ILLUMINANCE METER LUMINANCE METER CHROMA METER

Open the catalog to page 1
Light Meters - 2

illuminance Measurement Trio Illuminance Meter Main Features Compatible with new, next-generation light sources including PWM-controlled sources. For simple but accurate illuminance measurements. Makes creating illuminance measurement systems such as multi-point measurement systems easy! Reliable, worry-free illuminance meters that conform to JIS AA Class and DIN Class B Illuminance Meters T-10A and T-10MA conform to Class AA of JIS C 1609-1: 2006 "Illuminance meters Part 1: General measuring instruments" and DIN 5032 Part 7 Class-B " Photometry; classification of illuminance meters and...

Open the catalog to page 2
Light Meters - 3

⿎⿎System diagram Data management using computer Convenient, easy-to-use Excel® add-in software Reads measurement data from T-10A series Illuminance Meters directly into Excel®. Further processing of data can then be performed easily using the various functions of Excel®. Data Management software Personal computer (Commercial product) For multi-point and cable extension measurement Adapter Unit for Receptor Head (Including T-A15) receptor head Strap RS-232C Printer (Commercial product) Adapter Unit for Main Body Custom order Data recording using printer Case T-10MA receptor head T-10WSA...

Open the catalog to page 3
Light Meters - 4

illuminance Measurement Trio Chroma Meter r colo res ture! su Meampera te De facto industry standard for measuring color temperature! Can also measure illuminance (JIS AA class) Main Features Compact and easy to carry Excel® add-in software included Data Management Software CL-S10w The CL-200A's compact body fits in your palm. Battery-powered so it can be taken along and used anywhere. (Standard accessory) Application examples For lighting production and adjustment When using various types of light sources in a room or open space, it is sometimes necessary to check the color of the...

Open the catalog to page 4
Light Meters - 5

⿎⿎System diagram Measurement accuracies of CL-200A and photographic color meter When measuring light sources with non-continuous spectrums such as LEDs, etc., accurate illumination color temperature is particularly required. The CL-200A can measure color temperature accurately. Data Management Software CL-S10w Hood CL-A11 Printer Cable T-A12 (2m) External Power Photographic color meter ⿎⿎Main specifications of Chroma Meter CL-200A Other function Measuring range Color temperature and correlated color temperature Color temperature When an ideal blackbody* is heated, it begins to emit light,...

Open the catalog to page 5
Light Meters - 6

illuminance Measurement Trio Illuminance Spectrophotometer Data Management Software CL-S10w (Standard accessory) For evaluation of high-class nextgeneration lamps such as LED illumination and EL illumination Convenient, easy-to-use Excel® add-in software Reads measurement data from the CL-500A directly into Excel®. Further processing of data can then be performed easily using the various functions of Excel®. Spectral irradiance waveform display Since peak wavelengths can be seen easily, classification and grading of light sources can be performed easily at high accuracy. In addition,...

Open the catalog to page 6
Light Meters - 7

⿎⿎System diagram Standard Accessories Since long ago, man has compared colors by arranging objects side-by-side and looking at them under natural light (sunlight). Although torches, candles, incandescent lamps and other light sources are also used for illumination, it has always been the standard practice to compare colors under natural light. In addition to fluorescent lamps, LEDs (light emitting diodes) have recently been adopted as illuminating lamps. When comparing how these new types of lamps make objects look against how natural light makes them look, how closely the appearances match...

Open the catalog to page 7
Light Meters - 8

Luminance Meters LS-100/LS-110 Compact, lightweight, easy-to-use SLR luminance meters with a wide measuring range Luminance Meter LS-100 1° acceptance angle, Measuring range: 0.001 to 299,900 cd/m2 (0.001 to 87,530 fL) 1/3° acceptance angle, Measuring range: 0.01 to 999,900 cd/m2 (0.01 to 291,800 fL) Main Features Narrow acceptance angle for measurements of small specimens Acceptance angles of only 1° for LS-100 and 1/3° for LS110 allow accurate measurements of small specimen areas. In addition, optional close-up lenses can be used to measure areas as small as ø1.3 mm when using LS-100 and...

Open the catalog to page 8
Light Meters - 9

Chroma Meter Model Type Measuring angle Optical system Angle of view Focusing distance Receptors Spectral response A compact, lightweight, battery-powered instrument with a 1° measurement angle for high-accuracy non-contact measurements of the luminance and chromaticity of light sources and reflective subjects Response time Luminance units Measuring range*1 Accuracy*2 Repeatability*1 Target value Measurement modes Display E a s y - To - R e a d D i s p l a y Viewfinder Image Measuring area (1°) Field of view (9°) Measured luminance (cd/m 2 or fL) External display Main Applications...

Open the catalog to page 9
Light Meters - 10

Chroma Meter Data Management Software CS-S10w Standard (Standard accessory) CS-S10w Standard Edition allows users to control the CS-200 with a PC to display the list of measured data or to transfer the data to spreadsheet software. Main Features Perfect match of the spectral response to the CIE color-matching functions Spectral response of conventional tristimulus colorimeters Relative sensitivity Relative sensitivity Konica Minolta’s newly-developed spectral fitting method provides tristimulus values (XYZ = red, green, blue) with significantly higher accuracy than that of conventional...

Open the catalog to page 10
Light Meters - 11

KONICA MINOLTA SAFETY PRECAUTIONS For correct use and for your safety, be sure to read the instruction manual before using the instrument. A• Always connect the instrument to the specified power supply voltage. Improper connection may cause a fire or electric shock. • Be sure to use the specified batteries. Using improper batteries may cause a fire or electric shock. •KONICA MINOLTA and the Konica Minolta logo and the symbol mark, and "Giving Shape to Ideas" are registered trademarks or trademarks of KONICA MINOLTA HOLDINGS,INC. •Windows® and Excel® are trademarks of Microsoft Corporation...

Open the catalog to page 11

All Konica Minolta Sensing Americas catalogs and technical brochures

  1. Light Meters

    24 Pages

  2. GTI GLE-M

    2 Pages

  3. BC-10 Plus

    4 Pages

  4. CR-410PB

    4 Pages

  5. CR-400/410

    5 Pages

  6. CM-3700A

    3 Pages

  7. cm3600a

    3 Pages

  8. CM-2500c

    4 Pages

  9. CM-2600d

    8 Pages

  10. CM-700d/600d

    3 Pages

  11. cm-25cg

    2 Pages

  12. cm-m6

    2 Pages

  13. DTS140 NVIS

    6 Pages

  14. LumiCam 2400

    4 Pages

  15. Light Meters

    24 Pages

  16. CM-25cG

    4 Pages

  17. FD-9

    6 Pages

  18. Colibri®

    6 Pages

  19. CL-70F

    2 Pages

  20. CR-20

    2 Pages

  21. CR-10 Plus

    2 Pages

  22. LCS IV

    1 Pages

  23. CM-512m3

    3 Pages

  24. ISP40

    4 Pages

  25. LGS 1000

    4 Pages

  26. LGS 350

    8 Pages

  27. ISP 500

    4 Pages

  28. ISP 2000

    2 Pages

  29. ISP 150L

    2 Pages

  30. ISP 1000

    4 Pages

  31. LED-81X/-850

    4 Pages

  32. ACS-530

    4 Pages

  33. LED 25

    4 Pages

  34. LSM 350

    4 Pages

  35. LUMICAM 1300

    8 Pages

  36. CAS 140CTS

    4 Pages

  37. CAS 120

    8 Pages

  38. MAS 40

    8 Pages

  39. SPECTRO 320

    12 Pages

  40. COLIBRI

    6 Pages

  41. NC-1

    2 Pages

  42. light meter

    11 Pages

Archived catalogs

  1. CM-M6

    3 Pages

  2. VIVID 9i

    8 Pages

  3. Pulsox-2

    2 Pages

  4. VIVID 910

    6 Pages

  5. CA-100Plus

    4 Pages

  6. CM-2500c

    4 Pages

  7. CM-3700d

    3 Pages

  8. LCS-III

    4 Pages

  9. CR-400/410

    5 Pages