LGS 350
1 /8Pages

LGS 350

LGS 350
1 /8Pages

Catalog excerpts

LGS 350-1

We bring quality to light. light measurement

 Open the catalog to page 1
LGS 350-2

The features at a glance Type C goniophotometer with horizontal optical axis For samples up to max. 700 mm diameter and 8 kg weight Accurate determination of the luminous intensity distribution and luminous flux Angular-resolved analysis of spectral and colorimetric quantities Data export in IES and EULUMDAT format Perfect for mid-sized SSL light sources and LED modules The LGS 350 Goniophotometer/Goniospectroradiometer was developed for the analysis of angle-dependent spatial radiation properties from small to medium-sized SSL luminaires and lamps, and LED modules. The test specimen is operated...

 Open the catalog to page 2
LGS 350-3

The optical probe of the spectroradiometer or the photometer head for taking measurements is placed outside the photometric distance and attached to a stray light tube adjusted to the measuring distance and the sample size. The measuring distance should be 10 to 15 times the diameter of the light source being tested. The goniometer unit The LGS 350 Goniometer rotates the test specimen in the gamma and C axes. The horizontal alignment of the CIE 121-1996 coordinate system facilitates a particularly compact test setup. Both axes can be operated simultaneously and can be moved smoothly and with...

 Open the catalog to page 3
LGS 350-4

The full spectrum of measuring options The comprehensive accessories significantly expand the range of measuring options offered by the LGS 350. A universal sample holder for mid-size LED modules and lamps, and a lamp holder for standard fittings of the type E10, E27, E40, etc. are supplied. Sample holder with LED-870 test adapter for LED arrays and modules Photometric and colorimetric measurements Sample holder with LED-850 test adapter for single LEDs Sample holders for TEC test adapters of the LED-850 and LED-870 series are available to plug and go. The test adapters facilitate the analyis...

 Open the catalog to page 4
LGS 350-5

within a few minutes. Even pulse-width modulated LEDs with cycle frequencies of 80 Hz to 10 kHz can be measured precisely using the adaptive filtering and digital signal processing of the innovative DSP 10 Photometer. Measurement sequences in SpecWin Pro SpecWin Pro software powers the outstanding productivity of the LGS 350. Two measurement modes are supported. Firstly, the sequence mode allows spatial radiation patterns of the test specimen to be recorded for gamma and C axes in defined angular increments. All measured data are available for subsequent evaluations. Secondly, the test series...

 Open the catalog to page 5
LGS 350-6

Technical specifications Model Equipment setup Stable base with integrated LGS Controller Benchtop version with LGS Controller in a separate 19” rack 14 U in height; 10 U occupied, 4 U free 9 U in height, fully occupied, optionally more Height of the optical axis Goniometer CIE goniometer type Type C with horizontal optical axis Stepper motors Angular range C axis ±160° with end switches, -10° – 190° used for measurements Angular range γ axis Resolution of the angle encoder Angular speed C axis 16 speeds selectable from 2.5°/s to 36°/s Angular speed γ axis 16 speeds selectable from 1°/s to 18°/s...

 Open the catalog to page 6
LGS 350-7

Ordering information Order no. LGS 350 Goniometer with stable base; 2-axis goniometer in type C configuration with horizontal optical axis; integrated 19” rack for LGS Controller (includes stepper-motor control and space for another 2 modules); without photometer or spectroradiometer LGS 350 Goniometer in benchtop version; 2-axis goniometer in type C configuration with horizontal optical axis; separate 19” rack for LGS Controller (includes stepper-motor control and space for one further module); without photometer or spectroradiometer Optional 115 VAC power supply unit for LGS 350 Optional 19”...

 Open the catalog to page 7
LGS 350-8

We bring quality to light. light measurement Instrument Systems GmbH Neumarkter Str. 83 81673 Munich, Germany Tel.: +49 89 /45 49 43-0 Fax: +49 89 /45 49 43-11 E-mail: [email protected] www.instrumentsystems.com

 Open the catalog to page 8

All Konica Minolta Sensing Americas catalogs and technical brochures

  1. Specim SX25

    2  Pages

  2. LumiTop Series

    16  Pages

  3. LumiSuite

    8  Pages

  4. CAS140D_IR

    2  Pages

  5. CAS140CT_IR

    8  Pages

  6. CAS125

    4  Pages

  7. ISP Series

    16  Pages

  8. DTS 140D NVIS

    5  Pages

  9. LGS 650

    8  Pages

  10. LumiCam Series

    16  Pages

  11. CAS 120

    8  Pages

  12. CAS 140D

    16  Pages

  13. GTI GLE-M

    2  Pages

  14. BC-10 Plus

    4  Pages

  15. CR-410PB

    4  Pages

  16. CR-400/410

    5  Pages

  17. CM-3700A

    3  Pages

  18. CM-700d/600d

    3  Pages

  19. cm-25cg

    2  Pages

  20. cm-m6

    2  Pages

  21. DTS140 NVIS

    6  Pages

  22. Rhopoint IQ-S

    4  Pages

  23. LumiCam 2400

    4  Pages

  24. CM-25cG

    4  Pages

  25. FD-9

    6  Pages

  26. CR-20

    2  Pages

  27. CR-10 Plus

    2  Pages

  28. LCS IV

    1  Page

  29. ISP40

    4  Pages

  30. LGS 1000

    4  Pages

  31. ISP 500

    4  Pages

  32. ISP 2000

    2  Pages

  33. ISP 150L

    2  Pages

  34. ISP 1000

    4  Pages

  35. LED-81X/-850

    4  Pages

  36. ACS-530

    4  Pages

  37. LED 25

    4  Pages

  38. LSM 350

    4  Pages

  39. LUMICAM 1300

    8  Pages

  40. CAS 140CTS

    4  Pages

  41. MAS 40

    8  Pages

  42. SPECTRO 320

    12  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.