Spectrophotometers / Portable FD-7
2Pages

{{requestButtons}}

Catalog excerpts

Spectrophotometers / Portable FD-7 - 1

SYSTEM DIAGRAM White Calibration Plate FD-A06 PC software Optional accessory 84.2 3-in-1 next-generation measurement tool Standard accessories only of FD-7 Optional accessories Main specifications Model With removable taget mask attached Illumination/viewing system 45°a: 0°(annular illumination)*1 Conforms to CIE No. 15, ISO 7724/1, DIN5033 Teil 7, ASTM E 1164, and JIS Z 8722 Condition a for reflectance measurements. Spectral separation device Concave grating Wavelength range Spectral reflectance: 380 to 730 nm; Spectral irradiance: 360 to 730 nm Spectral reflectance: 380 to 730 nm Wavelength pitch Half bandwidth Measurement area Light source Measurement range Density: σ0.01D Colorimetric: Within σΔE00 0.05 (When white plate is measured 30 times at 10-second intervals after white calibration has been performed) Within ΔE00 0.3 (Average of 12 BCRA Series II color tiles compared to values measured with a master body under Konica Minolta standard conditions) Short-term repeatability Inter-instrument agreement Measurement time Approx. 1.4 s (single-point reflectance measurement) Colorimetric values, color-difference values, density values, density- Colorimetric values, color-difference values, density values, densitydifference values, dot area ratio, dot gain, PASS/FAIL judgment, difference values, dot area ratio, dot gain, PASS/FAIL judgment illuminance, correlated color temperature Corresponding to ISO 13655 Measurement Conditions M0 (CIE Illuminant A), M1 (CIE Illuminant D50), and M2 (illumination with UV-cut filter); User-defined illuminant Displayed values Measurement conditions Illuminants Observers Color spaces 2° Standard Observer, 10° Standard Observer L*a*b*, L*C*h, Hunter Lab, Yxy, XYZ and color-difference in these color spaces Color-difference equations WI (ASTM E313-96); Tint (ASTM E313-96); ISO Brightness (ISO 2470-1); D65 Brightness (ISO 2470-2); Fluorescence index ISO Status T, ISO Status E, ISO Status A, ISO Status I; DIN16536 Storable data Colorimetric target data: 30 data; Density target data: 30 data Display language English, French, German, Spanish, Japanese, Chinese (Simplified) Scanning measurement of a color chart can be performed. Displayed values; Spectral reflectance data; Spectral irradiance data Displayed values Rechargeable internal lithium-ion battery (Number of measurements per charge: Approx. 2,000 when new); AC adapter; USB bus power 70 × 165 × 83mm (Body only); 90 × 172 × 84mm (With target mask attached) Approx. 350g (Body only); Approx. 430g (With target mask attached) Operating temperature/humidity range 10 to 35°C, 30 to 85% relative humidity with no condensation Storage temperature/humidity range 0 to 45°C, 0 to 85% relative humidity with no condensation *1 Illumination for wavelengths under 400nm is unidirectional. *2 Available when using PC software. SAFETY PRECAUTIONS For correct use and for your safety, be sure to read the instruction manual before using the instrument. Always connect the instrument to the specified power supply voltage. Improper connection may cause a fire or electric shock. • Displays shown are for illustration purpose only. • KONICA MINOLTA and the Konica Minolta logo and the symbol mark, and "The essentials of imaging" are registered trademarks or trademarks of KONICA MINOLTA HOLDINGS, INC. • The basICColor logo is a registered trademark of basICColor GmbH. Certificate No : YKA 0937154 Registration Date : March 3, 1995 Certificate No : JQA-E-80027 Registration Date : March 12, 1997 Streamlines color adjustment in printing, even on substrates with fluorescent whitening agents ©2010 KONICA MINOLTA SENSING, INC.

Open the catalog to page 1
Spectrophotometers / Portable FD-7 - 2

3-in-1 lightweight, handheld spectrodensitometer that measures color, density, and illumination. An ideal instrument for the printing and digital-imaging industries. L*a*b* Color Uniquely corresponds to Measurement Condition M1 of ISO 13655 The world's first M1 type. Konica Minolta's original VFS (Virtual Fluorescence Standard) technology enables L*a*b* measurements corresponding to ISO 13655 Measurement Condition M1 (CIE Illuminant D50). In addition, color measurements corresponding to ISO 13655 Measurement Conditions M0 (CIE Illuminant A) and M2 (illumination with UV-cut filter) can also...

Open the catalog to page 2

All Konica Minolta Sensing Americas catalogs and technical brochures

  1. LumiTop Series

    16 Pages

  2. LumiSuite

    8 Pages

  3. CAS140D_IR

    2 Pages

  4. CAS140CT_IR

    8 Pages

  5. CAS125

    4 Pages

  6. ISP Series

    16 Pages

  7. LGS 650

    8 Pages

  8. LumiCam Series

    16 Pages

  9. CAS 120

    8 Pages

  10. CAS 140D

    16 Pages

  11. GTI GLE-M

    2 Pages

  12. BC-10 Plus

    4 Pages

  13. CR-410PB

    4 Pages

  14. CR-400/410

    5 Pages

  15. CM-3700A

    3 Pages

  16. CM-700d/600d

    3 Pages

  17. cm-25cg

    2 Pages

  18. cm-m6

    2 Pages

  19. DTS140 NVIS

    6 Pages

  20. LumiCam 2400

    4 Pages

  21. CM-25cG

    4 Pages

  22. FD-9

    6 Pages

  23. CR-20

    2 Pages

  24. CR-10 Plus

    2 Pages

  25. LCS IV

    1 Pages

  26. ISP40

    4 Pages

  27. LGS 1000

    4 Pages

  28. LGS 350

    8 Pages

  29. ISP 500

    4 Pages

  30. ISP 2000

    2 Pages

  31. ISP 150L

    2 Pages

  32. ISP 1000

    4 Pages

  33. LED-81X/-850

    4 Pages

  34. ACS-530

    4 Pages

  35. LED 25

    4 Pages

  36. LSM 350

    4 Pages

  37. LUMICAM 1300

    8 Pages

  38. CAS 140CTS

    4 Pages

  39. MAS 40

    8 Pages

  40. SPECTRO 320

    12 Pages