Catalog excerpts
Flow Measurement Gear type flow meters
Open the catalog to page 1Gear type flow meters VC Construction Function General product characteristics Approvals Sensor versions General characteristics Accuracy characteristics Typical applications Technical data Electrical connections Signal characteristics Electrical characteristics Explosion-proof version (ATEX/IECEx) Pressure drop charts VC technical drawings overview VC technical drawings (dimensions/weights) Connecting plate technical drawings (dimensions/weights)
Open the catalog to page 3Gear type flow meters VC I Construction 1 Housing 2 Cover 3 Gear 4 Plug 5 Sensor 6 Bearing I General product characteristics • High-precision measurements with excellent repeatability • Maximal measurement resolution if used with encoder • IO-Link technology available • Wide measurement ranges with appropriate design sizes Application-optimised specification Low pressure drop Any flow direction Wide temperature range High working pressure Low noise emission Consisting of two high-precision gears, the measuring unit is driven by the liquid flow based on the displacement principle. The gears...
Open the catalog to page 4Gear type flow meters VC Description I Standard version The standard versions come with an integrated pre-amplifier which converts the pulses from the magnetic sensors into square-wave signals which are then computed by an electronics into specific measurement values. The optionally available remote-electronics version is designed to handle extreme temperature ranges. I Encoder version with maximised measurement resolution Compared with standard sensors, encoders are capable of generating considerably more pulses, thus increasing measurement resolution by orders of magnitude....
Open the catalog to page 5Gear type flow meters VC Technical data I General characteristics Nominal sizes plate mounting (P) / pipe connection (R) Mounting position Flow direction Typical measurement accuracy Maximum pressure Maximum permissible pressure loss Ambient temperature Media temperature Sound pressure level The indicated measurement accuracy refers to the pulse volume, i.e. the percentage variance applies to the latest measurement value. The measurement accuracy tests performed can be traced to DAkkS (Deutsche Akkreditierungsstelle, German Accreditation Body). The measurement accuracy is up to +/- 0.3% of...
Open the catalog to page 6Gear type flow meters VC Technical data I Application examples Specifications (type key ID for bearing and material) Typical media Typical media characteristics Typical application of the flow/ volume measurement Oil Braking fluid Diesel Skydrol lubricating fluids low to medium viscosity Hydraulic systems Test bench construction Cylinder stoke measurement lubricating fluids medium viscosity oil filling (metering systems) offset ink polyol isocyanate glue resin silicone lubricating fluids medium to high viscosity consumption measuring (printing machines) polyol isocyanate glue resin silicone...
Open the catalog to page 7Gear type flow meters VC Technical data I Overview Specifications (type key ID for bearing and material) ball bearing Material: housing ball bearing carbide plain carbide plain ball bearing bearing bearing (high tolerance) hybrid ball bearing ball bearing ball bearing spheroidal stainless steel spheroidal stainless steel spheroidal stainless steel spheroidal cast iron cast iron cast iron cast iron GJS-400-15 1.4404 GJS-400-15 1.4404 GJS-600 GJS-400-15 1.4404 Material: gears aluminium 3.2315 stainless steel 1.4462 Permissible particle size in pumped medium Maximum pressure in bar 480 * See...
Open the catalog to page 8Gear type flow meters VC Technical data I Encoder version resolution Nominal size Sensor resolution* Pulse volume Measured value resolution 4-fold** Pulse frequency with Qmax * More sensor resolutions available on request. ** Resolution with both measuring channels and 4-fold evaluation I Sealing elements and electronics temperature tolerance Versions with integrated electronics Remote-electronics versions Tamb = -60* … 150 °C Version with appliance socket (Hirschmann) Tamb = -40* … 80 °C Electronics version Reduced supply voltage 12 V High temperature ATEX version without preamplifier...
Open the catalog to page 9Gear type flow meters VC Selection guide Medium temperature in °C -60 stainless steel high-temperature PLUS with remote electronics spheroidal cast iron with internal electronics hybrid ball bearing Electronics versions carbide plain bearing Sealing material ball bearing Material: housing ATEX/IECEx high-temperature PLUS I Example: determination of temperature range VC ball bearing spheroidal cast iron Resultant temperature range
Open the catalog to page 10Gear type flow meters VC 1 Product 2 Nominal size 0.025 3 Bearing H hybrid ball bearing C ball bearing, high tolerance G carbide plain bearing 1 housing spheroidal cast iron GJS-400 gears steel 2 housing stainless steel gears stainless steel 3 housing spheroidal cast iron GJS-600 gears steel 4 housing aluminium (only nominal size 0.2) 3 without coating R pipe connection 8 Sensors 2 2 sensors 1 1 sensor 3 without sensors 4 2 sensors vibration-proof/condensation-proof 5 encoder only nominal sizes 0.01 · 0.04 · 0.2 · 1 9 Electronic versions (pre-amplifier) S standard H high-temperature K...
Open the catalog to page 11Gear type flow meters VC Electronics I Electric connections Standard and high-temperature version High-temperature PLUS and low-temperature version Connection plug arrangement (M12x1 4-pole round connector) 3: Channel 2 (yellow) 4: 0 Volt (white) Encoder version 3: 0 Volt (blue) 4: Channel 2 (black) Cannon version Connection plug arrangement (M12x1 metal/4-pole round connector) Connection plug arrangement A: UB (brown) B: Channel 1 (green) C: Channel 2 (yellow) D: 0 Volt (white) IO-Link version Connection plug arrangement (M12x1 metal/4-pole round connector) IO-Link mode 1: brown 2 I Signal...
Open the catalog to page 12Gear type flow meters VC Electronics I Standard versions electrical characteristics Number of measuring channels 24 V +/- 20% or 12 V +/- 20% for versions with reduced supply voltage Pulse shape with symmetrical output signal Square wave, duty factor/channel 1:1 ± 15% Signal output Pulse offset between the two channels Output power / channel Pa max Protection rating I Encoder versions electrical characteristics Number of measuring channels Pulse shape with symmetrical output signal Square wave, duty factor/channel 1:1 ± 15% Signal output Pulse offset between both channels Maximum load Power...
Open the catalog to page 13All KRACHT GmbH catalogs and technical brochures
-
Hydraulic cylinder CNL
18 Pages
-
High pressure gear motors KM 5
10 Pages
-
High pressure gear motors KM 3
12 Pages
-
High pressure gear motors KM 2
16 Pages
-
High pressure gear motors KM 1
30 Pages
-
Pressure relief valves DBD
12 Pages
-
Pressure valves DV
14 Pages
-
Turbine flow meters TM
9 Pages
-
Screw type flow meters SVC
28 Pages
-
Gear type flow meters VCA / VCG
16 Pages
-
High pressure gear pump KP 5
12 Pages
-
High pressure gear pumps KP 1
22 Pages
-
High pressure gear pumps KP 0
12 Pages
-
Gear pumps DT DuroTec
12 Pages
-
Gear pumps KP 1 DuroTec
16 Pages
-
Gear metering pumps ADP
12 Pages
-
Gear pumps BT/BTH
16 Pages
-
Gear pumps KF 730 ... 1500
16 Pages
-
Gear pumps KF 2.5 ... 630
40 Pages