Main Specifications Model Measurement geometry Size of measurement spot Standard compliance Measurement range Resolution Repeatability Inter-instrument agreement Memory Difference measurement Battery performance Measurement time Auto power off Languages Measurement mode Interface Operation temperature/ humidity range Storage temperature/humidity range Power Size (W x H x D) Weight Display Software MULTI GLOSS 268A UNI GLOSS 60A UNI GLOSS 60S UNI GLOSS 60CT 20°, 60°, 85° 60° 60° 60° 20° : 10 × 10 mm 60° : 9 × 15 mm 60° : 9 × 15 mm 60° : 2 × 4 mm 60° : 9 × 15 mm 85° : 5 × 38 mm ISO 2813, ASTM D 523, ASTM D 2457, DIN 67530, ISO 7668 (excluding UNI GLOSS 60S), JIS Z 8741 (excluding UNI GLOSS 60S) 20° : 0.0 to 2,000 GU 60° : 0.0 to 1,000 GU 60° : 0.0 to 1,000 GU 60° : 0.0 to 1,000 GU 60° : 0.0 to 1,000 GU 85° : 0.0 to 160 GU 0.0 to 99.9 GU : 0.1 GU 100 to 2,000 GU : 1 GU 0.0 to 19.9 GU : 0.1 GU 0.0 to 99.9 GU : 0.2 GU 20.0 to 99.9 GU : 0.2 GU 100 to 2,000 GU : 0.2% of reading 100 to 2,000 GU : 0.2% of reading 0.0 to 19.9 GU : 0.2 GU 0.0 to 99.9 GU : 0.5 GU 20.0 to 99.9 GU : 0.5 GU 100 to 2,000 GU : 0.5% of reading 100 to 2,000 GU : 0.5% of reading 999 measurements with date and time Memory for 50 standard Approx. 4,000 measurements (when using 1.5 V AA (R6) size alkaline battery) 0.5 seconds 10 to 99 seconds selectable English, Spanish, German, French, Italian, Russian, Polish, Portuguese, Turkish, Japanese Normal mode (Sample mode, Statistics, Continuous, Basic mode); Difference mode USB 2.0 高精度・安定性に優れた 分光放射輝度計の最上位モデル 15 to 40°C relative humidity max. 85% (at 35°C) with no condensation -10 to 60°C relative humidity max. 85% (at 35°C) with no condensation 1.5 V AA (R6) size alkaline battery, or via USB-port of PC 155 × 73 × 48 mm 400 g Color LCD smart-chart (smart-lab Gloss) System Diagram Standard Accessories Optional Accessories * Downloadable from Konica Minolta website USB Cable GM-A104 PC (commercially available) Carrying Case GM-A111 MULTI GLOSS 268A UNI GLOSS 60A/60S/60CT Hand Strap GM-A106 1.5 V AA (R6) size alkaline battery • KONICA MINOLTA, the Konica Minolta logo and symbol mark, and “Giving Shape to Ideas” are registered trademark or trademarks of Konica Minolta, Inc. • Displays shown are for illustration purpose only. • The specifications and appearance shown herein are subject to change without notice. GM-A92 Checking Standard for MULTI GLOSS 268A (Total of 4 tiles: Individual-angle semi-gloss tiles; Combined 20°/60°/85° high-gloss tile) GM-A94 Checking Standard for UNI GLOSS 60A (Total of 2 tiles: 60° semi-gloss tile; 60° high-gloss tile) GM-A112 Checking Standard for UNI GLOSS 60CT (Total of 2 tiles: 60° semi-gloss tile; 60° high-gloss tile) Gloss Data Software smart-chart GM-A95 Checking Standard Mirror (Total of 4 tiles: Individual-angle semi-gloss tiles; Combined 20°/60°/85° high-gloss tile) SAFETY PRECAUTIONS For correct use and for your safety, be sure to read the instruction manual before using the instrument. ●Be sure to use the specified batteries. Using improper batteries may cause a fire or electric shock. Certificate No.: JQA-QMA15888 Registration Date : October 26, 2018 Certificate No : JQA-E-80027 Registration Date : March 12, 1997 KONICA MINOLTA, Inc., Sakai Site KONICA MINOLTA, Inc., Sakai Site Product design, manufacture/manufacturing management, calibration, and service New GM series gloss meters offer even higher versatility !
Open the catalog to page 1■MULTI GLOSS 268A (Measurement geometry: 20°, 60°, 85°; Successor to MULTI GLOSS 268Plus) ■UNI GLOSS 60S (Measurement geometry: 60°) Small aperture model With high measurement accuracy at low gloss levels, this model is suitable when multiple glossmeters are used in your company or between your company and suppliers or customers. It can be used for measuring the interior parts of cars, etc. The small measurement area of 2 mm x 4 mm is suitable for measuring minute areas or curved surfaces. ■UNIL GLOSS 60A (Measurement geometry: 60°; Successor to UNI GLOSS 60Plus) ■UNI GLOSS 60CT (Measurement...
Open the catalog to page 2■MULTI GLOSS 268A (Measurement geometry: 20°, 60°, 85°; Successor to MULTI GLOSS 268Plus) ■UNI GLOSS 60S (Measurement geometry: 60°) Small aperture model With high measurement accuracy at low gloss levels, this model is suitable when multiple glossmeters are used in your company or between your company and suppliers or customers. It can be used for measuring the interior parts of cars, etc. The small measurement area of 2 mm x 4 mm is suitable for measuring minute areas or curved surfaces. ■UNIL GLOSS 60A (Measurement geometry: 60°; Successor to UNI GLOSS 60Plus) ■UNI GLOSS 60CT (Measurement...
Open the catalog to page 3System Diagram • KONICA MINOLTA, the Konica Minolta logo and symbol mark, and "Giving Shape to Ideas" are registered trademark or trademarks of Konica Minolta, Inc. • Displays shown are for illustration purpose only. • The specifications and appearance shown herein are subject to change without notice. KONICA MINOLTA, INC. Konica Minolta Sensing Americas, Inc. Konica Minolta Sensing Europe B.V. Konica Minolta (CHINA) Investment Ltd. Konica Minolta Sensing Singapore Pte Ltd. Konica Minolta Sensing Korea Co., Ltd. SAFETY PRECAUTIONS Osaka, Japan New Jersey, U.S.A. European Headquarter/BENELUX German...
Open the catalog to page 42 Pages
16 Pages
8 Pages
2 Pages
8 Pages
4 Pages
12 Pages
16 Pages
5 Pages
12 Pages
8 Pages
8 Pages
16 Pages
8 Pages
16 Pages
3 Pages
3 Pages
2 Pages
3 Pages
6 Pages
4 Pages
8 Pages
4 Pages
2 Pages
2 Pages
6 Pages
2 Pages
4 Pages
4 Pages
4 Pages
5 Pages
3 Pages
3 Pages
2 Pages
2 Pages
6 Pages
4 Pages
6 Pages
4 Pages
4 Pages
4 Pages
6 Pages
2 Pages
2 Pages
2 Pages
3 Pages
17 Pages
1 Page
4 Pages
4 Pages
8 Pages
4 Pages
2 Pages
2 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
8 Pages
2 Pages
8 Pages
4 Pages
8 Pages
12 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
3 Pages