Introduction
The document introduces the Konica Minolta FD-7 and FD-5 spectrodensitometers, state-of-the-art devices designed to measure color, density, and light. These devices are particularly notable for their ability to account for the impact of fluorescent whitening agents in paper by using Konica Minolta’s VFS technology, which considers the actual amount of UV in the viewing environment.
Specifications
The FD-7 and FD-5 conform to ISO 13655:2009 measurement mode M1, allowing for UV calibration with any light source. They offer a close correlation between visual evaluation and measurement, enhancing color matching capabilities. The devices are lightweight, with the main body weighing approximately 350g, and are equipped with a concave grating spectral separation device covering a wavelength range of 380 to 730 nm.
Features
The spectrodensitometers provide standalone, scanning, and light measurement functionalities. They can measure illuminance, color temperature, and ∆uv, displaying these values on an internal screen. The devices also perform automatic wavelength accuracy evaluations and temperature drift corrections to ensure precision and stability.
Measurement Capabilities
The devices support various measurement conditions corresponding to ISO 13655, including M0, M1, and M2. They can measure a range of illuminants and observers, and provide data in multiple color spaces and color-difference equations. The measurement range includes density from 0.0D to 2.5D and reflectance from 0 to 150%.
Accessories and Software
Standard accessories include a protection glass, USB cable, white calibration plate, target mask, ruler, illuminance adapter, soft case, and AC adapter. Optional PC software is available for enhanced functionality.
Safety and Usage
Users are advised to read the instruction manual for safe operation. The devices should be connected to the specified power supply voltage to prevent fire or electric shock.
Contact Information
Contact details for Konica Minolta offices worldwide are provided for customer support and inquiries.
See more

Catalog excerpts

Spectrodensitometers FD-7 / FD-5-1

KONICA MINOLTA State of the Art measurement device to measure Colour, Density and Light Giving Shape

 Open the catalog to page 1
Spectrodensitometers FD-7 / FD-5-2

FD-7/FD-5 Ultralight Spectrodensitometer the perfect instrument for conventional and digital printing and packaging applications For the first time UV calibration in accordance with to ISO 13655 M1 The new Konica Minolta FD Spectrodensitometers conform to measurement mode M1 of ISO 13655:2009. In addition to ISO measurement modes M0, M1, M2 and M3, the patented virtual UV calibration allows the use of any light source for the measurements. Close correlation with visual evaluation The impact of fluorescent whitening agents in papers depends on the amount of UV in the viewing environment. Until...

 Open the catalog to page 2
Spectrodensitometers FD-7 / FD-5-3

Spectrodensitometer We take all possible steps to ensure the accurracy of your instrument With conventional measurement devices it is necessary to regularly correct for wavelength shifts. Historically this could only be done by the maker of the instrument. The models FD-5 and FD-7 perform an evaluation of the wavelength accuracy and if necessary a shift compensation with every white calibration. Thanks to the additional correction of temperature drifts you are assured that you are using a precise and stable instrument between maintenance checks. Some choose not to talk about these problems, we...

 Open the catalog to page 3
Spectrodensitometers FD-7 / FD-5-4

Model Spectrodensitometer FD-7 FD-5 Illumination/viewing system 45°a: 0°(annular illumination) 1 Conforms to CIE No. 15, ISO 7724/1, DIN5033 Teil 7, ASTM E 1164, and JIS Z 8722 Condition a for reflectance measurements* Spectral separation device Concave grating Wavelength range Spectral reflectance: 380 to 730 nm; Spectral irradiance: 360 to 730 nm Wavelength pitch 10 nm Half bandwidth Approx. 10 nm Measurement area Ø3.5mm Light source LED Measurement range Density: 0.0D to 2.5D; Reflectance: 0 to 150% Short-term repeatability Density: σ0.01D Colorimetric: Within σΔE00 0.05 (When white plate...

 Open the catalog to page 4

All Konica Minolta Sensing catalogs and technical brochures

  1. ProMetric® I

    2  Pages

  2. CM-512m3A

    3  Pages

  3. CM-M6

    4  Pages

  4. CM-25cG

    5  Pages

  5. FD-7 and FD-5

    6  Pages

  6. CA-410

    8  Pages

  7. AK series

    4  Pages

  8. CM-3700A

    4  Pages

  9. CR-10 PLUS

    2  Pages

  10. CL-200A

    5  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.