Flow Measurement Gear type flow meters
Open the catalog to page 1Gear type flow meters VCA / VCG Construction Function General product characteristics Technical data Electrical connections Signal characteristics Pressure drop charts Technical drawings
Open the catalog to page 3Gear type flow meters VCA / VCG I Construction 1 Housing 2 Cover 3 Gear 4 Plug 5 Sensor 6 Bearing Consisting of two high-precision gears, the measuring unit is driven by the liquid flow based on the displacement principle. The gears run in an almost contactless manner in the measuring chamber. The bearing consists of ball and plain bearings. The measuring principle does not cause any pressure or volume flow pulsation. Because there is no need for settling sections on the inlet and outlet side, machines/ plants can be designed to be more compact. All moving parts are lubricated by the measuring...
Open the catalog to page 4Gear type flow meters VCA / VCG Technical data I General characteristics VCA Nominal sizes Nominal size plate mounting (P) / pipe connection (R) Mounting position Mounting position Flow direction Flow direction Typical measurement accuracy Typical measurement accuracy Maximum permissible pressure loss Maximum permissible pressure loss Ambient temperature Ambient temperature Media temperature Media temperature Sound pressure level Sound pressure level spheroidal cast iron stainless steel / steel ball bearing, plastic plain bearing, multi-layer plain bearing multi-layer plain bearing I Overview...
Open the catalog to page 5Gear type flow meters VCA / VCG 1 Product 2 Nominal size 0.04 0.1 0.2 2 5 3 Bearing K ball bearing (only nominal size 0.04) U plastic plain bearing (only nominal size 0.2) M multi-layer plain bearing 4 Material 4 housing aluminium / gears stainless steel 5 housing aluminium / gears steel 5 Sealing F FKM 6 Surface 3 without coating 4 hard-coated 5 anodized (decorative) 7 Connection type P Plate mounting (only nominal sizes 0.2 and 2) R Pipe connection 8 Sensors 1 1 sensor 2 2 sensors 3 without sensors 4 2 sensors, vibration-proof/condensation-proof 9 Electronic versions (pre-amplifier) S Standard...
Open the catalog to page 6Gear type flow meters VCA / VCG 1 Product 2 Nominal size 2 3 Bearing M multi-layer plain bearing 4 Material 1 housing spheroidal cast iron GJS-400 / gears steel 5 Sealing F FKM 6 Surface 1 standard coating 3 without coating 7 Connection type P plate mounting 8 Sensors 1 1 sensor 2 2 sensors 9 Electronic versions (pre-amplifier) S Standard V without pre-amplifier 10 Electric connection (plug and pre-amplifier housing) H appliance socket (Hirschmann) standard M appliance socket (Hirschmann) with M12x1 4-pole connection V without
Open the catalog to page 7Gear type flow meters VCA / VCG Electronics I Electrical connections Electrical connection VCA – single-channel Electrical connection VCA 0.2/VCG 2 – dual-channel 2: Channel 1 (green) 3: not assigned 2: Channel 1 (green) 3: Channel 2 (yellow) I Electrical characteristics Number of measuring channels 12 ... 30 V DC reverse polarity protected Pulse shape with symmetrical output signal Square duty factor/channel 1:1 +/- 15% Signal output Pulse offset between the two channels (2 sensors) Output power / channel Pa max Protection rating I Signal characteristics The cycle time corresponds to the turnover...
Open the catalog to page 8Gear type flow meters VCA / VCG Pressure drop Parameter: Viscosity in mm²/s I VCA 0.04 ... 0.2 Flow rate Q in l/min Flow rate Q in l/min Flow rate Q in l/min Flow rate Q in l/min Flow rate Q in l/min Flow rate Q in l/min
Open the catalog to page 9Gear type flow meters VCA / VCG Pressure drop Parameter: Viscosity in mm²/s I VCA/VCG 2 and VCA 5 Flow rate Q in l/min Flow rate Q in l/min Flow rate Q in l/min Flow rate Q in l/min
Open the catalog to page 10Gear type flow meters VCA / VCG
Open the catalog to page 11Gear type flow meters VCA / VCG Dimensions I VCA 2 – pipe connection Also available with pipe connection dimension G1.
Open the catalog to page 12Abmessungen VCG 2 FC P2 Gear type flow meters chflusswiderstand VCG 2 Parameter: Viskosität (mm2/s) Durchflusswiderstand VCG 2 Parameter: Viskosität (mm2 Flow resistance VCG 2 Parameter: viscosity (mm2/s) te de charge VCG 2 Paramètre: viscosité (mm2/s) Perte de charge VCG 2 Paramètre: viscosité (mm2/s) hflusswiderstand VCG 2 Parameter: Viskosität (mm2/s) 0 w resistance VCG 2 Parameter: viscosity 20 2/s) (mm 30 0 10 Durchflusswiderstand ∆ p sure drop ∆ p / Perte de charge ∆ p e de charge VCG 2 Paramètre: viscosité Durchfluss / Flow rate / Débit Q Durchflusswiderstand ∆ p Pressure drop ∆ p / Perte...
Open the catalog to page 13Gear type flow meters VCA / VCG
Open the catalog to page 14Gear type flow meters VCA / VCG
Open the catalog to page 15Low and high-pressure gear pumps for lubricating oil, hydraulic, process and test bench applications, fuel and metering systems. I Flow Measurement Gear, turbine and screw type flow meters and electronics for volume and flow, metering and consumption in the chemical industry, hydraulic, process and test bench technology. I Hydraulics Single and multistage high-pressure gear pumps, gear motors and valves for construction machinery, municipal vehicles, agricultural vehicles, special vehicles and truck bodies. I Valves Cetop valves for all requirements stationary and mobile applications. Pressure,...
Open the catalog to page 1618 Pages
10 Pages
12 Pages
16 Pages
30 Pages
12 Pages
14 Pages
9 Pages
28 Pages
36 Pages
12 Pages
22 Pages
12 Pages
12 Pages
16 Pages
12 Pages
16 Pages
16 Pages
40 Pages