Group: Konica Minolta
Catalog excerpts
System Diagram Cell CM-A97 (2 mm Optional accessories Plastic Cell Plastic Cell Plastic Cell CM-A130 CM-A131 CM-A132 (2 mm set for 100) (10 mm set for 100) (20 mm set for 100) Personal Computer Transmittance Specimen Glass Cell Holder CM-A96 CM-A97/CM-A98/CM-A99 Transmittance Zero Calibration Plate CM-A100 Transmittance Specimen Holder CM-A96 Standard accessories Transmittance Zero Color Tiles (14 colors) Calibration Plate CM-A100 White Calibration Plate Zero Calibration Box CM-A154 CM-A155 Optional accessories Accessory Case CM-A156 Color Tiles (14 colors) Specifications Measuring geometry Detector Wavelength range Wavelength pitch Half bandwidth Photometric range Light source Minimum measurement interval Illumination/measurement area di:8º, de:8º (diffuse illumination/8º viewing angle) SCI (specular component included)/SCE (specular component excluded) switchable Conforms to CIE No.15, ISO 7724/1, ASTM E 1164, DIN 5033 Teil 7 and JIS Z 8722 condition c standard. Transmittance di:0º, de:0º (diffuse illumination/0º viewing angle) Conforms to CIE No.15, ASTM E 1164, DIN 5033 Teil 7 and JIS Z 8722 condition g standard. Silicon photodiode array with flat holographic grating 360 to 740 nm 10 nm Approx. 14 nm average 0 to 200%; Resolution: 0.001% Pulsed xenon arc lamp 3 seconds Reflectance: Changeable between SAV, MAV, and LAV SAV : 5x7 mm illumination / 3x5 mm measurement MAV : ø11 mm illumination / ø8 mm measurement LAV : ø28 mm illumination / ø25.4 mm measurement Transmittance: ø25 mm / Approx. ø20 mm Repeatability When white calibration plate is measured 30 times at 10-sec. intervals after white calibration has been performed: Spectral reflectance: Standard deviation within 0.05% Chromaticity: Standard deviation within E*ab 0.005 When black tile (BCRA Series II; reflectance: 1%) is measured 30 times at 10-second intervals after white calibration has been performed: Spectral reflectance: 380 to 740 nm: Standard deviation within 0.02% 360 and 370 nm: Standard deviation within 0.04% Chromaticity: Standard deviation within E*ab 0.05 Inter-instrument agreement Mean E*ab 0.08 (typical) Average for 12 BCRA Series II color tiles. Max E*ab 0.3 (corresponds to approx. E*CMC 0.2) for any of 12 BCRA Series II color tiles compared to values measured with Konica Minolta master body. UV adjustment Computer controlled: continuously variable Transmittance chamber Maximum sample thickness: Approx. 50 mm Maximum sample length: Unlimited (no sides when transmittance chamber cover is open) Sample holder (optional) for holding sheet samples or containers of liquid samples can be installed/removed Interface USB 1.1 Power AC 100 to 240 V 50/60 Hz 25 VA (using included AC adapter) Operation temperature/ 13 to 33º C, relative humidity 80% or less (at 33º C) with no condensation humidity range (*1) Storage temperature/ 0 to 40º C, relative humidity 80% or less (at 35º C) with no condensation humidity range Dimensions (W x H x D) 271 x 274 x 500 mm (10-11/16 x 10-3/4 x 19-11/16 in.) Weight 18 kg (39.7 lb.) Konica Minolta's flagship model: High accuracy and repeatability even at low reflectance/transmittance SpectraMagic™ NX enables you to perform comprehensive color inspection and analysis of incoming raw materials, in-process production, and outbound color-critical goods and materials in virtually any industry. With SpectraMagic™ NX you can insert digital images with measured data. Measure samples in any of 8 universally accepted color spaces. Select from 16 illuminants, and up to 40 indices to determine specific color and appearance properties, such as strength, brightness, haze, yellowness, opacity and whiteness. You can even configure up to 8 customized color equations. Reports range from simple Pass/Fail to trend charts, histograms, color plots, and spectral graphs. SpectraMagic™ NX comes with predefined templates, or you can create your own templates. For illustrations and explanations to understanding color and color measurement technology, there is a link to Konica Minolta's wellknown and respected “Precise Color Communication”, as well as step by step navigation help. Available in 7 languages: English, French, German, Italian, Spanish, Japanese, and Chinese (Simplified/Traditional) ® * Windows is a trademark of Microsoft Corporation in the USA and other countries. Worldwide sales network : Main service facilities *1 Operating temperature/humidity range of products for North America : 13 to 33º C, relative humidity 80% or less (at 31º C) with no condensation ● The specifications and drawings given here are subject to change without prior notice. ● Company names and product names used herein are trademarks or registered trademarks of their respective companies. ● KONICA MINOLTA and the Konica Minolta logo and the symbol mark, and "The essentials of imaging" are registered trademarks or trademarks of KONICA MINOLTA HOLDINGS, INC. SpectraMagic™ is a registered trademark of KONICA MINOLTA SENSING, INC. ©2011 KONICA MINOLTA SENSING, INC. SAFETY PRECAUTIONS For correct use and for your safety, be sure to read the instruction manual before using the instrument. Always connect the instrument to the specified power supply voltage. Improper connection may cause a fire or electric shock. Certificate No : LRQ 0960094/A Registration Date : March 3, 1995 Certificate No : JQA-E-80027 Registration Date : March 12, 1997 9242-4851-32 BBJAPK 1 Printed in Japan
Open the catalog to page 1An advanced spectrophotometer for reflectance and transmittance measurements of a broad range of subjects including pigments, dyes, plastic, textiles, paints, ceramics, etc. With its high accuracy, high repeatability, and high reliability, the CM-3700A can be used as the top standard instrument to which other instruments are referenced in color quality control systems including multiple instruments, both within a company or between companies. Konica Minolta's advanced optical, sensing, and signalprocessing technology provide excellent repeatability. Strictly selected highquality parts...
Open the catalog to page 2All Konica Minolta Sensing Americas catalogs and technical brochures
-
LumiTop Series
16 Pages
-
LumiSuite
8 Pages
-
CAS140D_IR
2 Pages
-
CAS140CT_IR
8 Pages
-
CAS125
4 Pages
-
LumiCam 4000B_2400B_V2
12 Pages
-
ISP Series
16 Pages
-
DTS 140D NVIS
5 Pages
-
ACS & ACU Series
12 Pages
-
Spectrophotometer CM-36dG
8 Pages
-
LGS 650
8 Pages
-
LumiCam Series
16 Pages
-
CAS 120
8 Pages
-
CAS 140D
16 Pages
-
New GM series gloss
4 Pages
-
Spectrophotometer CM-5
3 Pages
-
SPECTROPHOTOMETER CM-3700A
3 Pages
-
CRI Illuminance Meter CL-70F
2 Pages
-
Chroma Meter CS-150
3 Pages
-
CHROMA METER CS-200
6 Pages
-
Chroma Meter CL-200A
4 Pages
-
2D Color Analyzer CA-2500
8 Pages
-
Skin Analysis Software CM-SA
4 Pages
-
GTI GLE-M
2 Pages
-
GTI MiniMatcher Series
2 Pages
-
Rhopoint TAMS™
6 Pages
-
Rhopoint IQ FLEX 20
2 Pages
-
Uni Gloss 60A/S/CT
4 Pages
-
BC-10 Plus
4 Pages
-
CR-410PB
4 Pages
-
CR-400/410
5 Pages
-
CM-3700A
3 Pages
-
CM-700d/600d
3 Pages
-
cm-25cg
2 Pages
-
cm-m6
2 Pages
-
DTS140 NVIS
6 Pages
-
Rhopoint IQ-S
4 Pages
-
RHOPTOINT instruments
6 Pages
-
LumiCam 2400
4 Pages
-
Medidor de Brillo 268A
4 Pages
-
CM-25cG
4 Pages
-
FD-9
6 Pages
-
RHOPOINT Flex 60 / Flex 20
2 Pages
-
CR-20
2 Pages
-
CR-10 Plus
2 Pages
-
ISP Series Integrating Spheres
17 Pages
-
LCS IV
1 Pages
-
ISP40
4 Pages
-
LGS 1000
4 Pages
-
LGS 350
8 Pages
-
ISP 500
4 Pages
-
ISP 2000
2 Pages
-
ISP 150L
2 Pages
-
ISP 1000
4 Pages
-
LEDGON LED GONIOPHOTOMETER
4 Pages
-
LED-81X/-850
4 Pages
-
ACS-530
4 Pages
-
LED 25
4 Pages
-
LSM 350
4 Pages
-
DTS 500 SPECTRORADIOMETER
8 Pages
-
THE DTS 400 SYSTEM
2 Pages
-
LUMICAM 1300
8 Pages
-
CAS 140CTS
4 Pages
-
MAS 40
8 Pages
-
SPECTRO 320
12 Pages
-
MM-4E CONTROLLED LIGHTING
2 Pages
-
CM-600D SPECTROPHOTOMETER
3 Pages
-
CR-410C Coffee
2 Pages
-
Chlorophyll Meter SPAD-502
2 Pages
-
MULTI GLOSS 268PLUS
2 Pages
-
CM-SA SKIN ANALYSIS SOFTWARE
4 Pages
-
CM-5 SPECTROPHOTOMETER
3 Pages