the longer service life, due...
Open the catalog to page 10The pressure filter system - The heart of water treatment The quality of untreated water can vary widely in nature, depending on the extraction point. Therefore around one third of the entire amount of ground filtrate in the waterworks is conducted through a total of nine pressure filter tanks filled with quartz chips for the biological filtering out of manganese. This is where the core process of water treatment takes place. Because, in addition to flocculation, this is where the decision is made as to which suspended particles and colloids are filtered out of the untreated water and in...
Open the catalog to page 1112 Booster pump facility Booster pump works with collector well - Everything under control Maximum system availability is indispensable for a waterworks - whether during water abstraction, water treatment or transport. In the Haltern waterworks, a total of 16 rotary pumps with electric drives take on the task of supplying potable water to the public supply network. The largest pumps can transport 3,500 m3 of water per hour over an elevation of 110 meters. Do different water qualities and flocculating agents also mean different types of devices for measuring the flow? Not necessarily....
Open the catalog to page 12Flocculation system Corrosion protection Finding the right degree In waterworks, the untreated water from all of the vertical wells is consolidated in deep containers. Here, natron base liquor for increasing the ph value and monophosphate are dosed for protecting the pipeline network and home installation from corrosion. Optionally, a chlorine bleaching system can be connected for dosing, to prevent microbiological effects. These dosings require the use of a flowmeter, which stands out on the one hand due to its extraordinary measuring accuracy (±0.15 %) and which is also chemically durable...
Open the catalog to page 15The run-out - Clean and neat Flowmeters in the run-out of the waterworks and in the distribution network work in responsible positions. After all, they measure the potable water intended for the population and must precisely comply with the strict legal regulations. This also affects the selection of the flowmeter and its materials inside the measuring pipe. Thus, only sensors that have liners that are approved as per KTW and DVGW worksheet 270 as well as respective guidelines according to the UBA may be used in Germany. The OPTIFLUX from KROHNE meets these criteria and is the first choice...
Open the catalog to page 16Measuring the chlorine content Many municipal waterworks perform no permanent disinfection of drinking water. However, in many cases a process known as emergency chlorination takes place. The process is switched on in case of need, adding chlorine to the drinking Emergency chlorination is special in that it is only very rarely required, which means that non-chlorinated water usually flows through the measuring systems. Conventional measurement technology is now often faced with the problem of biological fouling covering the membrane, making the sensor inoperative over time. For this reason,...
Open the catalog to page 18All KROHNE Messtechnik GmbH catalogs and technical brochures
-
LDM system Brochure en
28 Pages
-
Product Overview Brochure
84 Pages
-
OPTITEMP TRA/TCA PLUS
72 Pages
-
TIDALFLUX 2300 F
24 Pages
-
OPTISONIC 8300
40 Pages
-
OPTIBAR LC 1010
20 Pages
-
DWM1000/DWM2000
20 Pages
-
DW 181
28 Pages
-
OPTITEMP TRA-H6X/-C6X
36 Pages
-
Flow measurement
72 Pages
-
HYG.Accessories
24 Pages
-
IFC 050 Handbook
84 Pages
-
IFC 050
32 Pages
-
BATCHFLUX 5500 C
28 Pages
-
AFC 030 Converter
32 Pages
-
AMADAS Analyser Management
4 Pages
-
CALSYS for metering
4 Pages
-
Virtual flow computer
4 Pages
-
OPTIMASS 1000 Marine
2 Pages
-
Optimass 2000
2 Pages
-
OPTIMASS 6000 Marine
2 Pages
-
OPTIFLEX 4300 C Marine
2 Pages
-
OPTIWAVE 8300 C Marine
4 Pages
-
Accessories hygienic instruments
12 Pages
-
C95 CI
4 Pages
-
C95 Digital Panel Meter
4 Pages
-
OPTISONIC 6300 P | 6400
2 Pages
-
Inertisation (VA meters)
2 Pages
-
Unconventional Energy Resources
18 Pages
-
Temperature measurement
40 Pages
-
Brochure Food and Beverages
58 Pages
-
Product Overview
64 Pages
-
BM 500
16 Pages
-
H250 M40
48 Pages
-
OPTIFLUX 1000
24 Pages
-
IFC 100
36 Pages
-
H250 M40
20 Pages
-
SMARTPAT Overview
16 Pages
-
WATERFLUX 3070
24 Pages
-
Temperature Catalogue
148 Pages
-
Gas & Steam Product Overview
5 Pages
-
Pressure Product Overview
32 Pages
-
Water & Wastewater
44 Pages
-
Food Applications
100 Pages
-
OPTITEMP TT 51
2 Pages
-
OPTIWAVE 5200
2 Pages
-
OPTIWAVE 6300
2 Pages
-
ALTOSONIC V12 Highlights
18 Pages
-
Energy (Oil & Gas)
44 Pages
-
VISCOLINE
2 Pages
-
OPTISONIC 7300
2 Pages
-
OPTIFLEX 2200
2 Pages
-
BM 26
2 Pages
-
OPTISONIC 3400
16 Pages
-
OPTIMASS 6400
16 Pages
-
MICRO-SET
12 Pages
-
IFC 100 | IFC 300
9 Pages
-
ALTOSONIC V12
18 Pages
-
Brochure Oil & Gas Industry
40 Pages
-
Brochure Energy Measurement
28 Pages
-
Brochure Energy (Oil and Gas)
44 Pages
-
OPTITEMP TR | TC 100
28 Pages
-
IFC 300 Converter
56 Pages
-
DW 18 SERIES
28 Pages
-
Brochure Bioenergy
12 Pages
Archived catalogs
-
Level Product Overview
50 Pages
-
CARGOMASTER
16 Pages
-
SDA Flap-type Flowmeter
2 Pages
-
DWM 1000 | 2000
20 Pages
-
UFM 3030
16 Pages
-
TR TC