VIVID 9i
8Pages

{{requestButtons}}

Catalog excerpts

VIVID 9i - 1

MIMItD NON - CONTACT 3D DIGITIZER konica minolta VI VIO «6 Introducing the latest addition to Konica Minolta's VIVID Sries. Featuring improved accuracy and usability and flexibility. Offering unprecedented value. It's the most advanced model for industrial applications from reverse engineering to design vrification and dimensional inspection. The essentials of imaging

Open the catalog to page 1
VIVID 9i - 2

CAM CAT CAE 2 CAD data Delivery Interference check, simulation Prototype evaluation Evaluation offirst-article parts, Die approval Inspection of mass-produced parts Evaluation/modification of approved model Conversion of physical model to digital format (CAD model) Introducing the VIVID 9i non-contact 3D digitizer. This innovative device is ideal for reverse engineering, design verification, quality inspection, and other industrial applications. The VIVID 9i non-contact 3D digitizer provides high-speed and high-accuracy 3D measurement of dies, cast and forged products, and stamped and...

Open the catalog to page 2
VIVID 9i - 3

1 2 TELE f=25mm MIDDLE f=14mm WIDE f=8mm VIVID 9i system Measurement with VIVID 9i Scanning the target with a laser beam Merging and editing of 3D data Measure targets of any size. Konica Minolta employed its expertise in optical engineering to develop interchangeable highperformance, dedicated lenses. As a result, TELE, MIDDLE and WIDE lenses can be selected to accommodate the size of the measurement target. (Input range in X, Y and Z directions: 93 x 69 x 26 mm to 1495 x 1121 x 1750 mm) Point & Shoot, Leave detailed settings to the 9i. Konica Minolta's AF/AE technology, developed through...

Open the catalog to page 3
VIVID 9i - 4

1 2 VIVID 9i Measuring area Positions of digital camera photos 3D data of reference markers Scale bar Reference marker Coded marker PSC-1 Photographing scenario Capture the image with a digital camera Automatic alignment and merging of 3D data Now it’s time to scan the surface detail using the 9i. As each VIVID 9i scan is captured, it is automatically aligned to the PSC-1 data cloud created in step 1. The VIVID 9i reads the target data and places the scans in their correct orientation. Even relatively smooth shapes such as fenders or door skins are accurately aligned because the alignment...

Open the catalog to page 4
VIVID 9i - 5

Inspection Reverse engineering ..Instrument panel ..Engine valve cover ..Bumper Early detection of shape problems Evaluation at cross section Cross section/Grid display/Diagram dimensions/ Scanning the sample Example of inspection evaluation report Example of CAT work procedure -Comparison inspection between measured Measured data (polygon) Importing Measurement, alignment, merging, and cleaning -Comparison between reference CAD (NURBS) Unnecessary when the automatic surface creation function is used Example of procedure for CAD data creation -Creation of a CAD Model of an Example of...

Open the catalog to page 5
VIVID 9i - 6

http: //se.konicaminolta.us/3d Digital Process Re-engineering Errors at specific points and CAD data- CAD data Alignment with CAD data Color map calculation and measured data- Comparison between CAD data and measured data Inspection evaluation report Color map display providing at-a-glance indication of sections within/outside the tolerance range (contour display) automotive aluminum casting - Example of continuous surface evaluation using environment mapping NURBS Trimmed NURBS surfaces High-continuity surface data patch matching the curve boundaries 3D CAD IGES The application examples...

Open the catalog to page 6
VIVID 9i - 7

The VIVID 9i is based on the principal of laser triangulation. A target is scanned with laser stripes . The CCD camera receives the light reflected from the surface of the subject. Surface shape measurements of the subject are obtained through triangulation, and converted into a 3D polygon mesh. The VIVID 9i measures 640 x 480 points with one scan, simultaneously acquiring surface shape data and color image data. Galvanometer - driven mirror Light-receiving lens system (Interchangeable) Target Light-emitting lens system Laser beam CCD Set of filters (R, G, B, BP, rotatable) VIVID 9i System...

Open the catalog to page 7
VIVID 9i - 8

©2004 KONICA MINOLTA SENSING, INC. 9242-4892-11 AGMCPK Printed in Japan 4 SAFETY PRECAUTIONS Read all safety and operating instructions before operating the VIVID 9i. Use only a power source of the specified rating. Improper connection may cause a fire or electric shock. Do not stare into the laser beam. (MAX. 30mW 690nm / CLASS 1 (FDA), CLASS 2 (IEC) LASER PRODUCT) Type Non-contact 3D digitizer Measuring Method Triangulation light block method Light-Receiving Lenses (Interchangeable) TELE Focal distance f=25 mm MIDDLE Focal distance f=14 mm WIDE Focal distance f=8 mm Scan Range 0.6 to 1.0...

Open the catalog to page 8

All Konica Minolta Sensing Americas catalogs and technical brochures

  1. Light Meters

    24 Pages

  2. GTI GLE-M

    2 Pages

  3. BC-10 Plus

    4 Pages

  4. CR-410PB

    4 Pages

  5. CR-400/410

    5 Pages

  6. CM-3700A

    3 Pages

  7. cm3600a

    3 Pages

  8. CM-2500c

    4 Pages

  9. CM-2600d

    8 Pages

  10. CM-700d/600d

    3 Pages

  11. cm-25cg

    2 Pages

  12. cm-m6

    2 Pages

  13. DTS140 NVIS

    6 Pages

  14. LumiCam 2400

    4 Pages

  15. Light Meters

    24 Pages

  16. CM-25cG

    4 Pages

  17. FD-9

    6 Pages

  18. Colibri®

    6 Pages

  19. CL-70F

    2 Pages

  20. CR-20

    2 Pages

  21. CR-10 Plus

    2 Pages

  22. LCS IV

    1 Pages

  23. CM-512m3

    3 Pages

  24. ISP40

    4 Pages

  25. LGS 1000

    4 Pages

  26. LGS 350

    8 Pages

  27. ISP 500

    4 Pages

  28. ISP 2000

    2 Pages

  29. ISP 150L

    2 Pages

  30. ISP 1000

    4 Pages

  31. LED-81X/-850

    4 Pages

  32. ACS-530

    4 Pages

  33. LED 25

    4 Pages

  34. LSM 350

    4 Pages

  35. LUMICAM 1300

    8 Pages

  36. CAS 140CTS

    4 Pages

  37. CAS 120

    8 Pages

  38. MAS 40

    8 Pages

  39. SPECTRO 320

    12 Pages

  40. COLIBRI

    6 Pages

  41. NC-1

    2 Pages

  42. Light Meters

    11 Pages

  43. light meter

    11 Pages

Archived catalogs

  1. CM-M6

    3 Pages

  2. Pulsox-2

    2 Pages

  3. VIVID 910

    6 Pages

  4. CA-100Plus

    4 Pages

  5. CM-2500c

    4 Pages

  6. CM-3700d

    3 Pages

  7. LCS-III

    4 Pages

  8. CR-400/410

    5 Pages