We bring quality to light. ISP 1000 Integrating Sphere for measuring radiant power and luminous flux Product highlights Measurement of total radiant power and total luminous flux of high-power LEDs, LED modules, and lamps Robust sample stage for mounting LED modules and SSL products Lamp post for measuring light sources positioned in an upright or suspended configuration 300 mm measurement port for launching light radiation from outside Auxiliary lamp to compensate for self-absorption The ISP 1000 has been designed with a diameter of one meter specifically for taking precise measurements of radiant power and luminous flux of the larger and more powerful light sources used for solid-state lighting applications and for lamps in general. Two geometries are defined according to the type of test specimen and the test data required: In the 4π configuration1, the samples are mounted inside the sphere, while in the 2π configuration2 the light radiation is launched from outside through a port in the side of the sphere wall. The innovative design of the ISP 1000 minimizes interference from baffles and ports and therefore permits more accurate measurements. The interior surface of the sphere is coated with barium sulfate (BaSO4) and has a reflectance of approximately 97%. The light radiation is guided through a detector port and an optical fiber to the spectrometer. All spectrometers supplied by Instrument Systems can be linked to the sphere. The ISP 1000 has a strong aluminum frame fitted with castors and can be opened completely. Light radiation is emitted in all directions Light radiation is only emitted forward (one hemisphere) light measurement
Open the catalog to page 1We bring quality to light. Sample stage Sample stage The internal sample stage is ideal for taking precise measurements of large LED modules. The platform of the sample stage measuring 200 x 200 mm is height-adjustable. This allows the test sample to be precisely positioned at the center of the sphere. The M5 threads at 50 mm centers provide secure fixing for the specimen in the desired position. Power supply and data control for the specimen is delivered conveniently through a 16-pole terminal strip. Lamp post ISP1000 opened with lamp post suspended The universal lamp post is available for...
Open the catalog to page 2We bring quality to light. Auxiliary lamp Temperature sensor The internal lamp post with the adapter for halogen lamps is necessary for spectral and absolute calibration of the ISP 1000. Instrument Systems also supplies a 50 W calibration lamp and precision power supply for customers who want to carry out their own recalibrations. This allows on-site calibrations without having to transport the sphere. Interference from baffles and sample holders that could compromise the measurement results were kept to a minimum when the ISP 1000 was designed. However, the influence exerted by the...
Open the catalog to page 3We bring quality to light. Data and technical specifications Spectral range Diameter of the measurement port Fiber bundle External dimensions (W, D, H), closed External dimensions (W, D, H), 90° open External dimensions (W, D, H), 180° open Power supply for the auxiliary lamp Ordering information Internal diameter Order number Integrating sphere with 1 m diameter; for measurement of luminous flux and radiant power at lamps, LEDs and LED modules. Hinges for opening and closing the sphere Barium sulfate coating Measurement port with 300 mm diameter for mounting the test specimen outside the...
Open the catalog to page 4All Konica Minolta Sensing Americas catalogs and technical brochures
-
LumiTop Series
16 Pages
-
LumiSuite
8 Pages
-
CAS140D_IR
2 Pages
-
CAS140CT_IR
8 Pages
-
CAS125
4 Pages
-
LumiCam 4000B_2400B_V2
12 Pages
-
ISP Series
16 Pages
-
DTS 140D NVIS
5 Pages
-
ACS & ACU Series
12 Pages
-
Spectrophotometer CM-36dG
8 Pages
-
LGS 650
8 Pages
-
LumiCam Series
16 Pages
-
CAS 120
8 Pages
-
CAS 140D
16 Pages
-
New GM series gloss
4 Pages
-
Spectrophotometer CM-5
3 Pages
-
SPECTROPHOTOMETER CM-3700A
3 Pages
-
CRI Illuminance Meter CL-70F
2 Pages
-
Chroma Meter CS-150
3 Pages
-
CHROMA METER CS-200
6 Pages
-
Chroma Meter CL-200A
4 Pages
-
2D Color Analyzer CA-2500
8 Pages
-
Skin Analysis Software CM-SA
4 Pages
-
GTI GLE-M
2 Pages
-
GTI MiniMatcher Series
2 Pages
-
Rhopoint TAMS™
6 Pages
-
Rhopoint IQ FLEX 20
2 Pages
-
Uni Gloss 60A/S/CT
4 Pages
-
BC-10 Plus
4 Pages
-
CR-410PB
4 Pages
-
CR-400/410
5 Pages
-
CM-3700A
3 Pages
-
CM-700d/600d
3 Pages
-
cm-25cg
2 Pages
-
cm-m6
2 Pages
-
DTS140 NVIS
6 Pages
-
Rhopoint IQ-S
4 Pages
-
RHOPTOINT instruments
6 Pages
-
LumiCam 2400
4 Pages
-
Medidor de Brillo 268A
4 Pages
-
CM-25cG
4 Pages
-
FD-9
6 Pages
-
RHOPOINT Flex 60 / Flex 20
2 Pages
-
CR-20
2 Pages
-
CR-10 Plus
2 Pages
-
ISP Series Integrating Spheres
17 Pages
-
LCS IV
1 Pages
-
ISP40
4 Pages
-
LGS 1000
4 Pages
-
LGS 350
8 Pages
-
ISP 500
4 Pages
-
ISP 2000
2 Pages
-
ISP 150L
2 Pages
-
LEDGON LED GONIOPHOTOMETER
4 Pages
-
LED-81X/-850
4 Pages
-
ACS-530
4 Pages
-
LED 25
4 Pages
-
LSM 350
4 Pages
-
DTS 500 SPECTRORADIOMETER
8 Pages
-
THE DTS 400 SYSTEM
2 Pages
-
LUMICAM 1300
8 Pages
-
CAS 140CTS
4 Pages
-
MAS 40
8 Pages
-
SPECTRO 320
12 Pages
-
MM-4E CONTROLLED LIGHTING
2 Pages
-
CM-600D SPECTROPHOTOMETER
3 Pages
-
CR-410C Coffee
2 Pages
-
Chlorophyll Meter SPAD-502
2 Pages
-
MULTI GLOSS 268PLUS
2 Pages
-
CM-SA SKIN ANALYSIS SOFTWARE
4 Pages
-
CM-5 SPECTROPHOTOMETER
3 Pages