GB-Y CT50N1/5N31 YMB051-Y DIECAST CLAMPING SYSTEM
Open the catalog to page 1The main requirements for proper operation of a die-casting machine/magnesium mold clamp are: (1) high temperature proof (due to the extreme high temperature during molding) and (2) resistance to stains and spattering molten metal (a cause of most malfunctions due to the lubricant wold releasing agent in the movable part of the clamp).To ensure these qualities (avoid these influence), KOSMEK incorporates its extensive knowhow in clamps for thermal forging presses and plastic molding equipment. Stationary platen clamp Movable platen clamp Operation control panel Hydraulic unit of clamp...
Open the catalog to page 2CLAMP p3 GB0400-Y 32.3 39.2 GB0630-Y 50.0 61.7 GB1000-Y 93.1 98.0 GB1600-Y 137 157 Select the proper system in consultation with the sales representative considering requirements such as: Machine capacity Injection molding conditions Mold specifications The KOSMEK's clamp system consists of the following components Main components Mold opening force = Mold closing force of machine x 10% = 3500 x 0.1 = 350 Therefor it can be assumed that the mold opening force is 350 kN. Required clamping force = Mold opening force Number of clamps = 350 4 = 87.5 98.0 According to the table above (clamp...
Open the catalog to page 3Model GB0400-Y GB0630-Y GB1000-Y GB1600-Y MIN.E 67.5 81 108 130 F 86 106 119 139 G 40 50 55 60 J 23 30 30 30 K 107.5 132 161 201 L 130.5 162 191 231 M (h) 34.5 (30 35) 39.5 (37.5 47.5) 54 (50 60) 71 (55 65) 39.5 (25 30) 49.5 (27. 37.5) 64 (40 50) 81 (45 55) N 10 11.5 11.5 12.5 P 16 20 20 20 R 51.5 49 68 73 S 56 69 95 116 MIN.C 12 14 16.5 20 Rc 1/4 1/4 1/4 1/4 MAX.h 50 60 70 80 c d b a GB 063 0 DJL Y SER.No. 39.2 18 61.7 17.5 22 98.0 32.5 24 157 48.1 28 GB0400-Y GB0630-Y GB1000-Y GB1600-Y 8 4 4 7 3.5 3.5 9.7 27.0 36.8 24.5 42 54 32.3 50.0 93.1 137 L K N S J M h 37 F G C D E The GB-Y clamp is...
Open the catalog to page 4Model GB0400-MY Model GB0630-MY GB1000-MY GB1600-MY GB0400-Y GB0630-Y GB1000-Y GB1600-Y 32.0 39.0 45.0 57.0 L (mm) D E H J L M N T h=20 32 27 23 23 23 23 23 20 6 36 27 31 31 27 27 23 10 36 42 47 36 36 23 10 50 55 45 45 23 10 h=25 h=30 h=35 h=40 h=45 h=50 G J FEATURES OF GB-Y TYPE CLAMP DESCRIPTION OF OPTION MINIMUM DIMENSION TABLE OF MOLD CLAMP Protective cover The lubrication and dust in the molding process causes particles to solidify and obstruct moving parts which corrode the sliding surfaces thus shortening the useful life of the mechanism. The protective cover prevents fixation of...
Open the catalog to page 5YMB operation control panel 12.6mm2(P A) 52.8mm2(A@R) CT unit OPERATION CONTROL PANEL UNIT INTERLOCK INPUT AND OUTPUT MODEL AC200V (AC200`240V) 50/60kHz 1.0A DC24V 0.5A 24.5 36.8 1920 DC24V 22.5 0.41MPa JF1030-0 BA5S11-0 1/62.5 JB2800-M0 JB4000-M0 BR5N11-0 24.5 MPa 40/40MPa 40/40MPa GB0400-Y CT50N1-USUSUS-5G- CT5N31-USUSUS-5GGB0630/ GB1000/GB1600-Y G Q N 2.45 @0 AB7000-G AD7300-G 1.30 /min 3.50 /min Model Working Pressure (MPa) Max Rated Pressure (MPa) Tank Nominal Capacity (cm3) Working Capacity: HL - HL (cm3) Control Voltage Working Temperature (Peripheral Temperature of Unit) Operation...
Open the catalog to page 6Rc1/4 2- 28 A port 3-Rc1/4 HDLD3820cm3 LDLD1900cm3 102 100 100 32 380 370 33 3 15 360 389 14 A1 A2 A3 42 80 84 41 205 59 117 Stand 505 577 805 150 100 78 36 195 150 36 78 185 570 (574) (389) (211) ‚e‚k ‚e‚k ‚e‚k 14.1 hole 45 (815) QUICK MOLD CHANGE SYSTEM CONTROL PANEL I.M.M CONDITIONS MOLD OPEN OK MOLD CHENGE MOVABLE PLATEN CLAMP ALARM RESET STATIONARY PLATEN MOLD CLOSE OK MOLD CLOSE COMPLETED (G) (G) (G) (G) (G) (R) (R) (R) (R) (G) OFF ON LOCK LOCK RELEASE HIGH PRESSURE ALARM RELEASE POWER MOLD CLOSE COMPLETED BYPASS i‚xj 120 235 80 ACRYLIC COVER 50 170 112 50 25 2- 7 30 70 30 80 380 100...
Open the catalog to page 7CAT.NO.DQ-02-01 Printed in Japan 2003. 2. First 1C http://www.kosmek.co.jp HEAD OFFICE : 1-5, 2-CHOME, MUROTANI, NISHI-KU, KOBE 651-2241 TEL.81-78-991-5115 FAX.81-78 -991-8787 BRANCH OFFICE : KOSMEK(U.S.A.) LTD. 9824 S. INDUSTRIAL DRIVE SUITE B.BRIDGEVIEW, ILLINOIS 60455, U.S.A. TEL.708-598-5772 FAX.708-598-6215 QUICK DIE CHANGE SYSTEMS Die replacimg systems for stamping presses.
Open the catalog to page 8All KOSMEK catalogs and technical brochures
-
A Pneumatic Hole Clamp Model SWA
30 Pages
-
Expansion locating pin VRA
12 Pages
-
Hole Clamp SFA
34 Pages
Archived catalogs
-
Hydraulic Unit CB - CC - CP - CS
20 Pages
-
Positioning Pin
8 Pages
-
Quick Die Change System GA
28 Pages
-
Hole Clamp FE
32 Pages