Overview: The document details the Konica Minolta Illuminance Meter series, including models T-10A, T-10MA, T-10WSA, and T-10WLA, designed for measuring illuminance and compatible with PWM-controlled light sources.
Specifications: These meters conform to JIS AA Class and DIN Class B standards, featuring a silicon photocell receptor, auto-ranging capabilities, and a user calibration function. They support multi-point measurements (2 to 30 points) with a range from 0.01 to 299,900 lx.
Design and Accessories: The meters have detachable receptor heads for flexible use in narrow spaces. Accessories include AA batteries, straps, cases, and optional data management software for Excel® integration.
Applications: Suitable for general illumination, PWM-controlled lighting, and outdoor measurements, these meters are used in research, inspection, and maintenance across various industries.
Key Features: The meters handle PWM-controlled lighting, are compatible with next-generation light sources, and are easy to use in multi-point systems. The T-10WSA and T-10WLA models are waterproof for outdoor and fishery applications.
Safety and Compliance: Users should read the instruction manual for safe operation. The devices are ISO certified, ensuring quality in design, development, and manufacturing.
Procedures and Usage: Powered by 2 AA batteries or an AC adapter, the device operates within -10 to 40°C and up to 85% humidity. It supports PWM-controlled sources and multi-point measurements.
Norms and Standards: Conforms to JIS AA Class and DIN Class B. The mini receptor model is waterproof for outdoor use.
Recommendations and Safety Precautions: Users should follow the manual, use specified power supplies, and ensure cable stability during measurements. ISO certifications cover design, development, manufacture, and service.
Additional Information: Notes on mini receptors emphasize cable security during measurements. Contact information for Konica Minolta's global network is provided.
See more

Catalog excerpts

Illuminance Meter T-10A-1

KONICA MINOLTA Compatible with PWM-controlled sources Illuminance Meter KONICA MINOLTA Can be used for simple, inexpensive multi-point measurements. Mini receptor model also available to enable illuminance measurements even in narrow spaces. KONICA MINOLTA The Standard in Measuring Color&Light Giving Shape to Ideas

 Open the catalog to page 1
Illuminance Meter T-10A-2

For simple but accurate illuminance measurements. Makes creating illuminance measurement systems such as multi-point measurement systems easy! Reliable, worry-free illuminance meters that conform to JIS AA Class and DIN Class B Compatible with PWM-controlled lighting. Enables measurements of next-generation light sources. Illuminance Meters T-10A and T-10MA conform to Class AA of JIS C 1609-1: 2006 "Illuminance meters Part 1: General measuring instruments" and DIN 5032 Part 7 Class-B " Photometry; classification of illuminance meters and luminance meters" requirements to provide high-accuracy,...

 Open the catalog to page 2
Illuminance Meter T-10A-3

ch as multi-point measurement systems easy! Konica Minolta's line of instruments for measuring illuminance includes not only the Illuminance Meter T-10A which can measure PWM-controlled light sources, but also the Chroma Meter CL-200A which can measure color temperature and the Illuminance Spectrophotometer CL-500A which can measure color-rendering properties. Convenient, easy-to-use Excel® add-in software Reads measurement data from T-10A series Illuminance Meters directly into Excel®. Further processing of data can then be performed easily using the various functions of Excel®. Main specifications...

 Open the catalog to page 3
Illuminance Meter T-10A-4

System Diagram Additional receptors (sold separately; Product includes 1 receptor according to model purchased) Data management using computer PC (commercially available) Data Management Software For multi-point and cable extension measurement Adapter Unit for Receptor Head Receptor Head RS-232C printer (commercially available) Adapter Unit for Main Body Custom order Data recording using printer Case T-10MA Receptor Head T-10WSA Receptor Head T-10WLA Receptor Head With LAN category 5 cable; 1m Example of cable extension Printer Cable T-A12 LAN (10 BASE-T) category 5 straight cable (commercially...

 Open the catalog to page 4

All Konica Minolta catalogs and technical brochures

  1. Leather

    8  Pages

  2. Glass

    12  Pages

  3. CL-500A

    4  Pages

  4. CL-200A

    4  Pages

  5. CA2500

    8  Pages

  6. Rhopoint IQ-S

    8  Pages

  7. Alcohol

    8  Pages

  8. Cosmetics

    8  Pages

  9. CM-23d

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.