Group: Sensing Europe B.V.
Catalog excerpts
Illumination/ viewing system Reflectance d: 0° (diffused illumination, 0-degree viewing) Integrating sphere ø 152 mm (6 inch) Detector Silicon photodiode array (dual 40 elements) Spectral separation device Computer (commercially available) Half bandwidth Wavelength range 360 nm – 740 nm Wavelength pitch Light source Pulsed xenon lamp ×3 Illumination area Reflectance range 0 to 200%; Display resolution: 0.01% LAV:ø 34 mm; MAV:ø 11 mm Measurement area LAV:ø 30 mm; MAV:ø 8 mm *2 White Calibration Plate CM-A284 Measurement time Within 1.5 sec Minimum measurement interval Within 2 sec (UV 100% measurement) Within 3 sec (UV 0%/UV adjusted measurement) Colorimetric values Standard deviation within ΔE*ab : 0.02 (White Calibration Plate) Spectral reflectance Standard deviation within 0.1% : (hen a white calibration plate is measured 30 times at 10-second intervals after white calibration) Inter-instrument agreement Within ΔE*ab 0.2 (Based on average for 12 BCRA Series II color tiles; compared to values measured with a master body under Konica Minolta standard measurement conditions) 100% / 0% / Adjusted (Instantaneous numerical adjustment of UV with no mechanical filter movement required); 400 nm and 420 nm UV cutoff filters Applicable standards LAV measurements conform to ISO 2469, JIS P8148, DIN 53145-1 and DIN 53145-2 standards. Viewfinder function Using built-in camera; Software (not included) required. Operating temperature/ humidity range Temperature: 13 to 33°C, Relative humidity: 80% or less (at 33°C) with no condensation Storage Temperature/ humidity rang Temperature: 0 to 40°C, Relative humidity: 80% or less (at 35°C) with no condensation Size (W×H×D) *Accessories 1 - 3 are stored in the accessory case. Standard accessories Optional Konica Minolta (CHINA) Investment Ltd. Konica Minolta Sensing Singapore Pte. Ltd. Konica Minolta Sensing Korea Co., Ltd. ISO Certifications of KONICA MINOLTA, Inc., Sakai Site JQA-QMA15888 Design, development, manufacture/ manufacturing management, calibration, and service of measuring instruments JQA-E-80027 Design, development, manufacture, service and sales of measuring instruments PHONE: (888)473-2656 (in USA), +1(201)236-4300 (outside USA) FAX: +1(201)785-2480 E-Mail: service.sus@konicaminolta.com Nieuwegein, Netherlands PHONE: +31(0)30 248-1193 E-Mail: info.benelux@seu.konicaminolta.eu München, Germany PHONE: +49(0)89 4357 156 0 E-Mail: info.germany@seu.konicaminolta.eu Roissy CDG Cedex, France PHONE: +33(0)1 80 11 10 70 E-Mail: info.france@seu.konicaminolta.eu Warrington, United Kingdom PHONE: +44(0)1925 467300 E-Mail: info.uk@seu.konicaminolta.eu Cinisello Balsamo, Italy PHONE: +39 02849488.00 E-Mail: info.italy@seu.konicaminolta.eu Dietikon, Switzerland PHONE: +41(0)43 322-9800 E-Mail: info.switzerland@seu.konicaminolta.eu VÄSTRA FRÖLUNDA, Sweden PHONE: +46(0)31 7099464 E-Mail: info.nordic@seu.konicaminolta.eu Wrocław, Poland PHONE: +48(0)71 73452-11 E-Mail: info.poland@seu.konicaminolta.eu Istanblul, Turkey PHONE: +90(0)216-528 56 56 E-Mail: info.sensing@konicaminolta.com.tr Shanghai, China PHONE: +86-(0)21-6057-1089 E-Mail: hcn_sensing@gcp.konicaminolta.com Beijing, China PHONE: +86-(0)10-8522 1551 E-Mail: hcn_sensing@gcp.konicaminolta.com Guangzhou, China PHONE: +86-(0)20-3826 4220 E-Mail: hcn_sensing@gcp.konicaminolta.com Chongqing, China PHONE: +86-(0)23-6773 4988 E-Mail: hcn_sensing@gcp.konicaminolta.com Shandong, China PHONE: +86-(0)532-8079 1871 E-Mail: hcn_sensing@gcp.konicaminolta.com Hubei, China PHONE: +86-(0)27-8544 9942 E-Mail: hcn_sensing@gcp.konicaminolta.com Shenzhen, China PHONE: +86-(0)755-2868 7535 E-Mail: hcn_sensing@gcp.konicaminolta.com PHONE: +65 6563-5533 E-Mail: se-service.sg@konicaminolta.com Goyang-si, Korea PHONE: +82(0)2-523-9726 FAX: +82(0)31-995-6511 Cheonan-si, Korea PHONE: +82(0)41-556-9726 Addresses and telephone/fax numbers and e-mail address are subject to change without notice. For the latest contact information, please refer to KONICA MINOLTA Worldwide Offices web page: For correct use and for your safety, be sure to read the instruction manual before using the instrument. • Be sure to use the specified power supply voltage. Improper connection may cause a fire or electric shock. Osaka, Japan New Jersey, U.S.A. European HQ/ BENELUX German Office French Office UK Office Italian Office Swiss Office Nordic Office Polish Office Turkish Office SE Sales Division Beijing Office Guangzhou Office Chongqing Office Qingdao Office Wuhan Office Shenzhen Office Singapore Korean HQ / Kintex Cheonan Office SAFETY PRECAUTIONS KONICA MINOLTA, INC. Konica Minolta Sensing Americas, Inc. Konica Minolta Sensing Europe B.V. State-of-the art ISO-Standard compliant measuring device for the pulp & paper industry with unrivaled preci
Open the catalog to page 1Spectrophotometer CM-3630A Compatibility with the former CM-3630 The long-time standard model in the paper manufacturing industry, the CM-3630, has been rethinked anew and its functionality enhanced - this means that all users of the old CM-3630 can use their historical measurement data without transition problems. Improved functionality Highly competitive markets, such as the paper, pulp and cellulose industry, require a commitment to top quality throughout. With Konica Minolta's state-of-the-art Spectrophotometer CM-3630A and the dedicated Paper-production control software PaperManager...
Open the catalog to page 2System Diagram Illumination/ viewing system Integrating sphere Detector Spectral separation device Wavelength range Wavelength pitch Half bandwidth Reflectance range Light source Illumination area Measurement area Measurement time Minimum measurement interval Repeatability Inter-instrument agreement UV setting Applicable standards CM-3630A Reflectance d: 0° (diffused illumination, 0-degree viewing) 0 152 mm (6 inch) Silicon photodiode array (dual 40 elements) Diffraction grating 360 nm - 740 nm 10 nm Approx. 10 nm 0 to 200%; Display resolution: 0.01% Pulsed xenon lamp *3 LAV: 0 34 mm; MAV:...
Open the catalog to page 3All Konica Minolta catalogs and technical brochures
-
CS-3000
8 Pages
-
CR-400/410
5 Pages
-
Spectrophotometer CM-M6
3 Pages
-
cm-3700a
3 Pages
-
cm36dg
8 Pages
-
CM-700d
3 Pages
-
Spectrophotometer CM-25cG
3 Pages
-
CM-26dG / CM-26d / CM-25d
5 Pages
-
CM-5
3 Pages
-
CL-500A
4 Pages
-
Multi Gloss 268A
4 Pages
-
Solution_Alcohol_2024
8 Pages
-
Solution_Automotive General_2024
20 Pages
-
Solution_Paint Coating
12 Pages
-
Cosmetics_2024
8 Pages
-
Rhopoint TAMS™
12 Pages
-
KMSEU_Solution_Plastics_2024
12 Pages
-
t10a_catalog
4 Pages
-
CA2500
8 Pages
-
CM-23d
2 Pages
-
Spectrophotometer CM-3700A
4 Pages
-
CM-3630
4 Pages
-
CA-2500
2 Pages
-
CL-200A
5 Pages
-
T-10A
6 Pages
-
Rhopoint iQ
4 Pages
-
SpectraMagic™NX
6 Pages
-
CR-10Plus
2 Pages
-
CS-2000A
6 Pages
-
FD-9
4 Pages
-
Gloss-Meter Rhopoint FLEX
2 Pages