Group: Sensing Europe B.V.
Catalog excerpts
KONICA MINOLTA CS-3000 SERIES Provide the same precision and reliability of past Konica Minolta spectroradiometer models with significantly faster operation and support for automation. The Standard in Measuring Color & Light '' * » * *« r * , Giving Shape to Ideas
Open the catalog to page 1Top-of-the-range spectroradiometer models that bring the latest digital technology together with Konica Minolta’s long track record of sensor technology. High precision CS-3000 Series models continue the tradition of outstanding optical design and signal processing technology of past models while providing the high precision needed for standard value measurement of displays and many other light sources. Even at low luminance levels, they enable precise noise-suppressed measurement over the entire measurement wavelength range with half width values of 5 nm or less as recommended by CIE (CIE...
Open the catalog to page 2Equipped with high-speed CPU Enables command-based measurement in as little as 0.041 second per measurement (Under Konica Minolta conditions, with integration time set to 0.005 second) New color display design reduces impact on darkroom environment * Equipped with function for turning display OFF during measurement RS-232C communication at up to 921,600 bps Supports long cable connection and Bluetooth adapter* attachment * Sold separately; adapter powered via RS-232C connector USB 2.0 communication Virtual COM port connection enables operating system-independent connection (Windows, Mac or...
Open the catalog to page 3Accessories for various applications; standard software* ND filters CS-A40 (1/10) and CS-A41 (1/100) Externally mounted ND filters that come with calibration data. Used when measuring high luminance levels not supported by the built-in ND filter alone. Two types with different densities are available. An adapter that attaches to the lens unit to enable spectral irradiance measurement with a spectrum wavelength width of 5 nm or less, and accuracy conforming to Class AA general illuminance meter of JIS C 1609-1: 2006 (Illuminance Meters Part 1: General Measuring Instruments). The measurement...
Open the catalog to page 4The standard software can be downloaded free of charge from the Konica Minolta website. Software downloads require input of customer information. Software for Spectroradiometer CS-S30 Software enabling CS-3000 Series models to perform computer-controlled measurement. Easy-to-read screen displays enable intuitive operation. Can be downloaded from the link below. https://www.konicaminolta.com/instruments/ download/software/display/index.html <Features> Compatible with both Windows and Mac operating systems. Can set and execute a number of different measurement functions, and display graphs of...
Open the catalog to page 5Series lineup The CS-3000 Series consists of three models—the flagship CS-3000 HDR, standard CS-3000 and cost-performance CS-2000 Plus. The cost-performance model is an enhanced version of the CS-2000 model in the previous lineup. It adds a high-speed computational CPU and the Intelligent Dark function—a new algorithm that eliminates the need for dark value measurement without sacrificing accuracy or measurement time. Measurement wavelength range Wavelength resolution Display wavelength interval Wavelength precision Spectrum wavelength width Measurement angle Minimum measurement diameter...
Open the catalog to page 6*1: Average value of 10 measurements in Normal mode, at temperature of 23°C ± 2°C and maximum relative humidity of 65%. *2: For 10 measurements in Normal mode, at temperature of 23°C ± 2°C and maximum relative humidity of 65%. *3: Measurement time during USB cable-based communication with PC. Excludes time needed during measurement for shutter open/close operation and displaying results on LCD screen. * For items without conditions expressly indicated below, the standard Konica Minolta conditions apply. ±0.3 nm (center-of-gravity wavelength mercury cadmium lamp: 435.8 nm, 546.1 nm, 643.8...
Open the catalog to page 7System diagram CS-3000HDR CS-3000 CS-2000Plus Spectroradiometer Standard accessory Optional accessory Screw for focus ring lock CS-A38 2-point Calibration Certificate (CS-2000 Plus) 3-point Calibration Certificate (CS-3000 HDR and CS-3000) USB cable (2 m) CS-A32 Lens Cap ND Filter (1/10) CS-A40 (1/100) CS-A41 Calibration Certificate (For ND filter) ND Eyepiece filter (For high luminance) CS-A39 Closeup Lens CS-A42 Calibration Certificate (For closeup lens) Illuminance Adapter CS-A43 Calibration Certificate (For Illuminance Adapter) Software for Spectroradiometer CS-S30 * Downloaded from...
Open the catalog to page 8All Konica Minolta catalogs and technical brochures
-
CR-400/410
5 Pages
-
Spectrophotometer CM-M6
3 Pages
-
cm3630a
3 Pages
-
cm-3700a
3 Pages
-
cm36dg
8 Pages
-
CM-700d
3 Pages
-
Spectrophotometer CM-25cG
3 Pages
-
CM-26dG / CM-26d / CM-25d
5 Pages
-
CM-5
3 Pages
-
CL-500A
4 Pages
-
Multi Gloss 268A
4 Pages
-
Solution_Alcohol_2024
8 Pages
-
Solution_Automotive General_2024
20 Pages
-
Solution_Paint Coating
12 Pages
-
Cosmetics_2024
8 Pages
-
Rhopoint TAMS™
12 Pages
-
KMSEU_Solution_Plastics_2024
12 Pages
-
t10a_catalog
4 Pages
-
CA2500
8 Pages
-
CM-23d
2 Pages
-
Spectrophotometer CM-3700A
4 Pages
-
CM-3630
4 Pages
-
CA-2500
2 Pages
-
CL-200A
5 Pages
-
T-10A
6 Pages
-
Rhopoint iQ
4 Pages
-
SpectraMagic™NX
6 Pages
-
CR-10Plus
2 Pages
-
CS-2000A
6 Pages
-
FD-9
4 Pages
-
Gloss-Meter Rhopoint FLEX
2 Pages